Fabrication of Pb(II) Selective Polymeric Membrane Electrode Based on 2,2’[Propane-1,3-Diylbis(Oxy)]Dibenzaldehyde as an Ionophore. J Anal Bioanal Tech

Karamjeet Kaur, J. Aulakh
{"title":"Fabrication of Pb(II) Selective Polymeric Membrane Electrode Based on 2,2’[Propane-1,3-Diylbis(Oxy)]Dibenzaldehyde as an Ionophore. J Anal Bioanal Tech","authors":"Karamjeet Kaur, J. Aulakh","doi":"10.4172/2155-9872.1000399","DOIUrl":null,"url":null,"abstract":"2,2'-[propane-1,3-diylbis(oxy)]dibenzaldehyde has been explored as an ionophore and fabricated in a polyvinylchloride (PVC)-based membrane. The electrode shows excellent potentiometric response characteristics and displays a linear log [Pb(II)] versus emf response over a wide concentration range of 1.2 × 10-7 M to 1.0 × 10-1 M with detection limit 3.3 × 10-8 M and having nernstian slope of 29.06 mV/decade. Potential response remains almost unchanged at pH range of 3.0-8.0. The electrode shows fast response time of <10 s and a lifetime of four months. It shows good selectivity for Pb(II) ions over the other cations. The complexation 2,2'-[propane-1,3- diylbis(oxy)]dibenzaldehyde and Pb(II) cation was studied spectrophotometrically in 1:1 DMF:H2 O mixed solvents. Spectra shows the strong interaction between Ionophore and Pb(II) ion. The electrode can also be used as an indicator electrode in potentiometric titration of Pb(II) ions with standard chromate solution and its determination in real samples.","PeriodicalId":14865,"journal":{"name":"Journal of analytical and bioanalytical techniques","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical and bioanalytical techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2155-9872.1000399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

2,2'-[propane-1,3-diylbis(oxy)]dibenzaldehyde has been explored as an ionophore and fabricated in a polyvinylchloride (PVC)-based membrane. The electrode shows excellent potentiometric response characteristics and displays a linear log [Pb(II)] versus emf response over a wide concentration range of 1.2 × 10-7 M to 1.0 × 10-1 M with detection limit 3.3 × 10-8 M and having nernstian slope of 29.06 mV/decade. Potential response remains almost unchanged at pH range of 3.0-8.0. The electrode shows fast response time of <10 s and a lifetime of four months. It shows good selectivity for Pb(II) ions over the other cations. The complexation 2,2'-[propane-1,3- diylbis(oxy)]dibenzaldehyde and Pb(II) cation was studied spectrophotometrically in 1:1 DMF:H2 O mixed solvents. Spectra shows the strong interaction between Ionophore and Pb(II) ion. The electrode can also be used as an indicator electrode in potentiometric titration of Pb(II) ions with standard chromate solution and its determination in real samples.
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
以2,2 '[丙烷-1,3-二基双(氧)]二苯甲醛为离子载体制备Pb(II)选择性聚合物膜电极。J肛门生物肛门技术
研究了2,2'-[丙烷-1,3-二基双(氧)]二苯甲醛作为离子载体,并在聚氯乙烯(PVC)基膜中制备。该电极具有优异的电位响应特性,在1.2 × 10-7 M至1.0 × 10-1 M的浓度范围内,Pb(II)与emf响应呈线性对数关系,检测限为3.3 × 10-8 M,能量斜率为29.06 mV/ 10年。pH值在3.0 ~ 8.0范围内,电位响应基本保持不变。该电极的响应时间<10 s,寿命为4个月。它对Pb(II)离子表现出较好的选择性。用分光光度法研究了2,2′-[丙烷-1,3-二基双(氧)]二苯甲醛与Pb(II)阳离子在1:1 DMF:H2 O混合溶剂中的络合作用。光谱显示,离子载体与Pb(II)离子之间存在较强的相互作用。该电极还可作为指示电极用于标准铬酸盐溶液电位滴定铅(II)离子及实际样品的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Elucidation of unknown pharmaceutical degradation products: Structures and pathways Ionic liquids as stationary phase in GC: An innovation for improving food, environmental and petrochemical analysis Leaching of Some Essential and Non-Essential Heavy Metals from Modern Glazed Ceramic Crockeries Imported into Qatar from China, India and Spain A New Approach of Solving the Nonlinear Equations in Biofiltration of Methane in a Closed Biofilter Determination of Some Trace Heavy Metals (Pb, Cr, Cd, Mn and Zn) Levels in Iron Ores from Mines in Wollega (Ethiopia) Using Atomic Absorption Spectrometric Technique
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1