Ying Liu , Qingyun Ma , Zhixuan Wang , Xinxin Shang , Yuting Lan , Guoping Guan , Lu Wang
{"title":"Antimicrobial peptide-based pH-responsive Polyvinyl alcohol hydrogel artificial vascular grafts with excellent antimicrobial and hematologic compatibility","authors":"Ying Liu , Qingyun Ma , Zhixuan Wang , Xinxin Shang , Yuting Lan , Guoping Guan , Lu Wang","doi":"10.1016/j.eurpolymj.2024.113554","DOIUrl":null,"url":null,"abstract":"<div><div>Thrombosis and infection are the primary challenges limiting the clinical application of small-diameter artificial blood vessels. Numerous studies have focused on improving the hemocompatibility of artificial vascular materials, addressing properties such as anticoagulant activity, antithrombogenicity, low hemolysis rates, and reduced platelet adhesion. However, there has been comparatively less attention given to the antibacterial properties of these materials. This study utilizes polyester braided tubes and PVA/PAAm hydrogel materials, combined with surface modification techniques, to develop a pH-responsive antibacterial hydrogel artificial blood vessel graft. The hydrogel surface was grafted with a polymer brush hierarchical structure, and antimicrobial peptide MLT was immobilized to confer antibacterial properties. Additionally, 2,3-dimethylmaleic anhydride (DMMA) was covalently attached as a shielding group to achieve an environment-responsive strategy. The research demonstrates that this artificial blood vessel graft exhibits structural stability, excellent mechanical properties, and good cellular and hemocompatibility. Furthermore, it exhibits pH-responsive capabilities, triggering efficient antibacterial activity in low pH environments. The modified antibacterial hydrogel artificial blood vessel material shows low hemolysis rates, excellent anticoagulant properties, and reduced platelet adhesion. Therefore, the strategy of combining MLT with DMMA may effectively enhance the hemocompatibility and responsive antibacterial performance of artificial blood vessel materials.</div></div>","PeriodicalId":315,"journal":{"name":"European Polymer Journal","volume":"221 ","pages":"Article 113554"},"PeriodicalIF":5.8000,"publicationDate":"2024-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Polymer Journal","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0014305724008152","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"POLYMER SCIENCE","Score":null,"Total":0}
引用次数: 0
Abstract
Thrombosis and infection are the primary challenges limiting the clinical application of small-diameter artificial blood vessels. Numerous studies have focused on improving the hemocompatibility of artificial vascular materials, addressing properties such as anticoagulant activity, antithrombogenicity, low hemolysis rates, and reduced platelet adhesion. However, there has been comparatively less attention given to the antibacterial properties of these materials. This study utilizes polyester braided tubes and PVA/PAAm hydrogel materials, combined with surface modification techniques, to develop a pH-responsive antibacterial hydrogel artificial blood vessel graft. The hydrogel surface was grafted with a polymer brush hierarchical structure, and antimicrobial peptide MLT was immobilized to confer antibacterial properties. Additionally, 2,3-dimethylmaleic anhydride (DMMA) was covalently attached as a shielding group to achieve an environment-responsive strategy. The research demonstrates that this artificial blood vessel graft exhibits structural stability, excellent mechanical properties, and good cellular and hemocompatibility. Furthermore, it exhibits pH-responsive capabilities, triggering efficient antibacterial activity in low pH environments. The modified antibacterial hydrogel artificial blood vessel material shows low hemolysis rates, excellent anticoagulant properties, and reduced platelet adhesion. Therefore, the strategy of combining MLT with DMMA may effectively enhance the hemocompatibility and responsive antibacterial performance of artificial blood vessel materials.
期刊介绍:
European Polymer Journal is dedicated to publishing work on fundamental and applied polymer chemistry and macromolecular materials. The journal covers all aspects of polymer synthesis, including polymerization mechanisms and chemical functional transformations, with a focus on novel polymers and the relationships between molecular structure and polymer properties. In addition, we welcome submissions on bio-based or renewable polymers, stimuli-responsive systems and polymer bio-hybrids. European Polymer Journal also publishes research on the biomedical application of polymers, including drug delivery and regenerative medicine. The main scope is covered but not limited to the following core research areas:
Polymer synthesis and functionalization
• Novel synthetic routes for polymerization, functional modification, controlled/living polymerization and precision polymers.
Stimuli-responsive polymers
• Including shape memory and self-healing polymers.
Supramolecular polymers and self-assembly
• Molecular recognition and higher order polymer structures.
Renewable and sustainable polymers
• Bio-based, biodegradable and anti-microbial polymers and polymeric bio-nanocomposites.
Polymers at interfaces and surfaces
• Chemistry and engineering of surfaces with biological relevance, including patterning, antifouling polymers and polymers for membrane applications.
Biomedical applications and nanomedicine
• Polymers for regenerative medicine, drug delivery molecular release and gene therapy
The scope of European Polymer Journal no longer includes Polymer Physics.