MHAGuideNet: a 3D pre-trained guidance model for Alzheimer's Disease diagnosis using 2D multi-planar sMRI images.

IF 2.9 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING BMC Medical Imaging Pub Date : 2024-12-18 DOI:10.1186/s12880-024-01520-0
Yuanbi Nie, Qiushi Cui, Wenyuan Li, Yang Lü, Tianqing Deng
{"title":"MHAGuideNet: a 3D pre-trained guidance model for Alzheimer's Disease diagnosis using 2D multi-planar sMRI images.","authors":"Yuanbi Nie, Qiushi Cui, Wenyuan Li, Yang Lü, Tianqing Deng","doi":"10.1186/s12880-024-01520-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Alzheimer's Disease is a neurodegenerative condition leading to irreversible and progressive brain damage, with possible features such as structural atrophy. Effective precision diagnosis is crucial for slowing disease progression and reducing the incidence rate and morbidity. Traditional computer-aided diagnostic methods using structural MRI data often focus on capturing such features but face challenges, like overfitting with 3D image analysis and insufficient feature capture with 2D slices, potentially missing multi-planar information, and the complementary nature of features across different orientations.</p><p><strong>Methods: </strong>The study introduces MHAGuideNet, a classification method incorporating a guidance network utilizing multi-head attention. The model utilizes a pre-trained 3D convolutional neural network to direct the feature extraction of multi-planar 2D slices, specifically targeting the detection of features like structural atrophy. Additionally, a hybrid 2D slice-level network combining 2D CNN and 2D Swin Transformer is employed to capture the interrelations between the atrophy in different brain structures associated with Alzheimer's Disease.</p><p><strong>Results: </strong>The proposed MHAGuideNet is tested using two datasets: the ADNI and OASIS datasets. The model achieves an accuracy of 97.58%, specificity of 99.89%, F1 score of 93.98%, and AUC of 99.31% on the ADNI test dataset, demonstrating superior performance in distinguishing between Alzheimer's Disease and cognitively normal subjects. Furthermore, testing on the independent OASIA test dataset yields an accuracy of 96.02%, demonstrating the model's robust performance across different datasets.</p><p><strong>Conclusion: </strong>MHAGuideNet shows great promise as an effective tool for the computer-aided diagnosis of Alzheimer's Disease. Within the guidance of information from the 3D pre-trained CNN, the ability to leverage multi-planar information and capture subtle brain changes, including the interrelations between different structural atrophies, underscores its potential for clinical application.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"24 1","pages":"338"},"PeriodicalIF":2.9000,"publicationDate":"2024-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11656594/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-024-01520-0","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Alzheimer's Disease is a neurodegenerative condition leading to irreversible and progressive brain damage, with possible features such as structural atrophy. Effective precision diagnosis is crucial for slowing disease progression and reducing the incidence rate and morbidity. Traditional computer-aided diagnostic methods using structural MRI data often focus on capturing such features but face challenges, like overfitting with 3D image analysis and insufficient feature capture with 2D slices, potentially missing multi-planar information, and the complementary nature of features across different orientations.

Methods: The study introduces MHAGuideNet, a classification method incorporating a guidance network utilizing multi-head attention. The model utilizes a pre-trained 3D convolutional neural network to direct the feature extraction of multi-planar 2D slices, specifically targeting the detection of features like structural atrophy. Additionally, a hybrid 2D slice-level network combining 2D CNN and 2D Swin Transformer is employed to capture the interrelations between the atrophy in different brain structures associated with Alzheimer's Disease.

Results: The proposed MHAGuideNet is tested using two datasets: the ADNI and OASIS datasets. The model achieves an accuracy of 97.58%, specificity of 99.89%, F1 score of 93.98%, and AUC of 99.31% on the ADNI test dataset, demonstrating superior performance in distinguishing between Alzheimer's Disease and cognitively normal subjects. Furthermore, testing on the independent OASIA test dataset yields an accuracy of 96.02%, demonstrating the model's robust performance across different datasets.

Conclusion: MHAGuideNet shows great promise as an effective tool for the computer-aided diagnosis of Alzheimer's Disease. Within the guidance of information from the 3D pre-trained CNN, the ability to leverage multi-planar information and capture subtle brain changes, including the interrelations between different structural atrophies, underscores its potential for clinical application.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
求助全文
约1分钟内获得全文 去求助
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
期刊最新文献
High-risk habitat radiomics model based on ultrasound images for predicting lateral neck lymph node metastasis in differentiated thyroid cancer. Investigating resting-state functional connectivity changes within procedural memory network across neuropsychiatric disorders using fMRI. Optimizing hip MRI: enhancing image quality and elevating inter-observer consistency using deep learning-powered reconstruction. Comparison of diagnostic performance for pulmonary nodule detection between free-breathing spiral ultrashort echo time and free-breathing radial volumetric interpolated breath-hold examination. Knowledge discovery from database: MRI radiomic features to assess recurrence risk in high-grade meningiomas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1