{"title":"Low-activity [<sup>18</sup>F]-somatostatin receptor (SSTR) imaging using [<sup>18</sup>F]SiTATE on a long axial field-of-view PET/CT scanner.","authors":"Nils F Trautwein, Eduardo Calderón, Pia M Linder, Gerald Reischl, Philippe Driessen, Wenhong Lan, Andreas S Brendlin, Thorben Groß, Helmut Dittmann, Martina Hinterleitner, Christian la Fougère, Fabian P Schmidt, Lena S Kiefer","doi":"10.1186/s40658-025-00720-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong><sup>18</sup>F-labelled somatostatin receptor tracers have recently gained popularity due to their better spatial resolution, longer half-life and lower costs compared to <sup>68</sup>Ga-labeled tracers. The aim of this study was to evaluate the impact and limitations of reduced administered activities of [<sup>18</sup>F]SiTATE on image quality, lesion detectability and quantitative PET parameters in a long axial field-of-view (LAFOV) PET/CT scanner.</p><p><strong>Methods: </strong>Twenty-four patients with histologically confirmed neuroendocrine tumor, who underwent clinically indicated [<sup>18</sup>F]SiTATE PET/CT examination (3.0 MBq/kg, 5 min PET scan time) on a Siemens Biograph Vision Quadra LAFOV PET/CT, were included retrospectively in this study. PET list-mode data were rebinned for shorter frame durations to simulate 5 min scans with lower activities of injected radiotracer. A comparison of image reconstruction in high sensitivity (HS) and ultra-high sensitivity mode (UHS) mode was performed. Subjective image quality, noise and lesion detectability of n = 122 lesions were rated using a 5-point Likert scale. The molecular tumor volume (MTV), signal-to-noise ratio (SNR), tumor-to-liver activity concentration ratio (TLR) and standardized uptake values (SUV) were analyzed.</p><p><strong>Results: </strong>Subjective image quality decreased with simulated reduction of injected activity with generally superior ratings in the UHS mode compared to the HS mode. Despite a reduction to 1 MBq/kg of [<sup>18</sup>F]SiTATE all lesions were still detected while at 0.25 MBq/kg lesion detectability decreased to 70% (HS) and 93% (UHS). Only minor changes in SUV<sub>mean</sub> and TLR were detected with reduced activity. However, reduced activities led to an increase in SUV<sub>SD</sub>, which in turn caused a decrease in SNR (at 1 MBq/kg: 7.3 in HS and 9.0 in UHS mode and an increase in deviation of the MTV.</p><p><strong>Conclusion: </strong>Reducing the administered activity of injected [<sup>18</sup>F]SiTATE by 66% to 1 MBq/kg (HS & UHS) is feasible in a LAFOV PET/CT scanner, maintaining clinically diagnostic image quality without statistically significant deviations in PET uptake parameters and MTV. Furthermore, in low activity [<sup>18</sup>F]SiTATE PET/CT, the UHS mode improves image quality and noise as well as lesion detectability compared to HS mode, further reinforcing the clinical benefits of this recently introduced reconstruction mode.</p>","PeriodicalId":11559,"journal":{"name":"EJNMMI Physics","volume":"12 1","pages":"13"},"PeriodicalIF":3.0000,"publicationDate":"2025-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11799470/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"EJNMMI Physics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40658-025-00720-z","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: 18F-labelled somatostatin receptor tracers have recently gained popularity due to their better spatial resolution, longer half-life and lower costs compared to 68Ga-labeled tracers. The aim of this study was to evaluate the impact and limitations of reduced administered activities of [18F]SiTATE on image quality, lesion detectability and quantitative PET parameters in a long axial field-of-view (LAFOV) PET/CT scanner.

Methods: Twenty-four patients with histologically confirmed neuroendocrine tumor, who underwent clinically indicated [18F]SiTATE PET/CT examination (3.0 MBq/kg, 5 min PET scan time) on a Siemens Biograph Vision Quadra LAFOV PET/CT, were included retrospectively in this study. PET list-mode data were rebinned for shorter frame durations to simulate 5 min scans with lower activities of injected radiotracer. A comparison of image reconstruction in high sensitivity (HS) and ultra-high sensitivity mode (UHS) mode was performed. Subjective image quality, noise and lesion detectability of n = 122 lesions were rated using a 5-point Likert scale. The molecular tumor volume (MTV), signal-to-noise ratio (SNR), tumor-to-liver activity concentration ratio (TLR) and standardized uptake values (SUV) were analyzed.

Results: Subjective image quality decreased with simulated reduction of injected activity with generally superior ratings in the UHS mode compared to the HS mode. Despite a reduction to 1 MBq/kg of [18F]SiTATE all lesions were still detected while at 0.25 MBq/kg lesion detectability decreased to 70% (HS) and 93% (UHS). Only minor changes in SUVmean and TLR were detected with reduced activity. However, reduced activities led to an increase in SUVSD, which in turn caused a decrease in SNR (at 1 MBq/kg: 7.3 in HS and 9.0 in UHS mode and an increase in deviation of the MTV.

Conclusion: Reducing the administered activity of injected [18F]SiTATE by 66% to 1 MBq/kg (HS & UHS) is feasible in a LAFOV PET/CT scanner, maintaining clinically diagnostic image quality without statistically significant deviations in PET uptake parameters and MTV. Furthermore, in low activity [18F]SiTATE PET/CT, the UHS mode improves image quality and noise as well as lesion detectability compared to HS mode, further reinforcing the clinical benefits of this recently introduced reconstruction mode.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
在长轴视场 PET/CT 扫描仪上使用[18F]SiTATE 进行低活性[18F]-somatostatin 受体(SSTR)成像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
EJNMMI Physics
EJNMMI Physics Physics and Astronomy-Radiation
CiteScore
6.70
自引率
10.00%
发文量
78
审稿时长
13 weeks
期刊介绍: EJNMMI Physics is an international platform for scientists, users and adopters of nuclear medicine with a particular interest in physics matters. As a companion journal to the European Journal of Nuclear Medicine and Molecular Imaging, this journal has a multi-disciplinary approach and welcomes original materials and studies with a focus on applied physics and mathematics as well as imaging systems engineering and prototyping in nuclear medicine. This includes physics-driven approaches or algorithms supported by physics that foster early clinical adoption of nuclear medicine imaging and therapy.
期刊最新文献
ASICs in PET: what we have and what we need. A generative whole-brain segmentation model for positron emission tomography images. On the reduction of imaging time-points for dosimetry in radionuclide therapy. Discordance between 90Y-PET/CT(MR)-estimated activity and dose calibrator measured administered activity: an international study in SIRT patients treated with resin and glass microspheres. Low-activity [18F]-somatostatin receptor (SSTR) imaging using [18F]SiTATE on a long axial field-of-view PET/CT scanner.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1