Yevgeniy L. Trykov, A. A. Kudryaev, Konstantin I. Kotsoyev, A. Ananyev
{"title":"Efficient method for the global noise filtering in measuring channels of the VVER NPP leak monitoring systems","authors":"Yevgeniy L. Trykov, A. A. Kudryaev, Konstantin I. Kotsoyev, A. Ananyev","doi":"10.3897/NUCET.7.65446","DOIUrl":null,"url":null,"abstract":"In accordance with Ref. (GOST R 58328-2018 “Pipelines of Nuclear Power Plants. Leak Before Break Concept”), NPPs with VVER-1200 reactors operate an acoustic leak monitoring system (ALMS) and a humidity leak monitoring system (HLMS), each performing the leak monitoring functions locally, independently of the other. The diagnostics results are conveyed to the upper level control system (LCS) to be further displayed for the main control room (MCR) operating personnel. There is also an integrated diagnostics system (IDS) intended to confirm the diagnosis and to update the leak rate values and coordinates based on analyzing the leak monitoring system readings and I&C signals. The system measuring channel readings are composed of background noise, the source for which are processes on the part of the reactor facility’s key components and auxiliary systems, and the leak signal in response to the leak occurrence. A major factor that affects the capability of leak monitoring systems to detect the leak is the quality of the background noise filtering. A new efficient global noise filtering method is proposed for being used as part of the integrated diagnostics system (IDS).","PeriodicalId":100969,"journal":{"name":"Nuclear Energy and Technology","volume":"42 1","pages":"67-72"},"PeriodicalIF":0.0000,"publicationDate":"2021-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Energy and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3897/NUCET.7.65446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In accordance with Ref. (GOST R 58328-2018 “Pipelines of Nuclear Power Plants. Leak Before Break Concept”), NPPs with VVER-1200 reactors operate an acoustic leak monitoring system (ALMS) and a humidity leak monitoring system (HLMS), each performing the leak monitoring functions locally, independently of the other. The diagnostics results are conveyed to the upper level control system (LCS) to be further displayed for the main control room (MCR) operating personnel. There is also an integrated diagnostics system (IDS) intended to confirm the diagnosis and to update the leak rate values and coordinates based on analyzing the leak monitoring system readings and I&C signals. The system measuring channel readings are composed of background noise, the source for which are processes on the part of the reactor facility’s key components and auxiliary systems, and the leak signal in response to the leak occurrence. A major factor that affects the capability of leak monitoring systems to detect the leak is the quality of the background noise filtering. A new efficient global noise filtering method is proposed for being used as part of the integrated diagnostics system (IDS).
根据参考(GOST R 58328-2018)“核电站管道”。VVER-1200反应堆的核电站运行一个声学泄漏监测系统(ALMS)和一个湿度泄漏监测系统(HLMS),每个系统在本地执行泄漏监测功能,彼此独立。诊断结果被传送到上层控制系统(LCS),进一步显示给主控制室(MCR)操作人员。还有一个综合诊断系统(IDS),用于确认诊断,并根据分析泄漏监测系统读数和I&C信号更新泄漏率值和坐标。该系统测量通道读数由背景噪声和响应泄漏发生的泄漏信号组成。背景噪声的来源是反应堆设施关键部件和辅助系统的过程。影响泄漏监测系统检测泄漏能力的一个主要因素是背景噪声滤波的质量。提出了一种新的有效的全局噪声滤波方法,用于综合诊断系统(IDS)。