{"title":"LCL-filter design for grid-connected inverter to suppress grid-induced low-order current harmonics","authors":"Jinming Xu, Shaojun Xie, Jiarong Kan","doi":"10.1109/ECCE.2015.7309824","DOIUrl":null,"url":null,"abstract":"For grid-connected inverter, an LCL-type filter is widely used to suppress switching harmonics, and the capacitor current feedback is used to suppress the LCL resonance. In the published literatures, the relation among LCL parameters, capacitor current feedback and resonance damping was discussed; however, their relation with the low-order current distortion was not seriously considered. Considering that the main objective of using the LCL-type filter is to fulfill the current quality standard, the optimized design of LCL-type filter for low-order current harmonic suppression is deeply discussed in this paper. It is demonstrated that the suppression of grid-induced low-order current harmonics is closely related to the LCL parameters. On the basis of selecting the inverter-side inductance according to the switching ripple requirement of inverter-side current, the rest two parameters including the capacitance and the grid-side inductance are designed to enhance the low-order current harmonic suppression. Finally, two sets of LCL parameters are tested in this study, one of which is obtained by the proposed design procedure. Experimental results have demonstrated a good grid current quality under a distorted grid.","PeriodicalId":6654,"journal":{"name":"2015 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"26 1","pages":"1178-1183"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2015.7309824","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

For grid-connected inverter, an LCL-type filter is widely used to suppress switching harmonics, and the capacitor current feedback is used to suppress the LCL resonance. In the published literatures, the relation among LCL parameters, capacitor current feedback and resonance damping was discussed; however, their relation with the low-order current distortion was not seriously considered. Considering that the main objective of using the LCL-type filter is to fulfill the current quality standard, the optimized design of LCL-type filter for low-order current harmonic suppression is deeply discussed in this paper. It is demonstrated that the suppression of grid-induced low-order current harmonics is closely related to the LCL parameters. On the basis of selecting the inverter-side inductance according to the switching ripple requirement of inverter-side current, the rest two parameters including the capacitance and the grid-side inductance are designed to enhance the low-order current harmonic suppression. Finally, two sets of LCL parameters are tested in this study, one of which is obtained by the proposed design procedure. Experimental results have demonstrated a good grid current quality under a distorted grid.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
并网逆变器低阶电流谐波抑制的lc滤波器设计
对于并网逆变器,广泛采用LCL型滤波器来抑制开关谐波,采用电容电流反馈来抑制LCL谐振。在已发表的文献中,讨论了LCL参数、电容电流反馈和谐振阻尼之间的关系;然而,它们与低阶电流畸变的关系没有得到认真考虑。考虑到使用低阶电流谐波滤波器的主要目的是满足电流质量标准,本文对低阶电流谐波滤波器的优化设计进行了深入的讨论。结果表明,电网诱发的低次电流谐波的抑制与LCL参数密切相关。在根据逆变侧电流的开关纹波要求选择逆变侧电感的基础上,设计电容和电网侧电感两个参数来增强对低次电流谐波的抑制作用。最后,本研究对两组LCL参数进行了测试,其中一组参数由所提出的设计程序获得。实验结果表明,在畸变栅格下具有良好的栅格电流质量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Accuracy comparison between Gompertz and polynomial based PV models Grid synchronization for a virtual direct power-controlled DFIG wind power system Enhancement on capacitor-voltage-balancing capability of a modular multilevel cascade inverter for medium-voltage synchronous-motor drives State observer for sensorless control of a grid-connected converter equipped with an LCL filter: Direct discrete-time design Multi-tap transformer topologies for improved tolerance against misalignment in inductive power transfer systems for electric vehicles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1