E. Inga-Ortega, A. Peralta-Sevilla, R. Hincapié, F. Amaya, I. Tafur Monroy
{"title":"智能电网先进计量基础设施上wi - fi网络的优化尺寸","authors":"E. Inga-Ortega, A. Peralta-Sevilla, R. Hincapié, F. Amaya, I. Tafur Monroy","doi":"10.1109/ISGT-LA.2015.7381125","DOIUrl":null,"url":null,"abstract":"In this paper, we propose a hybrid wireless mesh network infrastructure which connects the smart meters of each consumer with the data aggregation points (DAP). We suppose a set of smart meters that need to send information, and receive information from a central office on electrical enterprises, employing the meter data management system (MDMS), and so forming the advanced metering infrastructure (AMI) stage of smart grids. We consider a multi-hop system, where information is routed through several nodes which act as DAP. Wireless mesh networks are known to extend coverage and increase deployment efficiency, so they could be an alternative for the connection between Home Area Network (HAN) and the Neighborhood Area Network (NAN). However, the NAN data must be send through wider area cabled networks to Metropolitan Area Network (MAN), and based on the WDM-PON architecture. We consider a novel planning model which simultaneously solves both architectures and analyses the overall performance based on average packet delay.","PeriodicalId":345318,"journal":{"name":"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)","volume":"40 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"27","resultStr":"{\"title\":\"Optimal dimensioning of FiWi networks over advanced metering infrastructure for the smart grid\",\"authors\":\"E. Inga-Ortega, A. Peralta-Sevilla, R. Hincapié, F. Amaya, I. Tafur Monroy\",\"doi\":\"10.1109/ISGT-LA.2015.7381125\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, we propose a hybrid wireless mesh network infrastructure which connects the smart meters of each consumer with the data aggregation points (DAP). We suppose a set of smart meters that need to send information, and receive information from a central office on electrical enterprises, employing the meter data management system (MDMS), and so forming the advanced metering infrastructure (AMI) stage of smart grids. We consider a multi-hop system, where information is routed through several nodes which act as DAP. Wireless mesh networks are known to extend coverage and increase deployment efficiency, so they could be an alternative for the connection between Home Area Network (HAN) and the Neighborhood Area Network (NAN). However, the NAN data must be send through wider area cabled networks to Metropolitan Area Network (MAN), and based on the WDM-PON architecture. We consider a novel planning model which simultaneously solves both architectures and analyses the overall performance based on average packet delay.\",\"PeriodicalId\":345318,\"journal\":{\"name\":\"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)\",\"volume\":\"40 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"27\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISGT-LA.2015.7381125\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE PES Innovative Smart Grid Technologies Latin America (ISGT LATAM)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISGT-LA.2015.7381125","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Optimal dimensioning of FiWi networks over advanced metering infrastructure for the smart grid
In this paper, we propose a hybrid wireless mesh network infrastructure which connects the smart meters of each consumer with the data aggregation points (DAP). We suppose a set of smart meters that need to send information, and receive information from a central office on electrical enterprises, employing the meter data management system (MDMS), and so forming the advanced metering infrastructure (AMI) stage of smart grids. We consider a multi-hop system, where information is routed through several nodes which act as DAP. Wireless mesh networks are known to extend coverage and increase deployment efficiency, so they could be an alternative for the connection between Home Area Network (HAN) and the Neighborhood Area Network (NAN). However, the NAN data must be send through wider area cabled networks to Metropolitan Area Network (MAN), and based on the WDM-PON architecture. We consider a novel planning model which simultaneously solves both architectures and analyses the overall performance based on average packet delay.