{"title":"A validated stability-indicating HPLC assay method for Meclizine HCl in bulk drug","authors":"M. Ubale, M. Shioorkar, V. Choudhari","doi":"10.7439/IJAPA.V6I3.3855","DOIUrl":null,"url":null,"abstract":"An isocratic reversed phase stability-indicating high-performance liquid chromatographic (HPLC) assay method was developed and validated for quantitative determination of Meclizine HCl in bulk drugs. An isocratic, reversed phase HPLC method was developed to separate the drug from the degradation products, using a Water Nova Pack C18 (250 x 4.6) mm, 5? column and the mobile phase containing 1.0 gm Sodium dihydrogen phosphate and 1.0 gm 1-octaneSulfonic acid salt in 1000ml water filter and mixed. Prepare a homogenous mixture of buffer, methanol and acetonitile. The detection was carried out at wavelength 264 nm. The developed method was validated with respect to linearity, accuracy (recovery), precision, system suitability, selectivity, robustness prove the stability indicating ability of the method.","PeriodicalId":14317,"journal":{"name":"International Journal of Pharmaceutical Chemistry","volume":"66 1","pages":"16-20"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Pharmaceutical Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7439/IJAPA.V6I3.3855","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
An isocratic reversed phase stability-indicating high-performance liquid chromatographic (HPLC) assay method was developed and validated for quantitative determination of Meclizine HCl in bulk drugs. An isocratic, reversed phase HPLC method was developed to separate the drug from the degradation products, using a Water Nova Pack C18 (250 x 4.6) mm, 5? column and the mobile phase containing 1.0 gm Sodium dihydrogen phosphate and 1.0 gm 1-octaneSulfonic acid salt in 1000ml water filter and mixed. Prepare a homogenous mixture of buffer, methanol and acetonitile. The detection was carried out at wavelength 264 nm. The developed method was validated with respect to linearity, accuracy (recovery), precision, system suitability, selectivity, robustness prove the stability indicating ability of the method.