{"title":"软x射线低阻硅漂移探测器阵列的研制","authors":"W. Chen, G. de Geronimo, J. Gaskin, S. Li, Z. Li, B. Ramsey, G. Smith","doi":"10.1109/NSSMIC.2012.6551243","DOIUrl":null,"url":null,"abstract":"New silicon drift detector (SDD) arrays are being developed for use as extraterrestrial X-ray spectrometers. For the first time these SDDs have been produced on low resistivity, n-type silicon, with a thinner thickness than normal, effectively ensuring their radiation hardness in anticipation of operation in potentially harsh radiation environments (such as those found around Jupiter). To achieve low-energy X-ray response, a thin entrance window was produced using a double implantation technology. The design, fabrication and performance of these detectors are presented here.","PeriodicalId":187728,"journal":{"name":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","volume":"214 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2012-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Development of low-resistivity silicon drift detector arrays for soft X-rays\",\"authors\":\"W. Chen, G. de Geronimo, J. Gaskin, S. Li, Z. Li, B. Ramsey, G. Smith\",\"doi\":\"10.1109/NSSMIC.2012.6551243\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"New silicon drift detector (SDD) arrays are being developed for use as extraterrestrial X-ray spectrometers. For the first time these SDDs have been produced on low resistivity, n-type silicon, with a thinner thickness than normal, effectively ensuring their radiation hardness in anticipation of operation in potentially harsh radiation environments (such as those found around Jupiter). To achieve low-energy X-ray response, a thin entrance window was produced using a double implantation technology. The design, fabrication and performance of these detectors are presented here.\",\"PeriodicalId\":187728,\"journal\":{\"name\":\"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)\",\"volume\":\"214 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/NSSMIC.2012.6551243\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Nuclear Science Symposium and Medical Imaging Conference Record (NSS/MIC)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/NSSMIC.2012.6551243","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of low-resistivity silicon drift detector arrays for soft X-rays
New silicon drift detector (SDD) arrays are being developed for use as extraterrestrial X-ray spectrometers. For the first time these SDDs have been produced on low resistivity, n-type silicon, with a thinner thickness than normal, effectively ensuring their radiation hardness in anticipation of operation in potentially harsh radiation environments (such as those found around Jupiter). To achieve low-energy X-ray response, a thin entrance window was produced using a double implantation technology. The design, fabrication and performance of these detectors are presented here.