A Comparative Study of Lateral Load Analysis Considering Two BNBC Codes Using ETABS Software

F. Abdullah, Z. Islam, M. Asif, Sumon Ali
{"title":"A Comparative Study of Lateral Load Analysis Considering Two BNBC Codes Using ETABS Software","authors":"F. Abdullah, Z. Islam, M. Asif, Sumon Ali","doi":"10.11648/J.AJCE.20210904.13","DOIUrl":null,"url":null,"abstract":"The Bangladesh National Building Code (BNBC) specifies and regulates the general specifications for structural, architecture and design parameters in Bangladesh. In the last three decades, Civil Engineering techniques, knowledge and materials as well as design parameters have been modified as per requirement. As a consequence, BNBC 2010 was written to reflect the transition. In this study, a systematic and parametric structural analysis of a ten-story residential building was analyzed (ETABS 16.0.2 software) by using BNBC 1993 and BNBC 2020 for four different locations (Patuakhali, Chandpur, Rangpur and Moulovibazar) suited in several zones to demonstrate how lateral load affects structural analysis and design of high rise infrastructure. The decision making parameters for structural analysis and design are tremor and wind forces, story drift, wind and seismic shear, moment of unique beams and columns, and base shear for seismic forces according to BNBC 2020 vary significantly compared to BNBC 1993. In this study, the earthquake load varies from 7.42% to 59.78%, while wind force ranges from 19.16% to 36.14% in the x-direction and 49.51% to 63.78% for y-direction, and story drift for earthquake load ranges from 47.96% to 51.27% and for wind load ranges from 29.89% to 34.45%. The comparison of the aforesaid design parameters is depicted graphically, and relevant tables are presented in this research article. In comparison to BNBC 1993, the requirements of BNBC 2020 usually result in a less cost-effective design with a higher safety margin.","PeriodicalId":7606,"journal":{"name":"American Journal of Civil Engineering","volume":"22 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Civil Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11648/J.AJCE.20210904.13","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

The Bangladesh National Building Code (BNBC) specifies and regulates the general specifications for structural, architecture and design parameters in Bangladesh. In the last three decades, Civil Engineering techniques, knowledge and materials as well as design parameters have been modified as per requirement. As a consequence, BNBC 2010 was written to reflect the transition. In this study, a systematic and parametric structural analysis of a ten-story residential building was analyzed (ETABS 16.0.2 software) by using BNBC 1993 and BNBC 2020 for four different locations (Patuakhali, Chandpur, Rangpur and Moulovibazar) suited in several zones to demonstrate how lateral load affects structural analysis and design of high rise infrastructure. The decision making parameters for structural analysis and design are tremor and wind forces, story drift, wind and seismic shear, moment of unique beams and columns, and base shear for seismic forces according to BNBC 2020 vary significantly compared to BNBC 1993. In this study, the earthquake load varies from 7.42% to 59.78%, while wind force ranges from 19.16% to 36.14% in the x-direction and 49.51% to 63.78% for y-direction, and story drift for earthquake load ranges from 47.96% to 51.27% and for wind load ranges from 29.89% to 34.45%. The comparison of the aforesaid design parameters is depicted graphically, and relevant tables are presented in this research article. In comparison to BNBC 1993, the requirements of BNBC 2020 usually result in a less cost-effective design with a higher safety margin.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
基于ETABS软件的两种BNBC规范横向荷载分析的比较研究
孟加拉国国家建筑规范(BNBC)规定和规范了孟加拉国的结构、建筑和设计参数的一般规范。在过去的三十年中,土木工程技术、知识和材料以及设计参数都根据要求进行了修改。因此,BNBC 2010的编写反映了这种转变。在本研究中,使用BNBC 1993和BNBC 2020软件(ETABS 16.0.2软件)对一栋十层住宅楼进行了系统和参数化结构分析,分析了适合于几个区域的四个不同地点(Patuakhali、Chandpur、Rangpur和Moulovibazar),以展示横向荷载如何影响高层基础设施的结构分析和设计。根据BNBC 2020,结构分析和设计的决策参数是震动和风力,楼层漂移,风和地震剪力,独特的梁和柱的弯矩,地震力的基础剪力,与BNBC 1993相比有显着变化。在本研究中,地震荷载作用范围为7.42% ~ 59.78%,x方向风力作用范围为19.16% ~ 36.14%,y方向风力作用范围为49.51% ~ 63.78%,地震荷载作用范围为47.96% ~ 51.27%,风荷载作用范围为29.89% ~ 34.45%。本文以图形形式对上述设计参数进行了比较,并给出了相关表格。与BNBC 1993相比,BNBC 2020的要求通常导致具有更高安全裕度的低成本设计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Conformance and Performance Evaluation of Land Use Plan of Yirba Town Performance of Simplified Damage-Based Concrete Models in Seismic Applications Pavement Service Life Prediction with PLAXIS 3D in Bangladesh Surface-Modified Nanoclays for Enhancing Resistance to Moisture Damage in Hot Mix Asphalt Structural Performance Evaluation of Diversion Weir Structure: Case Study of Basaka Small Scale Irrigation Scheme, Oromia, Ethiopia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1