{"title":"压力中心测量误差与A/D转换器量化关系的量化","authors":"J. Koltermann, M. Gerber","doi":"10.3390/biomechanics2020024","DOIUrl":null,"url":null,"abstract":"In this scientific study, the question of the influence of the quantization error on the CoP measurement is be clarified. For this purpose, the quantization error is investigated in two scenarios, first with the technical/physical reproduction of the CoP, and then with test persons. From the results, a model is derived with which a technical and economic optimum between resolution and error can be generated for an individual case. The study was carried out with 170 healthy volunteers, aged 20–30 years. The test persons stood in a bipedal position for 15 s on a Kislter force plate (type 9260AA). In the investigation, it was shown that, for the measurement of center of pressure (CoP), signals to mostly 16-bit analog/digital converters are suitable but not, per se, the most economical variant. With the introduction of a quality criterion, a reasonable design for the planned test case can be made.","PeriodicalId":72381,"journal":{"name":"Biomechanics (Basel, Switzerland)","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantification of the Dependence of the Measurement Error on the Quantization of the A/D Converter for Center of Pressure Measurements\",\"authors\":\"J. Koltermann, M. Gerber\",\"doi\":\"10.3390/biomechanics2020024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this scientific study, the question of the influence of the quantization error on the CoP measurement is be clarified. For this purpose, the quantization error is investigated in two scenarios, first with the technical/physical reproduction of the CoP, and then with test persons. From the results, a model is derived with which a technical and economic optimum between resolution and error can be generated for an individual case. The study was carried out with 170 healthy volunteers, aged 20–30 years. The test persons stood in a bipedal position for 15 s on a Kislter force plate (type 9260AA). In the investigation, it was shown that, for the measurement of center of pressure (CoP), signals to mostly 16-bit analog/digital converters are suitable but not, per se, the most economical variant. With the introduction of a quality criterion, a reasonable design for the planned test case can be made.\",\"PeriodicalId\":72381,\"journal\":{\"name\":\"Biomechanics (Basel, Switzerland)\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomechanics (Basel, Switzerland)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/biomechanics2020024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomechanics (Basel, Switzerland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/biomechanics2020024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Quantification of the Dependence of the Measurement Error on the Quantization of the A/D Converter for Center of Pressure Measurements
In this scientific study, the question of the influence of the quantization error on the CoP measurement is be clarified. For this purpose, the quantization error is investigated in two scenarios, first with the technical/physical reproduction of the CoP, and then with test persons. From the results, a model is derived with which a technical and economic optimum between resolution and error can be generated for an individual case. The study was carried out with 170 healthy volunteers, aged 20–30 years. The test persons stood in a bipedal position for 15 s on a Kislter force plate (type 9260AA). In the investigation, it was shown that, for the measurement of center of pressure (CoP), signals to mostly 16-bit analog/digital converters are suitable but not, per se, the most economical variant. With the introduction of a quality criterion, a reasonable design for the planned test case can be made.