{"title":"Goal-Directed Haemodynamic Therapy Improves Patient Outcomes in Kidney Transplantation.","authors":"Jez Fabes,&nbsp;Ammar Al Midani,&nbsp;Aman S Sarna,&nbsp;Dina H Hadi,&nbsp;Saqib A Naji,&nbsp;Neal R Banga,&nbsp;Gareth L Jones,&nbsp;Peter D Berry,&nbsp;Marc D Wittenberg","doi":"10.1177/15269248231164165","DOIUrl":null,"url":null,"abstract":"<p><p><b>Introduction:</b> Kidney transplant graft function depends on optimised haemodynamics. However, high fluid volumes risk hypervolaemic complications. The Edwards Lifesciences ClearSight™ device permits fluid titration through markers of preload and beat-to-beat blood pressure monitoring. We evaluated the implementation of a novel goal-directed haemodynamic therapy protocol to determine whether patient outcomes had improved. <b>Design:</b> A retrospective evaluation of standard care versus goal-directed haemodynamic therapy in adults undergoing kidney transplantation was performed in a single centre between April 2016 and October 2019. Twenty-eight standard-of-care patients received intraoperative fixed-rate infusion and 28 patients received goal-directed haemodynamic therapy. The primary outcome was volume of fluid administered intraoperatively. Secondary outcomes included blood product and vasoactive drug exposure, graft and recipient outcomes. <b>Results:</b> Intraoperative fluid administered was significantly reduced in the goal-directed haemodynamic therapy cohort (4325 vs 2751 ml, <i>P</i> < .001). Exposure to vasopressor (67.9% vs 42.9%, <i>P</i> = .060) and blood products (17.9% vs 3.6%, <i>P</i> = .101) was unchanged. Immediate graft function (82.1% vs 75.0%, <i>P</i> = .515), dialysis requirement (14.3% vs 21.4%, <i>P</i> = .729) and creatinine changes post-operatively were unchanged. In the goal-directed haemodynamic therapy cohort, 1 patient had pulmonary oedema (3.6%) versus 21.4% in the standard cohort. Patients in the goal-directed haemodynamic therapy group were more likely to mobilise within 48 hours of surgery (number needed to treat = 3.5, <i>P</i> = .012). <b>Conclusions:</b> Protocolised goal-directed haemodynamic therapy in kidney transplantation was safe and may improve patient, graft, and surgical outcomes. Clinical trials assessing goal-directed approaches are needed.</p>","PeriodicalId":20671,"journal":{"name":"Progress in Transplantation","volume":"33 2","pages":"150-155"},"PeriodicalIF":0.6000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15269248231164165","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: Kidney transplant graft function depends on optimised haemodynamics. However, high fluid volumes risk hypervolaemic complications. The Edwards Lifesciences ClearSight™ device permits fluid titration through markers of preload and beat-to-beat blood pressure monitoring. We evaluated the implementation of a novel goal-directed haemodynamic therapy protocol to determine whether patient outcomes had improved. Design: A retrospective evaluation of standard care versus goal-directed haemodynamic therapy in adults undergoing kidney transplantation was performed in a single centre between April 2016 and October 2019. Twenty-eight standard-of-care patients received intraoperative fixed-rate infusion and 28 patients received goal-directed haemodynamic therapy. The primary outcome was volume of fluid administered intraoperatively. Secondary outcomes included blood product and vasoactive drug exposure, graft and recipient outcomes. Results: Intraoperative fluid administered was significantly reduced in the goal-directed haemodynamic therapy cohort (4325 vs 2751 ml, P < .001). Exposure to vasopressor (67.9% vs 42.9%, P = .060) and blood products (17.9% vs 3.6%, P = .101) was unchanged. Immediate graft function (82.1% vs 75.0%, P = .515), dialysis requirement (14.3% vs 21.4%, P = .729) and creatinine changes post-operatively were unchanged. In the goal-directed haemodynamic therapy cohort, 1 patient had pulmonary oedema (3.6%) versus 21.4% in the standard cohort. Patients in the goal-directed haemodynamic therapy group were more likely to mobilise within 48 hours of surgery (number needed to treat = 3.5, P = .012). Conclusions: Protocolised goal-directed haemodynamic therapy in kidney transplantation was safe and may improve patient, graft, and surgical outcomes. Clinical trials assessing goal-directed approaches are needed.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
目标导向血流动力学治疗改善肾移植患者预后。
导言:肾移植的移植物功能取决于优化的血流动力学。然而,高液体容量有高容血性并发症的风险。爱德华兹生命科学ClearSight™设备允许通过预负荷和搏动血压监测标记进行液体滴定。我们评估了一种新的目标导向血流动力学治疗方案的实施情况,以确定患者的预后是否得到改善。设计:2016年4月至2019年10月,在单一中心对接受肾移植的成人进行标准治疗与目标导向血流动力学治疗的回顾性评估。28例标准护理患者接受术中固定速率输液,28例患者接受目标定向血流动力学治疗。主要结果是术中给液量。次要结局包括血液制品和血管活性药物暴露、移植物和受体结局。结果:在目标导向血流动力学治疗队列中,术中给液量显著减少(4325 ml vs 2751 ml, P = 0.060),血液制品(17.9% vs 3.6%, P = 0.101)不变。即刻移植物功能(82.1% vs 75.0%, P = 0.515)、透析需求(14.3% vs 21.4%, P = 0.729)和术后肌酐变化不变。在目标导向血流动力学治疗队列中,1例患者出现肺水肿(3.6%),而标准队列中为21.4%。目标导向血流动力学治疗组患者更有可能在手术后48小时内活动(需要治疗的人数= 3.5,P = 0.012)。结论:协议规定的目标导向血流动力学治疗在肾移植中是安全的,并且可以改善患者、移植物和手术结果。评估目标导向方法的临床试验是必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
Progress in Transplantation
Progress in Transplantation SURGERY-TRANSPLANTATION
CiteScore
1.50
自引率
12.50%
发文量
44
审稿时长
6-12 weeks
期刊介绍: Progress in Transplantation (PIT) is the official journal of NATCO, The Organization for Transplant Professionals. Journal Partners include: Australasian Transplant Coordinators Association and Society for Transplant Social Workers. PIT reflects the multi-disciplinary team approach to procurement and clinical aspects of organ and tissue transplantation by providing a professional forum for exchange of the continually changing body of knowledge in transplantation.
期刊最新文献
A Systematic Review of Anxiety Measurement Scales in Pediatric Organ Transplantation Patients. Immediate Postintervention Outcomes from a Randomized Trial that Sought to Enhance Access to Live Donor Kidney Transplant for Black and African Americans. Empowering the Voice of Patients, Families, and Caregivers Through Participation in Organ Donation and Transplantation Conferences. A Journey From Patient and Physician to Entrepreneur and Advocate in Transplantation. Organ Donation Changed My Life.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1