A 13.2b optical proximity sensor system with 130klx ambient light rejection capable of heart rate and blood oximetry monitoring

Luca Sant, A. Fant, S. Stojanovic, S. Fabbro, J. Ceballos
{"title":"A 13.2b optical proximity sensor system with 130klx ambient light rejection capable of heart rate and blood oximetry monitoring","authors":"Luca Sant, A. Fant, S. Stojanovic, S. Fabbro, J. Ceballos","doi":"10.1109/ESSCIRC.2015.7313905","DOIUrl":null,"url":null,"abstract":"A system for measuring optical proximity based on reflection of modulated light is presented. Its novel input stage topology comprising an AC coupled TIA and a two stage DC rejection circuit based on a synthesized inductive impedance, provides readouts with a resolution better than 13.2 ENOB. This allows the sensor system to be used without modifications also for heart rate and blood oximetry monitoring.","PeriodicalId":11845,"journal":{"name":"ESSCIRC Conference 2015 - 41st European Solid-State Circuits Conference (ESSCIRC)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ESSCIRC Conference 2015 - 41st European Solid-State Circuits Conference (ESSCIRC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ESSCIRC.2015.7313905","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

Abstract

A system for measuring optical proximity based on reflection of modulated light is presented. Its novel input stage topology comprising an AC coupled TIA and a two stage DC rejection circuit based on a synthesized inductive impedance, provides readouts with a resolution better than 13.2 ENOB. This allows the sensor system to be used without modifications also for heart rate and blood oximetry monitoring.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
一种132b光学近距离传感器系统,具有130klx的环境光抑制能力,能够监测心率和血氧饱和度
提出了一种基于调制光反射的光学接近度测量系统。其新颖的输入级拓扑结构包括交流耦合TIA和基于合成电感阻抗的两级直流抑制电路,提供的读数分辨率优于13.2 ENOB。这使得传感器系统无需修改也可用于心率和血氧饱和度监测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Theoretical analyses and modeling for nanoelectronics A 66 dB SNDR pipelined split-ADC using class-AB residue amplifier with analog gain correction Suppression of VCO pulling effects using even-harmonic quiet transmitting circuits A 6-bit 10-GS/s 63-mW 4x TI time-domain interpolating flash ADC in 65-nm CMOS A 0.01 mm2 fully-differential 2-stage amplifier with reference-free CMFB using an architecture-switching-scheme for bandwidth variation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1