{"title":"并网逆变器中基于电流反馈的混合共模EMI滤波器","authors":"Ming Li, M. Shen, Lei Xing, W. Said","doi":"10.1109/ECCE.2012.6342652","DOIUrl":null,"url":null,"abstract":"In this paper, a current feedback based hybrid common-mode EMI filter is presented for grid-tied inverter application, which employs passive filter with parallel damping branch. A current transformer is used to sense the target common-mode (CM) current, and the active circuit injects cancelation CM current via coupling capacitor. In particular, the proposed hybrid EMI filter with 2nd order high pass filter characteristic equivalently enhances the filter capacitance at high frequency range. Standalone and offline experimental results based on grid tied three-phase inverter system show that the proposed hybrid filter can improve the EMI attenuation by 10~20 dB beyond 150 kHz.","PeriodicalId":6401,"journal":{"name":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2012-11-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Current feedback based hybrid common-mode EMI filter for grid-tied inverter application\",\"authors\":\"Ming Li, M. Shen, Lei Xing, W. Said\",\"doi\":\"10.1109/ECCE.2012.6342652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper, a current feedback based hybrid common-mode EMI filter is presented for grid-tied inverter application, which employs passive filter with parallel damping branch. A current transformer is used to sense the target common-mode (CM) current, and the active circuit injects cancelation CM current via coupling capacitor. In particular, the proposed hybrid EMI filter with 2nd order high pass filter characteristic equivalently enhances the filter capacitance at high frequency range. Standalone and offline experimental results based on grid tied three-phase inverter system show that the proposed hybrid filter can improve the EMI attenuation by 10~20 dB beyond 150 kHz.\",\"PeriodicalId\":6401,\"journal\":{\"name\":\"2012 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE.2012.6342652\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2012.6342652","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

本文提出了一种基于电流反馈的并网逆变器混合共模电磁干扰滤波器,该滤波器采用带并联阻尼支路的无源滤波器。电流互感器用于检测目标共模电流,有源电路通过耦合电容注入抵消共模电流。特别地,所提出的具有二阶高通滤波器特性的混合式EMI滤波器在高频范围内等效地提高了滤波器的电容。基于并网三相逆变器系统的单机和离线实验结果表明,所提出的混合滤波器在150 kHz范围内可使电磁干扰衰减提高10~20 dB。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Current feedback based hybrid common-mode EMI filter for grid-tied inverter application
In this paper, a current feedback based hybrid common-mode EMI filter is presented for grid-tied inverter application, which employs passive filter with parallel damping branch. A current transformer is used to sense the target common-mode (CM) current, and the active circuit injects cancelation CM current via coupling capacitor. In particular, the proposed hybrid EMI filter with 2nd order high pass filter characteristic equivalently enhances the filter capacitance at high frequency range. Standalone and offline experimental results based on grid tied three-phase inverter system show that the proposed hybrid filter can improve the EMI attenuation by 10~20 dB beyond 150 kHz.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Alternative excitation strategies for a wound rotor synchronous machine drive Design of LCL filters in consideration of parameter variations for grid-connected converters Design, modelling and testing of a high speed induction machine drive A modified Boost topology with simultaneous AC and DC load Optimal zero-vector configuration for space vector modulated AC-DC matrix converter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1