{"title":"理想森林火灾情景下点状粒子最大距离的计算","authors":"J. Pereira, J. Pereira, André L. A. Leite, Duarte M. S. Albuquerque","doi":"10.1155/2015/513576","DOIUrl":null,"url":null,"abstract":"Large eddy simulation of the wind surface layer above and within vegetation was conducted in the presence of an idealised forest fire by using an equivalent volumetric heat source. Firebrand’s particles are represented as spherical particles with a wide range of sizes, which were located into the combustion volume in a random fashion and are convected in the ascending plume as Lagrangian points. The thermally thin particles undergo drag relative to the flow and moisture loss as they are dried and pyrolysis, char-combustion, and mass loss as they burn. The particle momentum, heat and mass transfer, and combustion governing equations were computed along particle trajectories in the unsteady 3D wind field until their deposition on the ground. The spotting distances are compared with the maximum spotting distance obtained with Albini model for several idealised line grass or torching trees fires scenarios. The prediction of the particle maximum spotting distance for a 2000 kW/m short grass fire compared satisfactorily with results from Albini model and underpredicted by 40% the results for a high intensity 50000 kW/m fire. For the cases of single and four torching trees the model predicts the maximum distances consistently but for slightly different particle diameter.","PeriodicalId":44364,"journal":{"name":"Journal of Combustion","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2015-06-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Calculation of Spotting Particles Maximum Distance in Idealised Forest Fire Scenarios\",\"authors\":\"J. Pereira, J. Pereira, André L. A. Leite, Duarte M. S. Albuquerque\",\"doi\":\"10.1155/2015/513576\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Large eddy simulation of the wind surface layer above and within vegetation was conducted in the presence of an idealised forest fire by using an equivalent volumetric heat source. Firebrand’s particles are represented as spherical particles with a wide range of sizes, which were located into the combustion volume in a random fashion and are convected in the ascending plume as Lagrangian points. The thermally thin particles undergo drag relative to the flow and moisture loss as they are dried and pyrolysis, char-combustion, and mass loss as they burn. The particle momentum, heat and mass transfer, and combustion governing equations were computed along particle trajectories in the unsteady 3D wind field until their deposition on the ground. The spotting distances are compared with the maximum spotting distance obtained with Albini model for several idealised line grass or torching trees fires scenarios. The prediction of the particle maximum spotting distance for a 2000 kW/m short grass fire compared satisfactorily with results from Albini model and underpredicted by 40% the results for a high intensity 50000 kW/m fire. For the cases of single and four torching trees the model predicts the maximum distances consistently but for slightly different particle diameter.\",\"PeriodicalId\":44364,\"journal\":{\"name\":\"Journal of Combustion\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2015-06-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Combustion\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2015/513576\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, CHEMICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Combustion","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2015/513576","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CHEMICAL","Score":null,"Total":0}
引用次数: 10

摘要

利用等效体积热源,在理想森林火灾条件下,对植被上方和植被内部的风面层进行了大涡模拟。Firebrand的颗粒被表示为球形颗粒,其大小范围很宽,以随机方式分布在燃烧体中,并以拉格朗日点的形式在上升羽流中对流。在干燥、热解、炭燃烧和燃烧过程中,热薄颗粒受到相对于流动和水分损失的阻力。在非定常三维风场中沿粒子轨迹计算粒子动量、传热传质和燃烧控制方程,直至粒子沉降到地面。将该点状距离与Albini模型在几种理想的线草或火把树火灾情景下获得的最大点状距离进行了比较。2000 kW/m短草火灾的颗粒最大点状距离预测结果与Albini模型的结果比较满意,比50000 kW/m高强度火灾的预测结果低40%。对于单棵和四棵燃烧树的情况,模型预测的最大距离一致,但颗粒直径略有不同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Calculation of Spotting Particles Maximum Distance in Idealised Forest Fire Scenarios
Large eddy simulation of the wind surface layer above and within vegetation was conducted in the presence of an idealised forest fire by using an equivalent volumetric heat source. Firebrand’s particles are represented as spherical particles with a wide range of sizes, which were located into the combustion volume in a random fashion and are convected in the ascending plume as Lagrangian points. The thermally thin particles undergo drag relative to the flow and moisture loss as they are dried and pyrolysis, char-combustion, and mass loss as they burn. The particle momentum, heat and mass transfer, and combustion governing equations were computed along particle trajectories in the unsteady 3D wind field until their deposition on the ground. The spotting distances are compared with the maximum spotting distance obtained with Albini model for several idealised line grass or torching trees fires scenarios. The prediction of the particle maximum spotting distance for a 2000 kW/m short grass fire compared satisfactorily with results from Albini model and underpredicted by 40% the results for a high intensity 50000 kW/m fire. For the cases of single and four torching trees the model predicts the maximum distances consistently but for slightly different particle diameter.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Combustion
Journal of Combustion ENGINEERING, CHEMICAL-
CiteScore
2.00
自引率
28.60%
发文量
8
审稿时长
20 weeks
期刊最新文献
Design, Modeling, and Feasibility Analysis of Rotary Valve for Internal Combustion Engine Comparative Analysis of Swirl Burner and Cross Jet Burner in Terms of Efficiency and Environmental Performance Uranium Dust Cloud Combustion: Burning Characteristics and Absorption Spectroscopy Measurements An Overview of Energy Recovery from Local Slaughterhouse-Based Gallus gallus domesticus Greasy Residues and Latest Applications Effectiveness of Charcoal Adsorbent in Flue Gas Filters for PCB Reduction in Smoke from Hospital Incinerators
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1