Failure of pacemaker electrode leads.

European journal of cardiology Pub Date : 1979-11-01
T K Kaul, G D Green, W H Bain
{"title":"Failure of pacemaker electrode leads.","authors":"T K Kaul,&nbsp;G D Green,&nbsp;W H Bain","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>With the application of new power sources to pacemakers, considerable improvement has been achieved in the theoretical implant lifetime of current pulse generators, and equally reliable electrode leads will be necessary to ensure long-term pacing. The durability of the electrodes implanted in the past ten years in this centre has been carefully studied. The findings suggest that the use of a more durable conductor material and development of the concept of a 'fail safe' lead (using multi-filament conductors or a secondary conductive pathway along the electrode) will be necessary to match with the implant lifetime of the newer pulse generators. The diagnosis and management of broken conductors is discussed.</p>","PeriodicalId":72971,"journal":{"name":"European journal of cardiology","volume":"10 5","pages":"385-94"},"PeriodicalIF":0.0000,"publicationDate":"1979-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of cardiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

With the application of new power sources to pacemakers, considerable improvement has been achieved in the theoretical implant lifetime of current pulse generators, and equally reliable electrode leads will be necessary to ensure long-term pacing. The durability of the electrodes implanted in the past ten years in this centre has been carefully studied. The findings suggest that the use of a more durable conductor material and development of the concept of a 'fail safe' lead (using multi-filament conductors or a secondary conductive pathway along the electrode) will be necessary to match with the implant lifetime of the newer pulse generators. The diagnosis and management of broken conductors is discussed.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
起搏器电极导线失效。
随着新型电源在起搏器中的应用,电流脉冲发生器的理论植入寿命得到了相当大的改善,同样可靠的电极引线将是确保长期起搏的必要条件。在过去的十年里,该中心对植入的电极的耐久性进行了仔细的研究。研究结果表明,使用更耐用的导体材料和开发“故障安全”引线的概念(使用多丝导体或沿电极的二次导电路径)将与新型脉冲发生器的植入寿命相匹配。对导线断裂的诊断和处理进行了探讨。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Plasma pancreatic polypeptide and gastrin in the assessment of autonomic activity in acute myocardial infarction. Effects of intrinsic sympathetic activity of beta-blockers on SA and AV nodes in man. Coronary arterial stenosis and subclavian steal in Takayasu's arteritis. Changes in 86-rubidium uptake in erythrocytes of digoxin-treated patients, in heart failure with sinus rhythm. Relationship to clinical effects. Digoxin in the elderly and in renal failure. Contribution of erythrocyte 86-rubidium uptake tests.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1