t -扫描系统对咬合接触显示及准确度的研究

M Yamamura, A Takahashi, H Aoki, N Takeuchi, Y Endo, K Tamaki, Y Sano, S Fujiwara, T Fujita, S Kusunoki
{"title":"t -扫描系统对咬合接触显示及准确度的研究","authors":"M Yamamura,&nbsp;A Takahashi,&nbsp;H Aoki,&nbsp;N Takeuchi,&nbsp;Y Endo,&nbsp;K Tamaki,&nbsp;Y Sano,&nbsp;S Fujiwara,&nbsp;T Fujita,&nbsp;S Kusunoki","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The various methods were introduced in the daily prosthodontic field evaluating occlusal contacts for diagnosis and analysis. Maness in 1987 developed the T-Scan system, which is considered as a new computerized device capable to interpret occlusal contacts information quantitatively. The system is composed of a sensor, sensor frame, handle, cable and system unit. Record and analysis mode made possible the occlusal contacts in three ways, such as the balance plot, the time display and comparison screen. However, accuracy and reproducibility of occlusal marking through this system is still uncertain. Therefore, this preliminary study was conducted on four specific points loaded on a sensor by application of the weight of 0.1 kg through 10 kg. The following results were obtained 1. There exists certain non-sensible areas caused by its constructional feature. 2. The most sensible area can be measured from 0.1 Kg to 2.1 Kg, and therefore, this device is more suitable for recording within lower loadings. 3. Although the system has a certain disadvantage of reproducibility, this contributes to attain diagnosis and treatment of occlusal contacts for a quantitative evaluation.</p>","PeriodicalId":77564,"journal":{"name":"Kanagawa shigaku. The Journal of the Kanagawa Odontological Society","volume":"25 2","pages":"236-41"},"PeriodicalIF":0.0000,"publicationDate":"1990-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[A study on display and accuracy of occlusal contacts by means of T-Scan System].\",\"authors\":\"M Yamamura,&nbsp;A Takahashi,&nbsp;H Aoki,&nbsp;N Takeuchi,&nbsp;Y Endo,&nbsp;K Tamaki,&nbsp;Y Sano,&nbsp;S Fujiwara,&nbsp;T Fujita,&nbsp;S Kusunoki\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The various methods were introduced in the daily prosthodontic field evaluating occlusal contacts for diagnosis and analysis. Maness in 1987 developed the T-Scan system, which is considered as a new computerized device capable to interpret occlusal contacts information quantitatively. The system is composed of a sensor, sensor frame, handle, cable and system unit. Record and analysis mode made possible the occlusal contacts in three ways, such as the balance plot, the time display and comparison screen. However, accuracy and reproducibility of occlusal marking through this system is still uncertain. Therefore, this preliminary study was conducted on four specific points loaded on a sensor by application of the weight of 0.1 kg through 10 kg. The following results were obtained 1. There exists certain non-sensible areas caused by its constructional feature. 2. The most sensible area can be measured from 0.1 Kg to 2.1 Kg, and therefore, this device is more suitable for recording within lower loadings. 3. Although the system has a certain disadvantage of reproducibility, this contributes to attain diagnosis and treatment of occlusal contacts for a quantitative evaluation.</p>\",\"PeriodicalId\":77564,\"journal\":{\"name\":\"Kanagawa shigaku. The Journal of the Kanagawa Odontological Society\",\"volume\":\"25 2\",\"pages\":\"236-41\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kanagawa shigaku. The Journal of the Kanagawa Odontological Society\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kanagawa shigaku. The Journal of the Kanagawa Odontological Society","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了日常口腔修复领域中各种评价咬合接触的方法,用于诊断和分析。Maness于1987年开发了T-Scan系统,这被认为是一种新的计算机化设备,能够定量地解释咬合接触信息。该系统由传感器、传感器架、手柄、电缆和系统单元组成。记录分析模式使咬合接触通过平衡图、时间显示和对比屏三种方式实现。然而,通过该系统进行咬合标记的准确性和可重复性仍然不确定。因此,本初步研究是通过施加0.1 kg到10 kg的重量,对传感器上的四个特定点进行加载。得到以下结果:1。由于其构造特点,存在一定的不敏感区域。2. 最敏感的区域可以从0.1 Kg到2.1 Kg测量,因此,该设备更适合在较低的负载下进行记录。3.虽然该系统有一定的可重复性的缺点,这有助于获得咬合接触的诊断和治疗的定量评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
[A study on display and accuracy of occlusal contacts by means of T-Scan System].

The various methods were introduced in the daily prosthodontic field evaluating occlusal contacts for diagnosis and analysis. Maness in 1987 developed the T-Scan system, which is considered as a new computerized device capable to interpret occlusal contacts information quantitatively. The system is composed of a sensor, sensor frame, handle, cable and system unit. Record and analysis mode made possible the occlusal contacts in three ways, such as the balance plot, the time display and comparison screen. However, accuracy and reproducibility of occlusal marking through this system is still uncertain. Therefore, this preliminary study was conducted on four specific points loaded on a sensor by application of the weight of 0.1 kg through 10 kg. The following results were obtained 1. There exists certain non-sensible areas caused by its constructional feature. 2. The most sensible area can be measured from 0.1 Kg to 2.1 Kg, and therefore, this device is more suitable for recording within lower loadings. 3. Although the system has a certain disadvantage of reproducibility, this contributes to attain diagnosis and treatment of occlusal contacts for a quantitative evaluation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
[Studies on immunobiological activities of periodontopathic bacteria. Comparison of the activities of soluble components from Bacteroides gingivalis and Actinomyces viscosus]. [Age estimation by amino acid racemization in teeth. A comparison of data for aspartic acid, glutamic acid and alanine]. [Three-dimensional study of the microvascular network in the excretory end portion and the excretory ducts system of dog parotid gland]. [Phosphotyrosine phosphatase activity of human periodontal ligament fibroblasts (HPLF)]. [Basic investigation of saliva SIgA].
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1