{"title":"比较颈内静脉插管的短轴与长轴超声引导技术:临床结果和安全性的荟萃分析","authors":"Faisal AlGhamdi, Nasser AlJoaib, Ali Aldawood, Mohammed AlGhamdi, Abdullah AlMulhim","doi":"10.1002/ajum.12385","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Introduction</h3>\n \n <p>Central venous access plays a crucial role in various clinical settings, and ultrasound guidance has become increasingly popular for improving its safety and success rates. The aim of this meta-analysis was to compare the short-axis (SAX) and long-axis (LAX) ultrasound-guided techniques for internal jugular vein (IJV) cannulation in terms of first needle pass success rate, number of cannulation attempts, access time, guidewire insertion time, posterior IJV wall puncture, arterial puncture, haematoma and catheter-related bloodstream infection.</p>\n </section>\n \n <section>\n \n <h3> Methods</h3>\n \n <p>A comprehensive literature search was conducted, and randomised controlled trials (RCTs) comparing SAX and LAX techniques for IJV cannulation on adults were included.</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>A total of 11 RCTs involving 1183 patients were included in the meta-analysis. The SAX technique demonstrated a significantly greater first needle pass success rate and faster IJV access time compared to the LAX technique. However, more posterior IJV wall puncture was significantly associated with the SAX technique. There was no significant difference between the two techniques in terms of number of cannulation attempts, guidewire insertion time, arterial puncture, haematoma and catheter-related bloodstream infection.</p>\n </section>\n \n <section>\n \n <h3> Conclusion</h3>\n \n <p>This meta-analysis suggests that the SAX technique may have advantages over the LAX technique in terms of first needle pass success rate and potentially reducing cannulation attempts and access time. However, the occurrence of posterior IJV wall puncture raises concerns. The decision on the choice of technique should be based on individual patient factors and operator proficiency.</p>\n </section>\n </div>","PeriodicalId":36517,"journal":{"name":"Australasian Journal of Ultrasound in Medicine","volume":"27 3","pages":"149-158"},"PeriodicalIF":0.0000,"publicationDate":"2024-04-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Comparing short-axis versus long-axis ultrasound-guided techniques for internal jugular vein cannulation: A meta-analysis of clinical outcomes and safety\",\"authors\":\"Faisal AlGhamdi, Nasser AlJoaib, Ali Aldawood, Mohammed AlGhamdi, Abdullah AlMulhim\",\"doi\":\"10.1002/ajum.12385\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Introduction</h3>\\n \\n <p>Central venous access plays a crucial role in various clinical settings, and ultrasound guidance has become increasingly popular for improving its safety and success rates. The aim of this meta-analysis was to compare the short-axis (SAX) and long-axis (LAX) ultrasound-guided techniques for internal jugular vein (IJV) cannulation in terms of first needle pass success rate, number of cannulation attempts, access time, guidewire insertion time, posterior IJV wall puncture, arterial puncture, haematoma and catheter-related bloodstream infection.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Methods</h3>\\n \\n <p>A comprehensive literature search was conducted, and randomised controlled trials (RCTs) comparing SAX and LAX techniques for IJV cannulation on adults were included.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>A total of 11 RCTs involving 1183 patients were included in the meta-analysis. The SAX technique demonstrated a significantly greater first needle pass success rate and faster IJV access time compared to the LAX technique. However, more posterior IJV wall puncture was significantly associated with the SAX technique. There was no significant difference between the two techniques in terms of number of cannulation attempts, guidewire insertion time, arterial puncture, haematoma and catheter-related bloodstream infection.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusion</h3>\\n \\n <p>This meta-analysis suggests that the SAX technique may have advantages over the LAX technique in terms of first needle pass success rate and potentially reducing cannulation attempts and access time. However, the occurrence of posterior IJV wall puncture raises concerns. The decision on the choice of technique should be based on individual patient factors and operator proficiency.</p>\\n </section>\\n </div>\",\"PeriodicalId\":36517,\"journal\":{\"name\":\"Australasian Journal of Ultrasound in Medicine\",\"volume\":\"27 3\",\"pages\":\"149-158\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-04-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Australasian Journal of Ultrasound in Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/ajum.12385\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Australasian Journal of Ultrasound in Medicine","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/ajum.12385","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Comparing short-axis versus long-axis ultrasound-guided techniques for internal jugular vein cannulation: A meta-analysis of clinical outcomes and safety
Introduction
Central venous access plays a crucial role in various clinical settings, and ultrasound guidance has become increasingly popular for improving its safety and success rates. The aim of this meta-analysis was to compare the short-axis (SAX) and long-axis (LAX) ultrasound-guided techniques for internal jugular vein (IJV) cannulation in terms of first needle pass success rate, number of cannulation attempts, access time, guidewire insertion time, posterior IJV wall puncture, arterial puncture, haematoma and catheter-related bloodstream infection.
Methods
A comprehensive literature search was conducted, and randomised controlled trials (RCTs) comparing SAX and LAX techniques for IJV cannulation on adults were included.
Results
A total of 11 RCTs involving 1183 patients were included in the meta-analysis. The SAX technique demonstrated a significantly greater first needle pass success rate and faster IJV access time compared to the LAX technique. However, more posterior IJV wall puncture was significantly associated with the SAX technique. There was no significant difference between the two techniques in terms of number of cannulation attempts, guidewire insertion time, arterial puncture, haematoma and catheter-related bloodstream infection.
Conclusion
This meta-analysis suggests that the SAX technique may have advantages over the LAX technique in terms of first needle pass success rate and potentially reducing cannulation attempts and access time. However, the occurrence of posterior IJV wall puncture raises concerns. The decision on the choice of technique should be based on individual patient factors and operator proficiency.