直驱外转子混合动力-PM 通量切换发电机的精确 3D 热网开发

Ali Zarghani;Mohammad Farahzadi;Aghil Ghaheri;Karim Abbaszadeh
{"title":"直驱外转子混合动力-PM 通量切换发电机的精确 3D 热网开发","authors":"Ali Zarghani;Mohammad Farahzadi;Aghil Ghaheri;Karim Abbaszadeh","doi":"10.23919/CJEE.2024.000059","DOIUrl":null,"url":null,"abstract":"Heat and thermal problems are major obstacles to achieving high power density in compact permanent magnet (PM) topologies. Consequently, a comprehensive, accurate, and rapid temperature rise estimation method is required for novel electric machines to ensure safe and reliable operations. A unique three-dimensional (3D) lumped parameter thermal network (LPTN) is presented for accurate thermal modeling of a newly developed outer-rotor hybrid-PM flux switching generator (OR-HPMFSG) for direct-drive applications. First, the losses of the OR-HPMFSG are calculated using 3D finite element analysis (FEA). Subsequently, all machine components considering the thermal contact resistance, anisotropic thermal conductivity of materials, and various heat flow paths are comprehensively modeled based on the thermal resistances. In the proposed 3-D LPTN, internal nodes are considered to predict the average temperature as well as the hot spots of all active and passive components. Experimental measurements are performed on a prototype OR-HPMFSG to validate the efficiency of the 3-D LPTN. A comparison of the results at various operating points between the developed 3-D LPTN, experimental test, and FEA indicates that the 3-D LPTN quickly approximates the hotspot and mean temperature of all components under both transient and steady states with high accuracy.","PeriodicalId":36428,"journal":{"name":"Chinese Journal of Electrical Engineering","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10586892","citationCount":"0","resultStr":"{\"title\":\"Accurate 3D Thermal Network Development for Direct-Drive Outer-Rotor Hybrid-PM Flux-Switching Generator\",\"authors\":\"Ali Zarghani;Mohammad Farahzadi;Aghil Ghaheri;Karim Abbaszadeh\",\"doi\":\"10.23919/CJEE.2024.000059\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Heat and thermal problems are major obstacles to achieving high power density in compact permanent magnet (PM) topologies. Consequently, a comprehensive, accurate, and rapid temperature rise estimation method is required for novel electric machines to ensure safe and reliable operations. A unique three-dimensional (3D) lumped parameter thermal network (LPTN) is presented for accurate thermal modeling of a newly developed outer-rotor hybrid-PM flux switching generator (OR-HPMFSG) for direct-drive applications. First, the losses of the OR-HPMFSG are calculated using 3D finite element analysis (FEA). Subsequently, all machine components considering the thermal contact resistance, anisotropic thermal conductivity of materials, and various heat flow paths are comprehensively modeled based on the thermal resistances. In the proposed 3-D LPTN, internal nodes are considered to predict the average temperature as well as the hot spots of all active and passive components. Experimental measurements are performed on a prototype OR-HPMFSG to validate the efficiency of the 3-D LPTN. A comparison of the results at various operating points between the developed 3-D LPTN, experimental test, and FEA indicates that the 3-D LPTN quickly approximates the hotspot and mean temperature of all components under both transient and steady states with high accuracy.\",\"PeriodicalId\":36428,\"journal\":{\"name\":\"Chinese Journal of Electrical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10586892\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chinese Journal of Electrical Engineering\",\"FirstCategoryId\":\"1087\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10586892/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Engineering\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese Journal of Electrical Engineering","FirstCategoryId":"1087","ListUrlMain":"https://ieeexplore.ieee.org/document/10586892/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Engineering","Score":null,"Total":0}
引用次数: 0

摘要

热量和热问题是紧凑型永磁拓扑结构实现高功率密度的主要障碍。因此,新型电机需要一种全面、准确、快速的温升估算方法,以确保安全、可靠地运行。本文介绍了一种独特的三维(3D)叠加参数热网络(LPTN),用于对新开发的直驱应用外转子混合永磁磁通开关发电机(OR-HPMFSG)进行精确的热建模。首先,使用三维有限元分析(FEA)计算 OR-HPMFSG 的损耗。随后,考虑到热接触电阻、材料的各向异性热传导率和各种热流路径,根据热阻对所有机器部件进行了全面建模。在提议的三维 LPTN 中,考虑了内部节点,以预测所有主动和被动组件的平均温度和热点。对 OR-HPMFSG 原型进行了实验测量,以验证 3-D LPTN 的效率。对所开发的 3-D LPTN、实验测试和有限元分析在不同工作点的结果进行比较后发现,3-D LPTN 在瞬态和稳态下都能快速准确地近似所有组件的热点和平均温度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Accurate 3D Thermal Network Development for Direct-Drive Outer-Rotor Hybrid-PM Flux-Switching Generator
Heat and thermal problems are major obstacles to achieving high power density in compact permanent magnet (PM) topologies. Consequently, a comprehensive, accurate, and rapid temperature rise estimation method is required for novel electric machines to ensure safe and reliable operations. A unique three-dimensional (3D) lumped parameter thermal network (LPTN) is presented for accurate thermal modeling of a newly developed outer-rotor hybrid-PM flux switching generator (OR-HPMFSG) for direct-drive applications. First, the losses of the OR-HPMFSG are calculated using 3D finite element analysis (FEA). Subsequently, all machine components considering the thermal contact resistance, anisotropic thermal conductivity of materials, and various heat flow paths are comprehensively modeled based on the thermal resistances. In the proposed 3-D LPTN, internal nodes are considered to predict the average temperature as well as the hot spots of all active and passive components. Experimental measurements are performed on a prototype OR-HPMFSG to validate the efficiency of the 3-D LPTN. A comparison of the results at various operating points between the developed 3-D LPTN, experimental test, and FEA indicates that the 3-D LPTN quickly approximates the hotspot and mean temperature of all components under both transient and steady states with high accuracy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Chinese Journal of Electrical Engineering
Chinese Journal of Electrical Engineering Energy-Energy Engineering and Power Technology
CiteScore
7.80
自引率
0.00%
发文量
621
审稿时长
12 weeks
期刊最新文献
Front Cover Contents Wavelet Synchro-Squeezing Transform and Dynamic Threshold Supported Symmetrical Power Swing Technique for Modern Transmission Network Ice-Covered Environmental Adaptability Assessment for Overhead Contact System in High-Speed Railways Analytical Solution of a Fractional-Slot Double-Layer-Winding Open-Slot Vernier Permanent Magnet Machine with Tooth Tips
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1