Q4 Medicine Duzce Medical Journal Pub Date : 2023-08-02 DOI:10.47493/abantmedj.1209807
Gurkan Yurteri̇, Sibel Ada
{"title":"Hemoliz Nedeni Olarak Diyalizörler","authors":"Gurkan Yurteri̇, Sibel Ada","doi":"10.47493/abantmedj.1209807","DOIUrl":null,"url":null,"abstract":"Objective: Hemolysis is a rare adverse effect of hemodialysis. ıt is induced by chemical pollution, heat, or mechanical harm to clogged hemodialysis lines. Lactate dehydrogenase transforms pyruvate to lactate in the absence of oxygen to make energy. LDH serum levels are raised due to tissue breakdown. A number of clinical illnesses, such as hemolytic disorders, are associated with high serum LDH. \nBoth the Rexeed and Leoceed dialyzers are made by AsahiKASEI. They had the same membrane architecture and permeability, but blood entry angle, chamber length, and hole count varied. The aim of this study is to examine if dialyzer design affects hemolysis. \nMaterials and Methods: A total of 142 patients who were chronically undergoing hemodialysis therapy at the ……………….for a total of 12 hours per week were included. A retrospective examination of the patients was performed. The pre-HD and post-HD LDH levels of individuals who had undergone hemodialysis with both dialyzers during separate sessions of hemodialysis were compared. \nResults: A hundred forty two patients (63% female) on hemodialysis (HD) treatment were enrolled in the study. Twenty eight patients (20%) had diabetes, 45 had hypertension (32%) and 16 had ischemic heart disease (11%) as a comorbid condition. \nWhen LDH difference is compared between groups Leoceed dialyzer group) had statistically significantly higher LDH difference when compared with Rexeed dialyzer group (49.1±20 U/l vs229.8±24.45 U/l;p=0.008). (Table 2). \nConclusion: It is possible that the design of the dialyzer contributes in some way to the cell damage that is caused by the larger serum LDH increase in the Leoceed dialyzer. In order to carry out corrective studies on dialyzer design, it would be helpful to analyze the impact of dialyzer design on cell damage using a larger series of patients.","PeriodicalId":53622,"journal":{"name":"Duzce Medical Journal","volume":"51 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-08-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Duzce Medical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.47493/abantmedj.1209807","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:溶血是一种罕见的血液透析不良反应。ıt是由化学污染、热或对堵塞的血液透析管道的机械损伤引起的。乳酸脱氢酶在缺氧的情况下将丙酮酸转化为乳酸以产生能量。乳酸脱氢酶血清水平升高是由于组织破坏。许多临床疾病,如溶血性疾病,与高血清乳酸脱氢酶有关。Rexeed和leoced透析器都是由旭化成制造的。它们具有相同的膜结构和通透性,但血液进入角度、腔室长度和孔数不同。本研究的目的是检验透析器设计是否影响溶血。材料与方法:在...................接受慢性血液透析治疗的142例患者每周总共12个小时。对患者进行回顾性检查。在单独的血液透析期间,比较使用两种透析器进行血液透析的个体的hd前和hd后LDH水平。结果:142例接受血液透析(HD)治疗的患者(63%为女性)被纳入研究。28名患者(20%)患有糖尿病,45名患有高血压(32%),16名患有缺血性心脏病(11%)作为合并症。当组间LDH差异比较时,Leoceed透析器组与Rexeed透析器组LDH差异有统计学意义(49.1±20 U/l vs229.8±24.45 U/l, p=0.008)。(表2)结论:Leoceed透析器中较高的血清LDH升高可能导致细胞损伤,透析器的设计在某种程度上可能起了作用。为了对透析器设计进行纠正性研究,利用更大的患者序列分析透析器设计对细胞损伤的影响是有帮助的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Hemoliz Nedeni Olarak Diyalizörler
Objective: Hemolysis is a rare adverse effect of hemodialysis. ıt is induced by chemical pollution, heat, or mechanical harm to clogged hemodialysis lines. Lactate dehydrogenase transforms pyruvate to lactate in the absence of oxygen to make energy. LDH serum levels are raised due to tissue breakdown. A number of clinical illnesses, such as hemolytic disorders, are associated with high serum LDH. Both the Rexeed and Leoceed dialyzers are made by AsahiKASEI. They had the same membrane architecture and permeability, but blood entry angle, chamber length, and hole count varied. The aim of this study is to examine if dialyzer design affects hemolysis. Materials and Methods: A total of 142 patients who were chronically undergoing hemodialysis therapy at the ……………….for a total of 12 hours per week were included. A retrospective examination of the patients was performed. The pre-HD and post-HD LDH levels of individuals who had undergone hemodialysis with both dialyzers during separate sessions of hemodialysis were compared. Results: A hundred forty two patients (63% female) on hemodialysis (HD) treatment were enrolled in the study. Twenty eight patients (20%) had diabetes, 45 had hypertension (32%) and 16 had ischemic heart disease (11%) as a comorbid condition. When LDH difference is compared between groups Leoceed dialyzer group) had statistically significantly higher LDH difference when compared with Rexeed dialyzer group (49.1±20 U/l vs229.8±24.45 U/l;p=0.008). (Table 2). Conclusion: It is possible that the design of the dialyzer contributes in some way to the cell damage that is caused by the larger serum LDH increase in the Leoceed dialyzer. In order to carry out corrective studies on dialyzer design, it would be helpful to analyze the impact of dialyzer design on cell damage using a larger series of patients.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Duzce Medical Journal
Duzce Medical Journal Medicine-Medicine (all)
CiteScore
0.60
自引率
0.00%
发文量
59
审稿时长
12 weeks
期刊最新文献
Karotis Stenozu Tedavisinde Karotis Arter Stentleme ve Karotis Endarterektomi Yöntemlerinin Kısa Dönem Sonuçları: Randomize Kontrollü Çalışmaların Güncel Bir Meta-Analizi The Effect of Treatment on Weight Gain in Iron Deficiency Anemia and Its Association with Ghrelin and Hepcidin Levels The Effect of Inflammatory Markers in the Hemogram Parameters of Pregnant Women with Thyroid Disease on Obstetric and Neonatal Outcomes A Rare Manifestation of Leptospirosis: Long-Term Elevation in Liver Enzymes Muscarinic Receptors as Targets for Metronomic Therapy in Ovarian Cancer
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1