结合RCA-HCR级联扩增和CRISPR/Cas12a,基于商用HCG条带的POCT检测miRNA21

IF 5.3 2区 化学 Q1 CHEMISTRY, ANALYTICAL Microchimica Acta Pub Date : 2025-01-14 DOI:10.1007/s00604-024-06922-z
Yuan Li, Zhihui Zeng, Xuefei Lv, Hao Jiang, Anyi Li, Ying Liu, Yulin Deng, Xiaoqiong Li
{"title":"结合RCA-HCR级联扩增和CRISPR/Cas12a,基于商用HCG条带的POCT检测miRNA21","authors":"Yuan Li,&nbsp;Zhihui Zeng,&nbsp;Xuefei Lv,&nbsp;Hao Jiang,&nbsp;Anyi Li,&nbsp;Ying Liu,&nbsp;Yulin Deng,&nbsp;Xiaoqiong Li","doi":"10.1007/s00604-024-06922-z","DOIUrl":null,"url":null,"abstract":"<div><p> A point-of-care testing (POCT) assay based on commercial HCG strip was proposed for miRNA21 detection by integrating RCA-HCR cascaded isothermal amplification with CRISPR/Cas12a. Three modules were integrated in the proposed platform: target amplification module composed of rolling circle amplification (RCA) cascaded with hybridization chain reaction (HCR), signal transduction module composed of CRISPR/Cas12a combined with HCG-agarose gel beads probes, and signal readout module composed of commercial HCG strips. The proposed RCA-HCR-CRISPR/Cas12a-HCG strip assay for miRNA21 detection had high sensitivity, and the limit of detection was as low as 37 fM. The proposed assay showed excellent specificity for miRNA21, as other miRNAs did not caused interference for detection. The recoveries of miRNA21 were ranged from 89.0 to 118.0%. The intra-batch and inter-batch coefficient of variation (CV) were 10.1–13.4% and 11.9–14.5%, respectively, which indicated a high accuracy and precision, and the serum matrix did not cause any interference. With the advantages of low-cost, high sensitivity, visualization, and easy popularization, the proposed assay is expected to provide a powerful tool for early diagnosis of tumor disease miRNA, especially in resource-limited areas.</p><h3>Graphical abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":705,"journal":{"name":"Microchimica Acta","volume":"192 2","pages":""},"PeriodicalIF":5.3000,"publicationDate":"2025-01-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A POCT assay based on commercial HCG strip for miRNA21 detection by integrating with RCA-HCR cascade amplification and CRISPR/Cas12a\",\"authors\":\"Yuan Li,&nbsp;Zhihui Zeng,&nbsp;Xuefei Lv,&nbsp;Hao Jiang,&nbsp;Anyi Li,&nbsp;Ying Liu,&nbsp;Yulin Deng,&nbsp;Xiaoqiong Li\",\"doi\":\"10.1007/s00604-024-06922-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p> A point-of-care testing (POCT) assay based on commercial HCG strip was proposed for miRNA21 detection by integrating RCA-HCR cascaded isothermal amplification with CRISPR/Cas12a. Three modules were integrated in the proposed platform: target amplification module composed of rolling circle amplification (RCA) cascaded with hybridization chain reaction (HCR), signal transduction module composed of CRISPR/Cas12a combined with HCG-agarose gel beads probes, and signal readout module composed of commercial HCG strips. The proposed RCA-HCR-CRISPR/Cas12a-HCG strip assay for miRNA21 detection had high sensitivity, and the limit of detection was as low as 37 fM. The proposed assay showed excellent specificity for miRNA21, as other miRNAs did not caused interference for detection. The recoveries of miRNA21 were ranged from 89.0 to 118.0%. The intra-batch and inter-batch coefficient of variation (CV) were 10.1–13.4% and 11.9–14.5%, respectively, which indicated a high accuracy and precision, and the serum matrix did not cause any interference. With the advantages of low-cost, high sensitivity, visualization, and easy popularization, the proposed assay is expected to provide a powerful tool for early diagnosis of tumor disease miRNA, especially in resource-limited areas.</p><h3>Graphical abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":705,\"journal\":{\"name\":\"Microchimica Acta\",\"volume\":\"192 2\",\"pages\":\"\"},\"PeriodicalIF\":5.3000,\"publicationDate\":\"2025-01-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Microchimica Acta\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s00604-024-06922-z\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Microchimica Acta","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s00604-024-06922-z","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种基于商用HCG试纸的POCT检测方法,该方法将RCA-HCR级联等温扩增与CRISPR/Cas12a结合,用于miRNA21的检测。该平台集成了三个模块:由滚圈扩增(RCA)级联杂交链反应(HCR)组成的靶扩增模块,由CRISPR/Cas12a结合HCG-琼脂糖凝胶珠探针组成的信号转导模块,以及由商用HCG条带组成的信号读出模块。所建立的RCA-HCR-CRISPR/Cas12a-HCG条带法检测miRNA21灵敏度高,检出限低至37 fM。由于其他miRNAs不会对检测产生干扰,因此所提出的检测方法对miRNA21具有出色的特异性。miRNA21的加样回收率为89.0% ~ 118.0%。批内变异系数(CV)为10.1 ~ 13.4%,批间变异系数(CV)为11.9 ~ 14.5%,具有较高的准确度和精密度,且血清基质不产生干扰。该检测方法具有成本低、灵敏度高、可视化、易于推广等优点,有望为肿瘤疾病miRNA的早期诊断提供有力的工具,特别是在资源有限的地区。图形抽象
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A POCT assay based on commercial HCG strip for miRNA21 detection by integrating with RCA-HCR cascade amplification and CRISPR/Cas12a

