{"title":"半自动化全自动血清电泳仪实现过程中与手工相相关的解释问题","authors":"R. Karfo, Elie Kabr e, Nadia Safir, Mounya Bouabdellah, Laila Benchekroun, Jean Sakand e, L. Chabraoui","doi":"10.5897/AJBR2018.1017","DOIUrl":null,"url":null,"abstract":"Manual steps including preparation of samples and gel, and launching of automatic sequences can cause many difficulties in the interpretation of electrophoresis. Three observations of electrophoretic profiles on Hydragel 15β1-β2 agarose gel media led us to look for interference in the manual step of the technique used. After reconsidering all the steps of the manipulation and carefully observing the profiles obtained on the three plates of the agarose gel, the management of the deposition of the filter paper was identified as the cause in the first observation. The holding of the gel plate and the insufficient deposition of serum were identified as the main causes in the second observation. Mismanagement of the plate was identified as the cause in the third observation. All of these assumptions were confirmed by tests done on the bench. These observations remind us of the importance of the manual phase with semi-automatic devices for obtaining reliable results and for easy interpretation of  results. \n \n   \n \n Key words: Electrophoresis, migration, albumin, gamma, densitometer.","PeriodicalId":7631,"journal":{"name":"African Journal of Biochemistry Research","volume":"67 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-04-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Problems of interpretation of serum electrophoresis related to the manual phase during its realization with a semi-automatic automaton\",\"authors\":\"R. Karfo, Elie Kabr e, Nadia Safir, Mounya Bouabdellah, Laila Benchekroun, Jean Sakand e, L. Chabraoui\",\"doi\":\"10.5897/AJBR2018.1017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Manual steps including preparation of samples and gel, and launching of automatic sequences can cause many difficulties in the interpretation of electrophoresis. Three observations of electrophoretic profiles on Hydragel 15β1-β2 agarose gel media led us to look for interference in the manual step of the technique used. After reconsidering all the steps of the manipulation and carefully observing the profiles obtained on the three plates of the agarose gel, the management of the deposition of the filter paper was identified as the cause in the first observation. The holding of the gel plate and the insufficient deposition of serum were identified as the main causes in the second observation. Mismanagement of the plate was identified as the cause in the third observation. All of these assumptions were confirmed by tests done on the bench. These observations remind us of the importance of the manual phase with semi-automatic devices for obtaining reliable results and for easy interpretation of  results. \\n \\n   \\n \\n Key words: Electrophoresis, migration, albumin, gamma, densitometer.\",\"PeriodicalId\":7631,\"journal\":{\"name\":\"African Journal of Biochemistry Research\",\"volume\":\"67 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-04-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"African Journal of Biochemistry Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5897/AJBR2018.1017\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"African Journal of Biochemistry Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5897/AJBR2018.1017","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

手工步骤包括样品和凝胶的制备,以及启动自动序列会在电泳解释中造成许多困难。我们对Hydragel 15β1-β2琼脂糖凝胶介质的电泳图谱进行了三次观察,以寻找所使用技术手动步骤中的干扰。在重新考虑了操作的所有步骤并仔细观察了琼脂糖凝胶的三个板上获得的轮廓后,在第一次观察中确定了滤纸沉积的管理是原因。在第二次观察中,凝胶板的握住和血清沉积不足被确定为主要原因。在第三次观察中,钢板管理不善被确定为原因。所有这些假设都得到了台架试验的证实。这些观察结果提醒我们,手动阶段与半自动装置对于获得可靠的结果和易于解释结果的重要性。关键词:电泳,迁移,白蛋白,γ,密度计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Problems of interpretation of serum electrophoresis related to the manual phase during its realization with a semi-automatic automaton
Manual steps including preparation of samples and gel, and launching of automatic sequences can cause many difficulties in the interpretation of electrophoresis. Three observations of electrophoretic profiles on Hydragel 15β1-β2 agarose gel media led us to look for interference in the manual step of the technique used. After reconsidering all the steps of the manipulation and carefully observing the profiles obtained on the three plates of the agarose gel, the management of the deposition of the filter paper was identified as the cause in the first observation. The holding of the gel plate and the insufficient deposition of serum were identified as the main causes in the second observation. Mismanagement of the plate was identified as the cause in the third observation. All of these assumptions were confirmed by tests done on the bench. These observations remind us of the importance of the manual phase with semi-automatic devices for obtaining reliable results and for easy interpretation of  results.   Key words: Electrophoresis, migration, albumin, gamma, densitometer.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Effect of conditions in the production of highly soluble powder from tomatoes using microbial enzyme preparation Physicochemical properties and fatty acid composition of freshly prepared palm oil Physicochemical parameters of Blighia sapida (K.D. Koenig) oil extracted in Togo Effects of Quantitative Trait Loci (QTLs) of BCL11A and HBS1L-MYB genes on clinical-biological variability of sickle cell disease in a Senegalese pediatric population Investigation into the intake of a popular polyherbal drug (Jalin Herbal Mannex Liquid) on selected biochemical indices of male wister rats
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1