针对散光眼和近视眼的宽视场光学眼模型。

IF 2 4区 心理学 Q2 OPHTHALMOLOGY Journal of Vision Pub Date : 2024-07-02 DOI:10.1167/jov.24.7.9
Gareth D Hastings, Pavan Tiruveedhula, Austin Roorda
{"title":"针对散光眼和近视眼的宽视场光学眼模型。","authors":"Gareth D Hastings, Pavan Tiruveedhula, Austin Roorda","doi":"10.1167/jov.24.7.9","DOIUrl":null,"url":null,"abstract":"<p><p>Ocular wavefront aberrations are used to describe retinal image formation in the study and modeling of foveal and peripheral visual functions and visual development. However, classical eye models generate aberration structures that generally do not resemble those of actual eyes, and simplifications such as rotationally symmetric and coaxial surfaces limit the usefulness of many modern eye models. Drawing on wide-field ocular wavefront aberrations measured previously by five laboratories, 28 emmetropic (-0.50 to +0.50 D) and 20 myopic (-1.50 to -4.50 D) individual optical eye models were reverse-engineered by optical design ray-tracing software. This involved an error function that manipulated 27 anatomical parameters, such as curvatures, asphericities, thicknesses, tilts, and translations-constrained within anatomical limits-to drive the output aberrations of each model to agree with the input (measured) aberrations. From those resultant anatomical parameters, three representative eye models were also defined: an ideal emmetropic eye with minimal aberrations (0.00 D), as well as a typical emmetropic eye (-0.02 D) and myopic eye (-2.75 D). The cohorts and individual models are presented and evaluated in terms of output aberrations and established population expectations, such as Seidel aberration theory and ocular chromatic aberrations. Presented applications of the models include the effect of dual focus contact lenses on peripheral optical quality, the comparison of ophthalmic correction modalities, and the projection of object space across the retina during accommodation.</p>","PeriodicalId":49955,"journal":{"name":"Journal of Vision","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11246097/pdf/","citationCount":"0","resultStr":"{\"title\":\"Wide-field optical eye models for emmetropic and myopic eyes.\",\"authors\":\"Gareth D Hastings, Pavan Tiruveedhula, Austin Roorda\",\"doi\":\"10.1167/jov.24.7.9\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Ocular wavefront aberrations are used to describe retinal image formation in the study and modeling of foveal and peripheral visual functions and visual development. However, classical eye models generate aberration structures that generally do not resemble those of actual eyes, and simplifications such as rotationally symmetric and coaxial surfaces limit the usefulness of many modern eye models. Drawing on wide-field ocular wavefront aberrations measured previously by five laboratories, 28 emmetropic (-0.50 to +0.50 D) and 20 myopic (-1.50 to -4.50 D) individual optical eye models were reverse-engineered by optical design ray-tracing software. This involved an error function that manipulated 27 anatomical parameters, such as curvatures, asphericities, thicknesses, tilts, and translations-constrained within anatomical limits-to drive the output aberrations of each model to agree with the input (measured) aberrations. From those resultant anatomical parameters, three representative eye models were also defined: an ideal emmetropic eye with minimal aberrations (0.00 D), as well as a typical emmetropic eye (-0.02 D) and myopic eye (-2.75 D). The cohorts and individual models are presented and evaluated in terms of output aberrations and established population expectations, such as Seidel aberration theory and ocular chromatic aberrations. Presented applications of the models include the effect of dual focus contact lenses on peripheral optical quality, the comparison of ophthalmic correction modalities, and the projection of object space across the retina during accommodation.</p>\",\"PeriodicalId\":49955,\"journal\":{\"name\":\"Journal of Vision\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11246097/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Vision\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1167/jov.24.7.9\",\"RegionNum\":4,\"RegionCategory\":\"心理学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Vision","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1167/jov.24.7.9","RegionNum":4,"RegionCategory":"心理学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

在研究和模拟眼窝和周边视觉功能以及视觉发育的过程中,眼波前像差被用来描述视网膜图像的形成。然而,经典眼球模型产生的像差结构通常与实际眼球结构并不相似,旋转对称和同轴表面等简化限制了许多现代眼球模型的实用性。根据五个实验室之前测量的宽视场眼球波前像差,用光学设计光线跟踪软件反向设计了 28 个散光(-0.50 到 +0.50 D)和 20 个近视(-1.50 到 -4.50 D)单个光学眼球模型。这涉及一个误差函数,该函数操纵 27 个解剖参数,如曲率、非球面度、厚度、倾斜度和平移--在解剖学限制范围内进行约束--使每个模型的输出像差与输入(测量)像差一致。根据这些解剖参数,还定义了三个代表性眼球模型:具有最小像差(0.00 D)的理想散光眼,以及典型散光眼(-0.02 D)和近视眼(-2.75 D)。根据输出像差和既定的群体预期(如 Seidel 像差理论和眼色差),对队列和单个模型进行了介绍和评估。介绍的模型应用包括双焦点隐形眼镜对周边光学质量的影响、眼科矫正模式的比较以及在调节过程中物体空间在视网膜上的投影。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Wide-field optical eye models for emmetropic and myopic eyes.

Ocular wavefront aberrations are used to describe retinal image formation in the study and modeling of foveal and peripheral visual functions and visual development. However, classical eye models generate aberration structures that generally do not resemble those of actual eyes, and simplifications such as rotationally symmetric and coaxial surfaces limit the usefulness of many modern eye models. Drawing on wide-field ocular wavefront aberrations measured previously by five laboratories, 28 emmetropic (-0.50 to +0.50 D) and 20 myopic (-1.50 to -4.50 D) individual optical eye models were reverse-engineered by optical design ray-tracing software. This involved an error function that manipulated 27 anatomical parameters, such as curvatures, asphericities, thicknesses, tilts, and translations-constrained within anatomical limits-to drive the output aberrations of each model to agree with the input (measured) aberrations. From those resultant anatomical parameters, three representative eye models were also defined: an ideal emmetropic eye with minimal aberrations (0.00 D), as well as a typical emmetropic eye (-0.02 D) and myopic eye (-2.75 D). The cohorts and individual models are presented and evaluated in terms of output aberrations and established population expectations, such as Seidel aberration theory and ocular chromatic aberrations. Presented applications of the models include the effect of dual focus contact lenses on peripheral optical quality, the comparison of ophthalmic correction modalities, and the projection of object space across the retina during accommodation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Vision
Journal of Vision 医学-眼科学
CiteScore
2.90
自引率
5.60%
发文量
218
审稿时长
3-6 weeks
期刊介绍: Exploring all aspects of biological visual function, including spatial vision, perception, low vision, color vision and more, spanning the fields of neuroscience, psychology and psychophysics.
期刊最新文献
Individual differences reveal similarities in serial dependence effects across perceptual tasks, but not to oculomotor tasks. Investigating the relationship between subjective perception and unconscious feature integration. Binocular integration of chromatic and luminance signals. Deep convolutional neural networks are sensitive to face configuration. How the window of visibility varies around polar angle.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1