在胸肌应用中有cpap应用:尽量缓解颅内压力,避免并发症

T. Lesser
{"title":"在胸肌应用中有cpap应用:尽量缓解颅内压力,避免并发症","authors":"T. Lesser","doi":"10.1159/000505220","DOIUrl":null,"url":null,"abstract":"Background: Excessive drop of pleural pressure (Ppl) during therapeutic thoracentesis may be related to adverse events and/or to repeated procedures due to incomplete drainage. Objective: This was a pilot study of the impact of the application of continuous positive airway pressure (CPAP) at +5 cm H2O upon the Ppl profile during thoracentesis. Methods: This was a prospective, controlled study of 49 consecutive adults who underwent thoracentesis. Enrollment was via alternation on a one-to-one basis. Pleural manometry was used to compare serial Ppl in patients using CPAP at +5 cm H2O (CPAP group) with Ppl in patients without CPAP (control group). Results: Mean volumes drained were comparable between CPAP and control groups (1,380 vs. 1,396 mL). Patients in the CPAP group had a significantly greater change in volume per centimeter water column pressure (p = 0.0231, 95% confidence interval 6.41-82.61). No patient in the CPAP group had a Ppl less than -20 cm H2O at termination of the procedure, while 8 (33%) control group patients developed a pressure lower than -20. No patient in either group developed re-expansion pulmonary edema. Conclusion: The application of CPAP at +5 cm H2O mitigates the decreases in Ppl caused by thoracentesis via an increase in pleural compliance. The clinical implications of this finding merit study.","PeriodicalId":306175,"journal":{"name":"Karger Kompass Pneumologie","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CPAP-Applikation bei der Thorakozentese: Pleuralen Druckabfall mindern und Komplikationen verhindern\",\"authors\":\"T. Lesser\",\"doi\":\"10.1159/000505220\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Excessive drop of pleural pressure (Ppl) during therapeutic thoracentesis may be related to adverse events and/or to repeated procedures due to incomplete drainage. Objective: This was a pilot study of the impact of the application of continuous positive airway pressure (CPAP) at +5 cm H2O upon the Ppl profile during thoracentesis. Methods: This was a prospective, controlled study of 49 consecutive adults who underwent thoracentesis. Enrollment was via alternation on a one-to-one basis. Pleural manometry was used to compare serial Ppl in patients using CPAP at +5 cm H2O (CPAP group) with Ppl in patients without CPAP (control group). Results: Mean volumes drained were comparable between CPAP and control groups (1,380 vs. 1,396 mL). Patients in the CPAP group had a significantly greater change in volume per centimeter water column pressure (p = 0.0231, 95% confidence interval 6.41-82.61). No patient in the CPAP group had a Ppl less than -20 cm H2O at termination of the procedure, while 8 (33%) control group patients developed a pressure lower than -20. No patient in either group developed re-expansion pulmonary edema. Conclusion: The application of CPAP at +5 cm H2O mitigates the decreases in Ppl caused by thoracentesis via an increase in pleural compliance. The clinical implications of this finding merit study.\",\"PeriodicalId\":306175,\"journal\":{\"name\":\"Karger Kompass Pneumologie\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Karger Kompass Pneumologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000505220\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Karger Kompass Pneumologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000505220","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:治疗性胸腔穿刺过程中胸膜压(Ppl)的过度下降可能与不良事件和/或由于引流不完全导致的重复手术有关。目的:这是一项在+5 cm H2O下应用持续气道正压通气(CPAP)对胸腔穿刺期间Ppl谱影响的初步研究。方法:这是一项前瞻性对照研究,49名连续接受胸腔穿刺的成年人。注册是在一对一的基础上进行的。采用胸膜测压法比较+5 cm H2O时使用CPAP的患者(CPAP组)与未使用CPAP的患者(对照组)的Ppl序列。结果:CPAP组和对照组的平均排气量相当(1380 mL vs 1396 mL)。CPAP组患者每厘米水柱压力的容积变化更大(p = 0.0231, 95%可信区间为6.41-82.61)。CPAP组无患者在手术结束时Ppl低于-20 cm H2O,而8例(33%)对照组患者血压低于-20。两组患者均未发生再扩张性肺水肿。结论:在+ 5cm H2O下应用CPAP可通过增加胸膜依从性来减轻胸腔穿刺引起的Ppl下降。这一发现的临床意义值得进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
CPAP-Applikation bei der Thorakozentese: Pleuralen Druckabfall mindern und Komplikationen verhindern
Background: Excessive drop of pleural pressure (Ppl) during therapeutic thoracentesis may be related to adverse events and/or to repeated procedures due to incomplete drainage. Objective: This was a pilot study of the impact of the application of continuous positive airway pressure (CPAP) at +5 cm H2O upon the Ppl profile during thoracentesis. Methods: This was a prospective, controlled study of 49 consecutive adults who underwent thoracentesis. Enrollment was via alternation on a one-to-one basis. Pleural manometry was used to compare serial Ppl in patients using CPAP at +5 cm H2O (CPAP group) with Ppl in patients without CPAP (control group). Results: Mean volumes drained were comparable between CPAP and control groups (1,380 vs. 1,396 mL). Patients in the CPAP group had a significantly greater change in volume per centimeter water column pressure (p = 0.0231, 95% confidence interval 6.41-82.61). No patient in the CPAP group had a Ppl less than -20 cm H2O at termination of the procedure, while 8 (33%) control group patients developed a pressure lower than -20. No patient in either group developed re-expansion pulmonary edema. Conclusion: The application of CPAP at +5 cm H2O mitigates the decreases in Ppl caused by thoracentesis via an increase in pleural compliance. The clinical implications of this finding merit study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Zentrale Schlafapnoe bei Patienten mit Herzinsuffizienz: Physiologische Auswirkungen der periodischen Beatmung Kaleidoskop Malignes Mesotheliom: Die diagnostische Aussagekraft einer Computertomographie kritisch hinterfragen Pneumocampus PharmaNews
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1