Pawankumar Rai, Srishti Mehrotra, Vaibhavi Lahane, Akhilesh K. Yadav, Sandeep K. Sharma
{"title":"开发基于正压的高效固相萃取仪器","authors":"Pawankumar Rai, Srishti Mehrotra, Vaibhavi Lahane, Akhilesh K. Yadav, Sandeep K. Sharma","doi":"10.1007/s13197-024-06010-3","DOIUrl":null,"url":null,"abstract":"<div><p>Solid phase extraction technique is a widely used sample preparation technique for the extraction of components from complex food matrices. However, there are several parameters in SPE that leads to low recovery, and reproducibility, insufficiently clean extracts and evaporation of volatile compounds. These drawbacks can be addressed through the use of innovative techniques and instrumentation that offers improved efficiency and accuracy for isolation of active constituents from food and beverage samples. Here a solid phase extraction methodology and extraction assembly has been developed for extracting compounds from orange fruit juice, followed by analysis using a LC-HRMS system. The methodology and assembly eliminate the evaporation step, thus facilitating the analysis of wide range of volatile and non-volatile compounds without the risk of their evaporation, making it particularly suitable for thermo-sensitive compounds. Also, the elute can be used for further analysis using LC-HRMS. The effectiveness of the designed extraction assembly and technique was demonstrated by comparing the procedure with the available conventional extraction assemblies, highlighting the advantages of the developed method.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":632,"journal":{"name":"Journal of Food Science and Technology","volume":"62 1","pages":"65 - 74"},"PeriodicalIF":2.7010,"publicationDate":"2024-06-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Development of a positive pressure-based instrumentation for efficient solid phase extraction\",\"authors\":\"Pawankumar Rai, Srishti Mehrotra, Vaibhavi Lahane, Akhilesh K. Yadav, Sandeep K. Sharma\",\"doi\":\"10.1007/s13197-024-06010-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Solid phase extraction technique is a widely used sample preparation technique for the extraction of components from complex food matrices. However, there are several parameters in SPE that leads to low recovery, and reproducibility, insufficiently clean extracts and evaporation of volatile compounds. These drawbacks can be addressed through the use of innovative techniques and instrumentation that offers improved efficiency and accuracy for isolation of active constituents from food and beverage samples. Here a solid phase extraction methodology and extraction assembly has been developed for extracting compounds from orange fruit juice, followed by analysis using a LC-HRMS system. The methodology and assembly eliminate the evaporation step, thus facilitating the analysis of wide range of volatile and non-volatile compounds without the risk of their evaporation, making it particularly suitable for thermo-sensitive compounds. Also, the elute can be used for further analysis using LC-HRMS. The effectiveness of the designed extraction assembly and technique was demonstrated by comparing the procedure with the available conventional extraction assemblies, highlighting the advantages of the developed method.</p><h3>Graphical abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":632,\"journal\":{\"name\":\"Journal of Food Science and Technology\",\"volume\":\"62 1\",\"pages\":\"65 - 74\"},\"PeriodicalIF\":2.7010,\"publicationDate\":\"2024-06-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Food Science and Technology\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s13197-024-06010-3\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Food Science and Technology","FirstCategoryId":"1","ListUrlMain":"https://link.springer.com/article/10.1007/s13197-024-06010-3","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of a positive pressure-based instrumentation for efficient solid phase extraction
Solid phase extraction technique is a widely used sample preparation technique for the extraction of components from complex food matrices. However, there are several parameters in SPE that leads to low recovery, and reproducibility, insufficiently clean extracts and evaporation of volatile compounds. These drawbacks can be addressed through the use of innovative techniques and instrumentation that offers improved efficiency and accuracy for isolation of active constituents from food and beverage samples. Here a solid phase extraction methodology and extraction assembly has been developed for extracting compounds from orange fruit juice, followed by analysis using a LC-HRMS system. The methodology and assembly eliminate the evaporation step, thus facilitating the analysis of wide range of volatile and non-volatile compounds without the risk of their evaporation, making it particularly suitable for thermo-sensitive compounds. Also, the elute can be used for further analysis using LC-HRMS. The effectiveness of the designed extraction assembly and technique was demonstrated by comparing the procedure with the available conventional extraction assemblies, highlighting the advantages of the developed method.