{"title":"25kva三相PWM交流线路调节器的设计与实现","authors":"D. Vincenti, H. Jin, P. Ziogas","doi":"10.1109/ISIE.1993.268760","DOIUrl":null,"url":null,"abstract":"An improved version of transistor-based AC line conditioners is proposed. As compared to previously reported structures, it uses fewer standard transistor modules. This, in combination with less stringent gating requirements, improves the overall operating reliability of the system. In addition, it retains the same advantages such as sinusoidal input/output waveforms, fast dynamic response, and small input/output filters. The operating principle of the proposed structure is discussed and the voltage feedback loop design is analyzed. Results from a 25 kVA experimental set-up are provided for verification.<<ETX>>","PeriodicalId":267349,"journal":{"name":"ISIE '93 - Budapest: IEEE International Symposium on Industrial Electronics Conference Proceedings","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1993-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"31","resultStr":"{\"title\":\"Design and implementation of a 25 kVA three-phase PWM AC line conditioner\",\"authors\":\"D. Vincenti, H. Jin, P. Ziogas\",\"doi\":\"10.1109/ISIE.1993.268760\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"An improved version of transistor-based AC line conditioners is proposed. As compared to previously reported structures, it uses fewer standard transistor modules. This, in combination with less stringent gating requirements, improves the overall operating reliability of the system. In addition, it retains the same advantages such as sinusoidal input/output waveforms, fast dynamic response, and small input/output filters. The operating principle of the proposed structure is discussed and the voltage feedback loop design is analyzed. Results from a 25 kVA experimental set-up are provided for verification.<<ETX>>\",\"PeriodicalId\":267349,\"journal\":{\"name\":\"ISIE '93 - Budapest: IEEE International Symposium on Industrial Electronics Conference Proceedings\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"31\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISIE '93 - Budapest: IEEE International Symposium on Industrial Electronics Conference Proceedings\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISIE.1993.268760\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISIE '93 - Budapest: IEEE International Symposium on Industrial Electronics Conference Proceedings","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISIE.1993.268760","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Design and implementation of a 25 kVA three-phase PWM AC line conditioner
An improved version of transistor-based AC line conditioners is proposed. As compared to previously reported structures, it uses fewer standard transistor modules. This, in combination with less stringent gating requirements, improves the overall operating reliability of the system. In addition, it retains the same advantages such as sinusoidal input/output waveforms, fast dynamic response, and small input/output filters. The operating principle of the proposed structure is discussed and the voltage feedback loop design is analyzed. Results from a 25 kVA experimental set-up are provided for verification.<>