综合分析了当使用直流链路扼流圈与输入线路电抗器时的驱动性能

Alia R. Strandt, R. Tallam
{"title":"综合分析了当使用直流链路扼流圈与输入线路电抗器时的驱动性能","authors":"Alia R. Strandt, R. Tallam","doi":"10.1109/ECCE.2015.7310063","DOIUrl":null,"url":null,"abstract":"Differences between a dc link choke versus an input line reactor in an adjustable speed drive can be examined based on several different aspects of drive performance, including harmonic mitigation, dc bus voltage drop, operation during voltage imbalance, cost of the reactor, electric surge protection, and operation for different types of system grounding. Of these performance aspects, harmonic mitigation, bus voltage drop, operation during voltage imbalance, and cost are well understood in prior art. In this paper, the effectiveness of dc link chokes and input line reactors for both surge protection and common mode (CM) issues on different types of system grounding is examined. The harmonic performance of each reactor type as well as the relative dc bus voltage drop are also reviewed for completeness.","PeriodicalId":6654,"journal":{"name":"2015 IEEE Energy Conversion Congress and Exposition (ECCE)","volume":"1 1","pages":"2876-2883"},"PeriodicalIF":0.0000,"publicationDate":"2015-10-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Comprehensive analysis of drive performance when using a dc link choke vs. an input line reactor\",\"authors\":\"Alia R. Strandt, R. Tallam\",\"doi\":\"10.1109/ECCE.2015.7310063\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Differences between a dc link choke versus an input line reactor in an adjustable speed drive can be examined based on several different aspects of drive performance, including harmonic mitigation, dc bus voltage drop, operation during voltage imbalance, cost of the reactor, electric surge protection, and operation for different types of system grounding. Of these performance aspects, harmonic mitigation, bus voltage drop, operation during voltage imbalance, and cost are well understood in prior art. In this paper, the effectiveness of dc link chokes and input line reactors for both surge protection and common mode (CM) issues on different types of system grounding is examined. The harmonic performance of each reactor type as well as the relative dc bus voltage drop are also reviewed for completeness.\",\"PeriodicalId\":6654,\"journal\":{\"name\":\"2015 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"volume\":\"1 1\",\"pages\":\"2876-2883\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-10-29\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 IEEE Energy Conversion Congress and Exposition (ECCE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECCE.2015.7310063\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 IEEE Energy Conversion Congress and Exposition (ECCE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECCE.2015.7310063","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

直流链路扼流圈与输入线路电抗器在可调速驱动器中的差异可以根据驱动器性能的几个不同方面进行检查,包括谐波缓解、直流母线压降、电压不平衡期间的运行、电抗器成本、电涌保护和不同类型系统接地的运行。在这些性能方面,谐波缓解、母线电压降、电压不平衡期间的操作和成本在现有技术中得到了很好的理解。本文研究了直流链路扼流圈和输入线路电抗器对不同类型系统接地的浪涌保护和共模问题的有效性。为了完整起见,还对各种电抗器的谐波性能以及直流母线的相对电压降进行了综述。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Comprehensive analysis of drive performance when using a dc link choke vs. an input line reactor
Differences between a dc link choke versus an input line reactor in an adjustable speed drive can be examined based on several different aspects of drive performance, including harmonic mitigation, dc bus voltage drop, operation during voltage imbalance, cost of the reactor, electric surge protection, and operation for different types of system grounding. Of these performance aspects, harmonic mitigation, bus voltage drop, operation during voltage imbalance, and cost are well understood in prior art. In this paper, the effectiveness of dc link chokes and input line reactors for both surge protection and common mode (CM) issues on different types of system grounding is examined. The harmonic performance of each reactor type as well as the relative dc bus voltage drop are also reviewed for completeness.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Accuracy comparison between Gompertz and polynomial based PV models Grid synchronization for a virtual direct power-controlled DFIG wind power system Enhancement on capacitor-voltage-balancing capability of a modular multilevel cascade inverter for medium-voltage synchronous-motor drives State observer for sensorless control of a grid-connected converter equipped with an LCL filter: Direct discrete-time design Multi-tap transformer topologies for improved tolerance against misalignment in inductive power transfer systems for electric vehicles
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1