相量测量单元的同步及其对状态估计器的误差传播

J. Bazerque, U. Ribeiro, Jorge Costa
{"title":"相量测量单元的同步及其对状态估计器的误差传播","authors":"J. Bazerque, U. Ribeiro, Jorge Costa","doi":"10.1109/ISGT-LA.2015.7381207","DOIUrl":null,"url":null,"abstract":"The recent breakthrough on power grid technologies was promoted by the emergence of phasor measurement units (PMUs), as they provide direct and high-rate data for analyzing and controlling the network. Time becomes critical however, since offsets in the internal clocks of PMUs render their data unreliable. In this context, the present work describes grid-wide implementation of a Precision Time Protocol system to deliver an accurate time reference to PMUs at different power stations. Residual time offsets are modeled as PMU noise, propagating to linear state estimators, and their non-linear counterparts that result from combining PMU and power flow data.","PeriodicalId":345318,"journal":{"name":"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)","volume":"56 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Synchronization of phasor measurement units and its error propagation to state estimators\",\"authors\":\"J. Bazerque, U. Ribeiro, Jorge Costa\",\"doi\":\"10.1109/ISGT-LA.2015.7381207\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The recent breakthrough on power grid technologies was promoted by the emergence of phasor measurement units (PMUs), as they provide direct and high-rate data for analyzing and controlling the network. Time becomes critical however, since offsets in the internal clocks of PMUs render their data unreliable. In this context, the present work describes grid-wide implementation of a Precision Time Protocol system to deliver an accurate time reference to PMUs at different power stations. Residual time offsets are modeled as PMU noise, propagating to linear state estimators, and their non-linear counterparts that result from combining PMU and power flow data.\",\"PeriodicalId\":345318,\"journal\":{\"name\":\"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)\",\"volume\":\"56 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-LA.2015.7381207\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-LA.2015.7381207","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

最近电网技术的突破是由相量测量单元(pmu)的出现推动的,因为它们为分析和控制网络提供了直接和高速率的数据。然而,时间变得至关重要,因为pmu内部时钟的偏移使其数据不可靠。在这种情况下,本工作描述了精确时间协议系统在电网范围内的实现,该系统为不同发电站的pmu提供准确的时间参考。剩余时间偏移被建模为PMU噪声,传播到线性状态估计器,以及由PMU和潮流数据组合而成的非线性状态估计器。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Synchronization of phasor measurement units and its error propagation to state estimators
The recent breakthrough on power grid technologies was promoted by the emergence of phasor measurement units (PMUs), as they provide direct and high-rate data for analyzing and controlling the network. Time becomes critical however, since offsets in the internal clocks of PMUs render their data unreliable. In this context, the present work describes grid-wide implementation of a Precision Time Protocol system to deliver an accurate time reference to PMUs at different power stations. Residual time offsets are modeled as PMU noise, propagating to linear state estimators, and their non-linear counterparts that result from combining PMU and power flow data.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Design of model-based controllers applied to a solid-state low voltage dc breaker An agent-based negotiation approach for balancing multiple coupled control domains A model-free voltage stability security assessment method using artificial intelligence Description of the simulator developed for the new RAS to be installed in the power system of Uruguay Multi-objective optimization model for distribution systems restoration
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1