A point-of-care testing (POCT) assay based on commercial HCG strip was proposed for miRNA21 detection by integrating RCA-HCR cascaded isothermal amplification with CRISPR/Cas12a. Three modules were integrated in the proposed platform: target amplification module composed of rolling circle amplification (RCA) cascaded with hybridization chain reaction (HCR), signal transduction module composed of CRISPR/Cas12a combined with HCG-agarose gel beads probes, and signal readout module composed of commercial HCG strips. The proposed RCA-HCR-CRISPR/Cas12a-HCG strip assay for miRNA21 detection had high sensitivity, and the limit of detection was as low as 37 fM. The proposed assay showed excellent specificity for miRNA21, as other miRNAs did not caused interference for detection. The recoveries of miRNA21 were ranged from 89.0 to 118.0%. The intra-batch and inter-batch coefficient of variation (CV) were 10.1–13.4% and 11.9–14.5%, respectively, which indicated a high accuracy and precision, and the serum matrix did not cause any interference. With the advantages of low-cost, high sensitivity, visualization, and easy popularization, the proposed assay is expected to provide a powerful tool for early diagnosis of tumor disease miRNA, especially in resource-limited areas.

Graphical abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Microchimica Acta
Microchimica Acta 化学-分析化学
CiteScore
9.80
自引率
5.30%
发文量
410
审稿时长
2.7 months
期刊介绍: As a peer-reviewed journal for analytical sciences and technologies on the micro- and nanoscale, Microchimica Acta has established itself as a premier forum for truly novel approaches in chemical and biochemical analysis. Coverage includes methods and devices that provide expedient solutions to the most contemporary demands in this area. Examples are point-of-care technologies, wearable (bio)sensors, in-vivo-monitoring, micro/nanomotors and materials based on synthetic biology as well as biomedical imaging and targeting.
期刊最新文献
Confined active area and aggregation kinetic-based AuNPs@PVP nanosensors for simultaneous colorimetric detection of cysteine and homocysteine as homologues in human urine and serum. Electrochemical aptasensor for the selective detection of vancomycin based on nanostructured "in-lab" printed electrodes. Preparation of CHS-Fe3O4@@ZIF-8 peroxidase-mimic with an ultra-thin hollow layer for ultrasensitive electrochemical detection of kanamycin. Aptamer-antibody sandwich immunosensor for electrochemical detection of FT4. Nanoenzyme-based sensors for the detection of anti-tumor drugs.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1