M. Khansari, Sara Shahreza, A. Rezvanirad, Amin Nikavar, Shahrzad Bikloo, B. Yousefsani
{"title":"哌甲酯表面分子印迹聚合物的合成及其在哌甲酯分离中的应用","authors":"M. Khansari, Sara Shahreza, A. Rezvanirad, Amin Nikavar, Shahrzad Bikloo, B. Yousefsani","doi":"10.4172/2155-9872.1000351","DOIUrl":null,"url":null,"abstract":"In this study, a novel approach is proposed for determination of methylphenidate in biological fluids. In this method molecularly imprinted solid-phase extraction (MISPE), as the sample extraction technique, combined with high-performance liquid chromatography (HPLC) is used. The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, Hexane as porogen and methylphenidate as template molecule. Extraction of methylphenidate from human serum was carried out using a novel imprinted polymer as the solid-phase extraction (SPE). Various parameters affecting the extraction efficiency of the polymer were evaluated. Also, the optimal conditions for the MIP cartridges were studied. The limit of detection (LOD) and limit of quantification (LOQ) for methylphenidate in serum samples were 1.3 and 10 ng mL-1, respectively. The recoveries for serum samples were higher than 92%.","PeriodicalId":14865,"journal":{"name":"Journal of analytical and bioanalytical techniques","volume":"31 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2017-02-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Synthesis of Surface Molecularly Imprinting Polymers for Methylphenidate andits Application in Separating Methylphenidate\",\"authors\":\"M. Khansari, Sara Shahreza, A. Rezvanirad, Amin Nikavar, Shahrzad Bikloo, B. Yousefsani\",\"doi\":\"10.4172/2155-9872.1000351\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this study, a novel approach is proposed for determination of methylphenidate in biological fluids. In this method molecularly imprinted solid-phase extraction (MISPE), as the sample extraction technique, combined with high-performance liquid chromatography (HPLC) is used. The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, Hexane as porogen and methylphenidate as template molecule. Extraction of methylphenidate from human serum was carried out using a novel imprinted polymer as the solid-phase extraction (SPE). Various parameters affecting the extraction efficiency of the polymer were evaluated. Also, the optimal conditions for the MIP cartridges were studied. The limit of detection (LOD) and limit of quantification (LOQ) for methylphenidate in serum samples were 1.3 and 10 ng mL-1, respectively. The recoveries for serum samples were higher than 92%.\",\"PeriodicalId\":14865,\"journal\":{\"name\":\"Journal of analytical and bioanalytical techniques\",\"volume\":\"31 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-02-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of analytical and bioanalytical techniques\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4172/2155-9872.1000351\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of analytical and bioanalytical techniques","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4172/2155-9872.1000351","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
本研究提出了一种测定生物体液中哌甲酯含量的新方法。该方法采用分子印迹固相萃取(MISPE)作为样品提取技术,结合高效液相色谱(HPLC)。以甲基丙烯酸为功能单体,乙二醇二甲基丙烯酸酯为交联剂,己烷为多孔剂,哌醋甲酯为模板分子,制备了水相容性分子印迹聚合物(MIPs)。采用新型印迹聚合物固相萃取(SPE)技术从人血清中提取哌甲酯。考察了影响聚合物萃取效率的各种参数。同时,研究了MIP筒的最佳工艺条件。血清样品中哌甲酯的检出限(LOD)和定量限(LOQ)分别为1.3和10 ng mL-1。血清样品加样回收率大于92%。
Synthesis of Surface Molecularly Imprinting Polymers for Methylphenidate andits Application in Separating Methylphenidate
In this study, a novel approach is proposed for determination of methylphenidate in biological fluids. In this method molecularly imprinted solid-phase extraction (MISPE), as the sample extraction technique, combined with high-performance liquid chromatography (HPLC) is used. The water-compatible molecularly imprinted polymers (MIPs) were prepared using methacrylic acid as functional monomer, ethylene glycol dimethacrylate as cross-linker, Hexane as porogen and methylphenidate as template molecule. Extraction of methylphenidate from human serum was carried out using a novel imprinted polymer as the solid-phase extraction (SPE). Various parameters affecting the extraction efficiency of the polymer were evaluated. Also, the optimal conditions for the MIP cartridges were studied. The limit of detection (LOD) and limit of quantification (LOQ) for methylphenidate in serum samples were 1.3 and 10 ng mL-1, respectively. The recoveries for serum samples were higher than 92%.