Kristian Stærk, Louise Langhorn, Bo Halle, Thomas Emil Andersen
{"title":"雌猪膀胱导尿术:膀胱内容物和大肠杆菌尿路感染对手术结果的影响。","authors":"Kristian Stærk, Louise Langhorn, Bo Halle, Thomas Emil Andersen","doi":"10.1177/00236772231169344","DOIUrl":null,"url":null,"abstract":"<p><p>Catheterisation of the urinary bladder is needed in many types of human disease models in pigs. Based on our extensive experience with the pig as an infection model, we here demonstrate an approach of catheterising domestic pigs (40 attempts) and Göttingen minipigs (10 attempts) using a blinded method, that is, without speculums or videoscopes to visualise the urethral opening. The procedure was tested on control animals and pigs with experimental <i>Escherichia coli</i> urinary tract infection (UTI) to assess the potential influence of this condition on procedural outcome. Lastly, we performed cystoscopy in three animals to visualise the route to the urethra and to localise potential anatomical obstacles. All domestic pigs were catheterised successfully in an average of 2 minutes and 23 seconds, and this was not influenced by UTI (<i>p</i> = 0.06) or bladder urine content at the time of catheterisation (<i>p</i> = 0.32). All Göttingen minipigs were successfully catheterised in an average of 4 minutes and 27 seconds. We conclude that blinded catheterisation is a fast and reliable approach that can be performed in pigs with or without UTI with minimal risk of trauma or contamination.</p>","PeriodicalId":18013,"journal":{"name":"Laboratory Animals","volume":" ","pages":"252-260"},"PeriodicalIF":1.3000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Urinary bladder catheterisation of female pigs: Influence of bladder content and <i>Escherichia coli</i> urinary tract infection on procedural outcome.\",\"authors\":\"Kristian Stærk, Louise Langhorn, Bo Halle, Thomas Emil Andersen\",\"doi\":\"10.1177/00236772231169344\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Catheterisation of the urinary bladder is needed in many types of human disease models in pigs. Based on our extensive experience with the pig as an infection model, we here demonstrate an approach of catheterising domestic pigs (40 attempts) and Göttingen minipigs (10 attempts) using a blinded method, that is, without speculums or videoscopes to visualise the urethral opening. The procedure was tested on control animals and pigs with experimental <i>Escherichia coli</i> urinary tract infection (UTI) to assess the potential influence of this condition on procedural outcome. Lastly, we performed cystoscopy in three animals to visualise the route to the urethra and to localise potential anatomical obstacles. All domestic pigs were catheterised successfully in an average of 2 minutes and 23 seconds, and this was not influenced by UTI (<i>p</i> = 0.06) or bladder urine content at the time of catheterisation (<i>p</i> = 0.32). All Göttingen minipigs were successfully catheterised in an average of 4 minutes and 27 seconds. We conclude that blinded catheterisation is a fast and reliable approach that can be performed in pigs with or without UTI with minimal risk of trauma or contamination.</p>\",\"PeriodicalId\":18013,\"journal\":{\"name\":\"Laboratory Animals\",\"volume\":\" \",\"pages\":\"252-260\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Animals\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00236772231169344\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Animals","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00236772231169344","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/9 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
Urinary bladder catheterisation of female pigs: Influence of bladder content and Escherichia coli urinary tract infection on procedural outcome.
Catheterisation of the urinary bladder is needed in many types of human disease models in pigs. Based on our extensive experience with the pig as an infection model, we here demonstrate an approach of catheterising domestic pigs (40 attempts) and Göttingen minipigs (10 attempts) using a blinded method, that is, without speculums or videoscopes to visualise the urethral opening. The procedure was tested on control animals and pigs with experimental Escherichia coli urinary tract infection (UTI) to assess the potential influence of this condition on procedural outcome. Lastly, we performed cystoscopy in three animals to visualise the route to the urethra and to localise potential anatomical obstacles. All domestic pigs were catheterised successfully in an average of 2 minutes and 23 seconds, and this was not influenced by UTI (p = 0.06) or bladder urine content at the time of catheterisation (p = 0.32). All Göttingen minipigs were successfully catheterised in an average of 4 minutes and 27 seconds. We conclude that blinded catheterisation is a fast and reliable approach that can be performed in pigs with or without UTI with minimal risk of trauma or contamination.
期刊介绍:
The international journal of laboratory animal science and welfare, Laboratory Animals publishes peer-reviewed original papers and reviews on all aspects of the use of animals in biomedical research. The journal promotes improvements in the welfare or well-being of the animals used, it particularly focuses on research that reduces the number of animals used or which replaces animal models with in vitro alternatives.