{"title":"便携式医疗器械用双电极2.88nJ/转换生物电位采集系统","authors":"Long Yan, Namjun Cho, J. Yoo, Binhee Kim, H. Yoo","doi":"10.1109/ASSCC.2008.4708794","DOIUrl":null,"url":null,"abstract":"A 2.88 nJ/Conversion low energy biopotential acquisition system is designed for portable healthcare device. Two dry copper contact electrodes with 1.2-cm diameter are used to easily interface between skin and healthcare device. Chopping technique is adopted at readout front end to obtain thermal noise floor of 1.3 uVrms over 0.5~200 Hz and CMRR over 100 dB to mitigate common-mode body potential induced from AC power line. A 4-stage gain control and band selection blocks are integrated to digitally calibrate for different types of biomedical signal and an 8-bit synchronous successive approximation register (SAR) A/D is used to digitize sensed biopotentials. A test chip is implemented in 0.18 um, 1.8 V supply CMOS technology and successively verified by readout ECG signal with two electrodes contact at chest of body with separating 6 cm.","PeriodicalId":143173,"journal":{"name":"2008 IEEE Asian Solid-State Circuits Conference","volume":"357 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2008-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"19","resultStr":"{\"title\":\"A two-electrode 2.88nJ/conversion biopotential acquisition system for portable healthcare device\",\"authors\":\"Long Yan, Namjun Cho, J. Yoo, Binhee Kim, H. Yoo\",\"doi\":\"10.1109/ASSCC.2008.4708794\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 2.88 nJ/Conversion low energy biopotential acquisition system is designed for portable healthcare device. Two dry copper contact electrodes with 1.2-cm diameter are used to easily interface between skin and healthcare device. Chopping technique is adopted at readout front end to obtain thermal noise floor of 1.3 uVrms over 0.5~200 Hz and CMRR over 100 dB to mitigate common-mode body potential induced from AC power line. A 4-stage gain control and band selection blocks are integrated to digitally calibrate for different types of biomedical signal and an 8-bit synchronous successive approximation register (SAR) A/D is used to digitize sensed biopotentials. A test chip is implemented in 0.18 um, 1.8 V supply CMOS technology and successively verified by readout ECG signal with two electrodes contact at chest of body with separating 6 cm.\",\"PeriodicalId\":143173,\"journal\":{\"name\":\"2008 IEEE Asian Solid-State Circuits Conference\",\"volume\":\"357 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 IEEE Asian Solid-State Circuits Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ASSCC.2008.4708794\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 IEEE Asian Solid-State Circuits Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ASSCC.2008.4708794","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A two-electrode 2.88nJ/conversion biopotential acquisition system for portable healthcare device
A 2.88 nJ/Conversion low energy biopotential acquisition system is designed for portable healthcare device. Two dry copper contact electrodes with 1.2-cm diameter are used to easily interface between skin and healthcare device. Chopping technique is adopted at readout front end to obtain thermal noise floor of 1.3 uVrms over 0.5~200 Hz and CMRR over 100 dB to mitigate common-mode body potential induced from AC power line. A 4-stage gain control and band selection blocks are integrated to digitally calibrate for different types of biomedical signal and an 8-bit synchronous successive approximation register (SAR) A/D is used to digitize sensed biopotentials. A test chip is implemented in 0.18 um, 1.8 V supply CMOS technology and successively verified by readout ECG signal with two electrodes contact at chest of body with separating 6 cm.