发动机使用前后防冻性能分析

Oleg I. Telkov, Anastasia D. Kosmacheva, A. Khodyakov, S. Khlopkov, I. Danilov
{"title":"发动机使用前后防冻性能分析","authors":"Oleg I. Telkov, Anastasia D. Kosmacheva, A. Khodyakov, S. Khlopkov, I. Danilov","doi":"10.22363/2312-8143-2021-22-4-329-338","DOIUrl":null,"url":null,"abstract":"The results of diagnostics of antifreeze indicators before and after their operation in an internal combustion engine are presented. The chosen direction of research is relevant, since it allows one to predict not only the change in the properties of antifreeze during its operation, but also to obtain evidence of the course of metal corrosion processes. The purpose of the study - to conduct control tests of antifreezes before and after their operation in an internal combustion engine, that ensures the maintenance of the power unit in good condition. The objects of study were fresh AGA Z-40-G12++ antifreeze (release of 2021; A-21) and coolant AGA Z-40-G12+ (release of 2012; AE-12) after its operation for several years. It is shown that the pH, density, viscosity, electrical conductivity of the coolant samples before and after its operation are different. It was found that the course of the dependences of electrical conductivity on temperature t for samples A-21 and AE-12 is the same. The dependence of on t is described by a polynomial (quadratic) model. It has been suggested that higher values of the AE-12 hydrogen index may indicate the occurrence of electrochemical corrosion of metals, which, in the process of contact with antifreeze, form short-circuited galvanic pairs. With the help of a complete factorial experiment, it was demonstrated that higher pH values of used antifreeze can be a reflection of the degradation of the properties of monoethylene glycol and the ongoing processes of metal corrosion.","PeriodicalId":53011,"journal":{"name":"RUDN Journal of Engineering Researches","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-12-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of antifreeze properties before and after their operation in engine\",\"authors\":\"Oleg I. Telkov, Anastasia D. Kosmacheva, A. Khodyakov, S. Khlopkov, I. Danilov\",\"doi\":\"10.22363/2312-8143-2021-22-4-329-338\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The results of diagnostics of antifreeze indicators before and after their operation in an internal combustion engine are presented. The chosen direction of research is relevant, since it allows one to predict not only the change in the properties of antifreeze during its operation, but also to obtain evidence of the course of metal corrosion processes. The purpose of the study - to conduct control tests of antifreezes before and after their operation in an internal combustion engine, that ensures the maintenance of the power unit in good condition. The objects of study were fresh AGA Z-40-G12++ antifreeze (release of 2021; A-21) and coolant AGA Z-40-G12+ (release of 2012; AE-12) after its operation for several years. It is shown that the pH, density, viscosity, electrical conductivity of the coolant samples before and after its operation are different. It was found that the course of the dependences of electrical conductivity on temperature t for samples A-21 and AE-12 is the same. The dependence of on t is described by a polynomial (quadratic) model. It has been suggested that higher values of the AE-12 hydrogen index may indicate the occurrence of electrochemical corrosion of metals, which, in the process of contact with antifreeze, form short-circuited galvanic pairs. With the help of a complete factorial experiment, it was demonstrated that higher pH values of used antifreeze can be a reflection of the degradation of the properties of monoethylene glycol and the ongoing processes of metal corrosion.\",\"PeriodicalId\":53011,\"journal\":{\"name\":\"RUDN Journal of Engineering Researches\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-12-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"RUDN Journal of Engineering Researches\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.22363/2312-8143-2021-22-4-329-338\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"RUDN Journal of Engineering Researches","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22363/2312-8143-2021-22-4-329-338","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了内燃机防冻指示器运行前后的诊断结果。所选择的研究方向是相关的,因为它不仅允许人们预测防冻液在其运行过程中性能的变化,而且还可以获得金属腐蚀过程的证据。本研究的目的是对内燃机运行前后的防冻液进行控制试验,以确保动力单元处于良好状态。研究对象为新鲜AGA z -40- g12++防冻液(2021年发布;A-21)和冷却剂AGA Z-40-G12+(2012年发布;AE-12)运行数年后。结果表明,冷却液运行前后样品的pH值、密度、粘度、电导率均有差异。结果表明,A-21和AE-12的电导率随温度变化的过程是相同的。对t的依赖用多项式(二次)模型来描述。研究表明,AE-12氢指数较高可能表明金属在与防冻液接触过程中发生了电化学腐蚀,形成了短路的电偶。通过完全析因实验,证明了使用过的防冻液的较高pH值可以反映单乙二醇性能的降解和正在进行的金属腐蚀过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Analysis of antifreeze properties before and after their operation in engine
The results of diagnostics of antifreeze indicators before and after their operation in an internal combustion engine are presented. The chosen direction of research is relevant, since it allows one to predict not only the change in the properties of antifreeze during its operation, but also to obtain evidence of the course of metal corrosion processes. The purpose of the study - to conduct control tests of antifreezes before and after their operation in an internal combustion engine, that ensures the maintenance of the power unit in good condition. The objects of study were fresh AGA Z-40-G12++ antifreeze (release of 2021; A-21) and coolant AGA Z-40-G12+ (release of 2012; AE-12) after its operation for several years. It is shown that the pH, density, viscosity, electrical conductivity of the coolant samples before and after its operation are different. It was found that the course of the dependences of electrical conductivity on temperature t for samples A-21 and AE-12 is the same. The dependence of on t is described by a polynomial (quadratic) model. It has been suggested that higher values of the AE-12 hydrogen index may indicate the occurrence of electrochemical corrosion of metals, which, in the process of contact with antifreeze, form short-circuited galvanic pairs. With the help of a complete factorial experiment, it was demonstrated that higher pH values of used antifreeze can be a reflection of the degradation of the properties of monoethylene glycol and the ongoing processes of metal corrosion.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
期刊最新文献
General planetary vehicle and industrial space necklace “Orbit” as an alternative to rocket near space exploration Analysis of antifreeze properties before and after their operation in engine Hydrodynamic surfaces with midsection in the form of Lame curve On the way to autonomous navigation Development of a composite structure for biomechanical purposes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1