并联补偿器提供的实际功率调制对阻尼功率波动的影响

D. A. Pastos, G. Giannakopoulos, N. Vovos
{"title":"并联补偿器提供的实际功率调制对阻尼功率波动的影响","authors":"D. A. Pastos, G. Giannakopoulos, N. Vovos","doi":"10.1109/ICECS.1996.584526","DOIUrl":null,"url":null,"abstract":"In this paper a comparison is made between the conventional shunt compensator (Static Var Compensator, SVC) providing only reactive power modulation and the GTO-based advanced compensator (Static Condenser, STATCON) providing both active and reactive power modulation, regarding their effectiveness in damping power oscillations. Based on small purturbation analysis, the damping efficiency in terms of the real power flow change caused by a change of the compensating reactive or real power is calculated and compared. Also, the dependence of the damping on the compensator and load location is investigated.","PeriodicalId":402369,"journal":{"name":"Proceedings of Third International Conference on Electronics, Circuits, and Systems","volume":"201 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1996-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Influence of the real power modulation provided by a shunt compensator on damping power swings\",\"authors\":\"D. A. Pastos, G. Giannakopoulos, N. Vovos\",\"doi\":\"10.1109/ICECS.1996.584526\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper a comparison is made between the conventional shunt compensator (Static Var Compensator, SVC) providing only reactive power modulation and the GTO-based advanced compensator (Static Condenser, STATCON) providing both active and reactive power modulation, regarding their effectiveness in damping power oscillations. Based on small purturbation analysis, the damping efficiency in terms of the real power flow change caused by a change of the compensating reactive or real power is calculated and compared. Also, the dependence of the damping on the compensator and load location is investigated.\",\"PeriodicalId\":402369,\"journal\":{\"name\":\"Proceedings of Third International Conference on Electronics, Circuits, and Systems\",\"volume\":\"201 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Third International Conference on Electronics, Circuits, and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICECS.1996.584526\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Third International Conference on Electronics, Circuits, and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICECS.1996.584526","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文比较了仅提供无功调制的传统并联补偿器(静态无功补偿器,SVC)和同时提供有功和无功调制的基于gto的先进补偿器(静态电容,STATCON)在抑制功率振荡方面的效果。在小扰动分析的基础上,计算并比较了补偿无功和实际功率变化对实际潮流变化的阻尼效率。此外,还研究了阻尼与补偿器和负载位置的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Influence of the real power modulation provided by a shunt compensator on damping power swings
In this paper a comparison is made between the conventional shunt compensator (Static Var Compensator, SVC) providing only reactive power modulation and the GTO-based advanced compensator (Static Condenser, STATCON) providing both active and reactive power modulation, regarding their effectiveness in damping power oscillations. Based on small purturbation analysis, the damping efficiency in terms of the real power flow change caused by a change of the compensating reactive or real power is calculated and compared. Also, the dependence of the damping on the compensator and load location is investigated.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Low-power digital PLL with one cycle frequency lock-in time and large frequency-multiplication factor for advanced power management Application of direct iteration in harmonic balance analysis of LC oscillators A Hilbert fractal codec for region oriented compression of color images Wideband CMOS analog cells for video and wireless communications Programmable sampled data filter with low sensitivity implementation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1