{"title":"先进的整流器和驱动模拟VU仪表","authors":"M. Pospisilik, M. Adamek","doi":"10.1109/DDECS.2011.5783127","DOIUrl":null,"url":null,"abstract":"This paper deals with a construction and practical testing of a VU meter driver that includes an accurate rectifier and logarithmic driver of a pointer-type gauge. The logarithm is taken from the rectified signal by employing a capacitor discharge voltage curve. The appropriate circuit was built and tested and the results are also discussed in this article.","PeriodicalId":231389,"journal":{"name":"14th IEEE International Symposium on Design and Diagnostics of Electronic Circuits and Systems","volume":"10 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2011-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advanced rectifier and driver for analog VU meter\",\"authors\":\"M. Pospisilik, M. Adamek\",\"doi\":\"10.1109/DDECS.2011.5783127\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper deals with a construction and practical testing of a VU meter driver that includes an accurate rectifier and logarithmic driver of a pointer-type gauge. The logarithm is taken from the rectified signal by employing a capacitor discharge voltage curve. The appropriate circuit was built and tested and the results are also discussed in this article.\",\"PeriodicalId\":231389,\"journal\":{\"name\":\"14th IEEE International Symposium on Design and Diagnostics of Electronic Circuits and Systems\",\"volume\":\"10 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-04-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"14th IEEE International Symposium on Design and Diagnostics of Electronic Circuits and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/DDECS.2011.5783127\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"14th IEEE International Symposium on Design and Diagnostics of Electronic Circuits and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/DDECS.2011.5783127","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
This paper deals with a construction and practical testing of a VU meter driver that includes an accurate rectifier and logarithmic driver of a pointer-type gauge. The logarithm is taken from the rectified signal by employing a capacitor discharge voltage curve. The appropriate circuit was built and tested and the results are also discussed in this article.