{"title":"一种增加热过载能力的t型NPC逆变器容错拓扑","authors":"Jiangbiao He, N. Weise, Lixiang Wei, N. Demerdash","doi":"10.1109/APEC.2016.7468002","DOIUrl":null,"url":null,"abstract":"Reliability of multilevel power converters has received increased attention over the past few years, due to the relatively high component failure probability caused by the large number of switching devices utilized in the converter topologies. Thus, the fault-tolerant operation of multilevel converters plays an essential role in safety-critical industrial applications. This paper introduces an improved fault-tolerant inverter topology based on the conventional three-level T-Type neutral-point-clamped (NPC) inverter. Unlike other existing three-phase four-leg fault-tolerant inverter topologies, the fault-tolerant T-Type inverter topology proposed here can significantly enhance the overall thermal overload capability of the inverter, in addition to providing desired fault-tolerant capability. The operating principle of this proposed fault-tolerant T-Type inverter is detailed in this paper, and simulation results are presented to verify the advantages of this improved inverter topology.","PeriodicalId":143091,"journal":{"name":"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)","volume":"1 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2016-03-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"14","resultStr":"{\"title\":\"A fault-tolerant topology of T-Type NPC inverter with increased thermal overload capability\",\"authors\":\"Jiangbiao He, N. Weise, Lixiang Wei, N. Demerdash\",\"doi\":\"10.1109/APEC.2016.7468002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Reliability of multilevel power converters has received increased attention over the past few years, due to the relatively high component failure probability caused by the large number of switching devices utilized in the converter topologies. Thus, the fault-tolerant operation of multilevel converters plays an essential role in safety-critical industrial applications. This paper introduces an improved fault-tolerant inverter topology based on the conventional three-level T-Type neutral-point-clamped (NPC) inverter. Unlike other existing three-phase four-leg fault-tolerant inverter topologies, the fault-tolerant T-Type inverter topology proposed here can significantly enhance the overall thermal overload capability of the inverter, in addition to providing desired fault-tolerant capability. The operating principle of this proposed fault-tolerant T-Type inverter is detailed in this paper, and simulation results are presented to verify the advantages of this improved inverter topology.\",\"PeriodicalId\":143091,\"journal\":{\"name\":\"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"volume\":\"1 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-03-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/APEC.2016.7468002\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Applied Power Electronics Conference and Exposition (APEC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/APEC.2016.7468002","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A fault-tolerant topology of T-Type NPC inverter with increased thermal overload capability
Reliability of multilevel power converters has received increased attention over the past few years, due to the relatively high component failure probability caused by the large number of switching devices utilized in the converter topologies. Thus, the fault-tolerant operation of multilevel converters plays an essential role in safety-critical industrial applications. This paper introduces an improved fault-tolerant inverter topology based on the conventional three-level T-Type neutral-point-clamped (NPC) inverter. Unlike other existing three-phase four-leg fault-tolerant inverter topologies, the fault-tolerant T-Type inverter topology proposed here can significantly enhance the overall thermal overload capability of the inverter, in addition to providing desired fault-tolerant capability. The operating principle of this proposed fault-tolerant T-Type inverter is detailed in this paper, and simulation results are presented to verify the advantages of this improved inverter topology.