Hu Hou, Jianguo Zhang, Song Huang, Fengling Hu, Youcheng Yu, Liang Song
{"title":"基台孔锥位和螺钉锥角对种植体系统和种植体周围组织的力学影响:有限元分析。","authors":"Hu Hou, Jianguo Zhang, Song Huang, Fengling Hu, Youcheng Yu, Liang Song","doi":"10.1080/10255842.2024.2423253","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The study aimed to investigate the mechanical effects of the taper position in the abutment hole and the screw taper angles on the implant system and peri-implant tissue using finite element analysis.</p><p><strong>Methods: </strong>Four taper positions (L1, L2, L3, L4) in the abutment hole were established using 3D software and five screw taper angles (30°, 60°, 90°, 120°, 180°) were set.</p><p><strong>Result: </strong>Taper position significantly affects the stresses in the implant system. The 30° and 180° angles (L4 position) showed less stress than other angles.</p><p><strong>Conclusion: </strong>Elevated taper position and reasonable taper angle are beneficial in reducing the stress in the implant system.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-11-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis.\",\"authors\":\"Hu Hou, Jianguo Zhang, Song Huang, Fengling Hu, Youcheng Yu, Liang Song\",\"doi\":\"10.1080/10255842.2024.2423253\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The study aimed to investigate the mechanical effects of the taper position in the abutment hole and the screw taper angles on the implant system and peri-implant tissue using finite element analysis.</p><p><strong>Methods: </strong>Four taper positions (L1, L2, L3, L4) in the abutment hole were established using 3D software and five screw taper angles (30°, 60°, 90°, 120°, 180°) were set.</p><p><strong>Result: </strong>Taper position significantly affects the stresses in the implant system. The 30° and 180° angles (L4 position) showed less stress than other angles.</p><p><strong>Conclusion: </strong>Elevated taper position and reasonable taper angle are beneficial in reducing the stress in the implant system.</p>\",\"PeriodicalId\":50640,\"journal\":{\"name\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-11-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10255842.2024.2423253\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2024.2423253","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis.
Purpose: The study aimed to investigate the mechanical effects of the taper position in the abutment hole and the screw taper angles on the implant system and peri-implant tissue using finite element analysis.
Methods: Four taper positions (L1, L2, L3, L4) in the abutment hole were established using 3D software and five screw taper angles (30°, 60°, 90°, 120°, 180°) were set.
Result: Taper position significantly affects the stresses in the implant system. The 30° and 180° angles (L4 position) showed less stress than other angles.
Conclusion: Elevated taper position and reasonable taper angle are beneficial in reducing the stress in the implant system.
期刊介绍:
The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.