Earl Fairall, Cody Rheberhegen, Elizabeth Rowan, J. Lo, B. Bilgin, A. Emadi
{"title":"在液冷开关磁阻电机中最大化热效率和最小化寄生损耗","authors":"Earl Fairall, Cody Rheberhegen, Elizabeth Rowan, J. Lo, B. Bilgin, A. Emadi","doi":"10.1109/ITEC.2016.7520308","DOIUrl":null,"url":null,"abstract":"The following paper describes three components comprising a thermal management system for a 22,000RPM 150kW switched reluctance machine. The three systems cooling the stator include: jacket cooling, slot cooling and an end-turn cooling systems. The cooling jacket is a dual-flute helical heat exchanger with counterflow coolant. Slot and end-turn cooling systems utilize polymer materials to transport coolant near machine windings with minimal eddy current generation and modest thermal conductivity values. Encapsulate doping was investigated as a method of increasing heat transfer to the cooling systems. Manufacturing and design philosophy is discussed for each system.","PeriodicalId":280676,"journal":{"name":"2016 IEEE Transportation Electrification Conference and Expo (ITEC)","volume":"49 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Maximizing thermal effectiveness and minimizing parasitic loss in a liquid cooled switched reluctance machine\",\"authors\":\"Earl Fairall, Cody Rheberhegen, Elizabeth Rowan, J. Lo, B. Bilgin, A. Emadi\",\"doi\":\"10.1109/ITEC.2016.7520308\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The following paper describes three components comprising a thermal management system for a 22,000RPM 150kW switched reluctance machine. The three systems cooling the stator include: jacket cooling, slot cooling and an end-turn cooling systems. The cooling jacket is a dual-flute helical heat exchanger with counterflow coolant. Slot and end-turn cooling systems utilize polymer materials to transport coolant near machine windings with minimal eddy current generation and modest thermal conductivity values. Encapsulate doping was investigated as a method of increasing heat transfer to the cooling systems. Manufacturing and design philosophy is discussed for each system.\",\"PeriodicalId\":280676,\"journal\":{\"name\":\"2016 IEEE Transportation Electrification Conference and Expo (ITEC)\",\"volume\":\"49 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Transportation Electrification Conference and Expo (ITEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ITEC.2016.7520308\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Transportation Electrification Conference and Expo (ITEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ITEC.2016.7520308","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Maximizing thermal effectiveness and minimizing parasitic loss in a liquid cooled switched reluctance machine
The following paper describes three components comprising a thermal management system for a 22,000RPM 150kW switched reluctance machine. The three systems cooling the stator include: jacket cooling, slot cooling and an end-turn cooling systems. The cooling jacket is a dual-flute helical heat exchanger with counterflow coolant. Slot and end-turn cooling systems utilize polymer materials to transport coolant near machine windings with minimal eddy current generation and modest thermal conductivity values. Encapsulate doping was investigated as a method of increasing heat transfer to the cooling systems. Manufacturing and design philosophy is discussed for each system.