William T Williams, Kathryn Lindley, Hong Liao, Lynn Kamen, Michelle Miller, Amanda Hays, Jeffrey Sailstad
{"title":"建立一种有效的新型蛋白头提取方法,用于检测人血清中的抗聚乙二醇抗体。","authors":"William T Williams, Kathryn Lindley, Hong Liao, Lynn Kamen, Michelle Miller, Amanda Hays, Jeffrey Sailstad","doi":"10.1080/17576180.2024.2442198","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>Polyethylene glycol (PEG) is used in many applications including drug development. Due to exposure to environmental products, there is a high prevalence of preexisting anti-PEG antibodies in the global human population. The presence of anti-PEG antibodies is a concern for potentially reducing the efficacy of therapeutics after administration and represents a risk of safety events after exposure to PEGylated drug products. We developed and validated a creative and sensitive method for the detection of anti-PEG antibodies in human serum to support clinical programs for PEGylated drugs.</p><p><strong>Methods: </strong>In this method, biotin-PEG streptavidin beads were used to extract anti-PEG antibodies from human serum for analysis in an anti-PEG ELISA assay. The same serum sample was analyzed in an anti-drug antibody assay.</p><p><strong>Results: </strong>The anti-PEG antibody assay was validated with a screening cut point of 1.41 normalized signal, confirmatory cut point of 32.2% inhibition, sensitivity of 7.81 ng/mL and sufficient reproducibility, selectivity, and drug tolerance in accordance with the FDA 2019 Immunogenicity guidance.</p><p><strong>Conclusion: </strong>This method of removal of anti-PEG antibodies enables the use of a single sample to detect anti-drug and anti-PEG antibodies to support drug development programs.</p>","PeriodicalId":8797,"journal":{"name":"Bioanalysis","volume":" ","pages":"7-15"},"PeriodicalIF":1.9000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11749383/pdf/","citationCount":"0","resultStr":"{\"title\":\"Development of a validated novel bead extraction method for the detection of anti-PEG antibodies in human serum.\",\"authors\":\"William T Williams, Kathryn Lindley, Hong Liao, Lynn Kamen, Michelle Miller, Amanda Hays, Jeffrey Sailstad\",\"doi\":\"10.1080/17576180.2024.2442198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>Polyethylene glycol (PEG) is used in many applications including drug development. Due to exposure to environmental products, there is a high prevalence of preexisting anti-PEG antibodies in the global human population. The presence of anti-PEG antibodies is a concern for potentially reducing the efficacy of therapeutics after administration and represents a risk of safety events after exposure to PEGylated drug products. We developed and validated a creative and sensitive method for the detection of anti-PEG antibodies in human serum to support clinical programs for PEGylated drugs.</p><p><strong>Methods: </strong>In this method, biotin-PEG streptavidin beads were used to extract anti-PEG antibodies from human serum for analysis in an anti-PEG ELISA assay. The same serum sample was analyzed in an anti-drug antibody assay.</p><p><strong>Results: </strong>The anti-PEG antibody assay was validated with a screening cut point of 1.41 normalized signal, confirmatory cut point of 32.2% inhibition, sensitivity of 7.81 ng/mL and sufficient reproducibility, selectivity, and drug tolerance in accordance with the FDA 2019 Immunogenicity guidance.</p><p><strong>Conclusion: </strong>This method of removal of anti-PEG antibodies enables the use of a single sample to detect anti-drug and anti-PEG antibodies to support drug development programs.</p>\",\"PeriodicalId\":8797,\"journal\":{\"name\":\"Bioanalysis\",\"volume\":\" \",\"pages\":\"7-15\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2025-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11749383/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bioanalysis\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/17576180.2024.2442198\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/12/18 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bioanalysis","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/17576180.2024.2442198","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/12/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Development of a validated novel bead extraction method for the detection of anti-PEG antibodies in human serum.
Aims: Polyethylene glycol (PEG) is used in many applications including drug development. Due to exposure to environmental products, there is a high prevalence of preexisting anti-PEG antibodies in the global human population. The presence of anti-PEG antibodies is a concern for potentially reducing the efficacy of therapeutics after administration and represents a risk of safety events after exposure to PEGylated drug products. We developed and validated a creative and sensitive method for the detection of anti-PEG antibodies in human serum to support clinical programs for PEGylated drugs.
Methods: In this method, biotin-PEG streptavidin beads were used to extract anti-PEG antibodies from human serum for analysis in an anti-PEG ELISA assay. The same serum sample was analyzed in an anti-drug antibody assay.
Results: The anti-PEG antibody assay was validated with a screening cut point of 1.41 normalized signal, confirmatory cut point of 32.2% inhibition, sensitivity of 7.81 ng/mL and sufficient reproducibility, selectivity, and drug tolerance in accordance with the FDA 2019 Immunogenicity guidance.
Conclusion: This method of removal of anti-PEG antibodies enables the use of a single sample to detect anti-drug and anti-PEG antibodies to support drug development programs.
BioanalysisBIOCHEMICAL RESEARCH METHODS-CHEMISTRY, ANALYTICAL
CiteScore
3.30
自引率
16.70%
发文量
88
审稿时长
2 months
期刊介绍:
Reliable data obtained from selective, sensitive and reproducible analysis of xenobiotics and biotics in biological samples is a fundamental and crucial part of every successful drug development program. The same principles can also apply to many other areas of research such as forensic science, toxicology and sports doping testing.
The bioanalytical field incorporates sophisticated techniques linking sample preparation and advanced separations with MS and NMR detection systems, automation and robotics. Standards set by regulatory bodies regarding method development and validation increasingly define the boundaries between speed and quality.
Bioanalysis is a progressive discipline for which the future holds many exciting opportunities to further reduce sample volumes, analysis cost and environmental impact, as well as to improve sensitivity, specificity, accuracy, efficiency, assay throughput, data quality, data handling and processing.
The journal Bioanalysis focuses on the techniques and methods used for the detection or quantitative study of analytes in human or animal biological samples. Bioanalysis encourages the submission of articles describing forward-looking applications, including biosensors, microfluidics, miniaturized analytical devices, and new hyphenated and multi-dimensional techniques.
Bioanalysis delivers essential information in concise, at-a-glance article formats. Key advances in the field are reported and analyzed by international experts, providing an authoritative but accessible forum for the modern bioanalyst.