Ândrea de Melo Boaz, Rudimar Dos Santos Riesgo, Pricila Sleifer
{"title":"Horus® 计算机化儿童体位测量法的标准值。","authors":"Ândrea de Melo Boaz, Rudimar Dos Santos Riesgo, Pricila Sleifer","doi":"10.1590/2317-1782/20242023241pt","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Propose normalization values of the Horus® computerized posturography platform, in children aged 4 to 6 years, without auditory and/or vestibular complaints.</p><p><strong>Methods: </strong>Cross-sectional study, 216 children aged 4 to 6 years participated. All the children underwent to visual screening, audiological evaluation and computerized posturography, which consists of research on stability limits and seven sensory conditions. The results were statistically analyzed using the tests non-parametric Kruskal-Walli, post hoc Dunn-Bonferroni for pairwise age comparisons and the Mann-Whitney U for sex analysis. Categorical data were presented in relative frequency and quantitative data in mean and standard deviation.</p><p><strong>Results: </strong>Standardization values were described for the stability limit and for the seven sensory conditions. There was a difference for the stability limit between sex at 4 years old(p<0.007) and, in the comparison between ages 4 and 5 (p=0.005) and 4 and 6 years old(p<0.001). In the residual functional balance, comparison between ages, there was a difference between 4 and 5, 4 and 6, 5 and 6 years, however for different data. The presence of statistical difference for different evaluation data also occurred in the analysis by sex. In the sensory systems, the findings between ages showed differences for the vestibular system, right and left optokinetic visual dependence, tunnel visual dependence and for the composite balance index.</p><p><strong>Conclusion: </strong>It was possible to establish normative values for the Horus® posturography in healthy children aged 4 to 6 years.</p>","PeriodicalId":46547,"journal":{"name":"CoDAS","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2024-08-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11340877/pdf/","citationCount":"0","resultStr":"{\"title\":\"Normative values to Horus® computerized posturography in children.\",\"authors\":\"Ândrea de Melo Boaz, Rudimar Dos Santos Riesgo, Pricila Sleifer\",\"doi\":\"10.1590/2317-1782/20242023241pt\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Propose normalization values of the Horus® computerized posturography platform, in children aged 4 to 6 years, without auditory and/or vestibular complaints.</p><p><strong>Methods: </strong>Cross-sectional study, 216 children aged 4 to 6 years participated. All the children underwent to visual screening, audiological evaluation and computerized posturography, which consists of research on stability limits and seven sensory conditions. The results were statistically analyzed using the tests non-parametric Kruskal-Walli, post hoc Dunn-Bonferroni for pairwise age comparisons and the Mann-Whitney U for sex analysis. Categorical data were presented in relative frequency and quantitative data in mean and standard deviation.</p><p><strong>Results: </strong>Standardization values were described for the stability limit and for the seven sensory conditions. There was a difference for the stability limit between sex at 4 years old(p<0.007) and, in the comparison between ages 4 and 5 (p=0.005) and 4 and 6 years old(p<0.001). In the residual functional balance, comparison between ages, there was a difference between 4 and 5, 4 and 6, 5 and 6 years, however for different data. The presence of statistical difference for different evaluation data also occurred in the analysis by sex. In the sensory systems, the findings between ages showed differences for the vestibular system, right and left optokinetic visual dependence, tunnel visual dependence and for the composite balance index.</p><p><strong>Conclusion: </strong>It was possible to establish normative values for the Horus® posturography in healthy children aged 4 to 6 years.</p>\",\"PeriodicalId\":46547,\"journal\":{\"name\":\"CoDAS\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.9000,\"publicationDate\":\"2024-08-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11340877/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CoDAS\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/2317-1782/20242023241pt\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q4\",\"JCRName\":\"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CoDAS","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/2317-1782/20242023241pt","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"AUDIOLOGY & SPEECH-LANGUAGE PATHOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的:针对无听觉和/或前庭不适的 4-6 岁儿童,提出 Horus® 电脑体位测量平台的正常值:方法:横断面研究,共有 216 名 4-6 岁儿童参与。所有儿童都接受了视力筛查、听力评估和电脑体位测量,其中包括对稳定性极限和七种感觉条件的研究。研究结果采用非参数 Kruskal-Walli 检验法进行统计分析,在进行成对年龄比较时采用 post hoc Dunn-Bonferroni 检验法,在进行性别分析时采用 Mann-Whitney U 检验法。分类数据以相对频率表示,定量数据以平均值和标准偏差表示:描述了稳定极限和七种感官条件的标准化值。结果:描述了稳定性极限和七种感觉条件的标准化值,4 岁儿童的稳定性极限在性别上存在差异(p):可以为 4 至 6 岁健康儿童的 Horus® 体位法确定标准值。
Normative values to Horus® computerized posturography in children.
Purpose: Propose normalization values of the Horus® computerized posturography platform, in children aged 4 to 6 years, without auditory and/or vestibular complaints.
Methods: Cross-sectional study, 216 children aged 4 to 6 years participated. All the children underwent to visual screening, audiological evaluation and computerized posturography, which consists of research on stability limits and seven sensory conditions. The results were statistically analyzed using the tests non-parametric Kruskal-Walli, post hoc Dunn-Bonferroni for pairwise age comparisons and the Mann-Whitney U for sex analysis. Categorical data were presented in relative frequency and quantitative data in mean and standard deviation.
Results: Standardization values were described for the stability limit and for the seven sensory conditions. There was a difference for the stability limit between sex at 4 years old(p<0.007) and, in the comparison between ages 4 and 5 (p=0.005) and 4 and 6 years old(p<0.001). In the residual functional balance, comparison between ages, there was a difference between 4 and 5, 4 and 6, 5 and 6 years, however for different data. The presence of statistical difference for different evaluation data also occurred in the analysis by sex. In the sensory systems, the findings between ages showed differences for the vestibular system, right and left optokinetic visual dependence, tunnel visual dependence and for the composite balance index.
Conclusion: It was possible to establish normative values for the Horus® posturography in healthy children aged 4 to 6 years.