Incomplete interpolation caused by sinoatrial pacemaker shift. A report of two cases.

European journal of cardiology Pub Date : 1980-01-01
F Franchi, L Padeletti
{"title":"Incomplete interpolation caused by sinoatrial pacemaker shift. A report of two cases.","authors":"F Franchi,&nbsp;L Padeletti","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Shortened return cycles after premature atrial stimulation (PAS) are commonly referred to as sinoatrial entrance block and exit delay at the sinoatrial junction or sinus-node reentries. In the 2 reported cases PAS at critical coupling intervals was followed by shortened return cycles characterized by a changed high right electrogram (and surface P waves in 1 case) and a normal sequence of atrial activation with unaltered intraatrial conduction. These changes lasted for some beats and a concomitant shorter or longer atrial cycle length was observed. Electrophysiological events furnish indirect evidence of sinoatrial pacemaker shift as a cause of incomplete interpolation in man.</p>","PeriodicalId":72971,"journal":{"name":"European journal of cardiology","volume":"12 2","pages":"95-101"},"PeriodicalIF":0.0000,"publicationDate":"1980-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of cardiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Shortened return cycles after premature atrial stimulation (PAS) are commonly referred to as sinoatrial entrance block and exit delay at the sinoatrial junction or sinus-node reentries. In the 2 reported cases PAS at critical coupling intervals was followed by shortened return cycles characterized by a changed high right electrogram (and surface P waves in 1 case) and a normal sequence of atrial activation with unaltered intraatrial conduction. These changes lasted for some beats and a concomitant shorter or longer atrial cycle length was observed. Electrophysiological events furnish indirect evidence of sinoatrial pacemaker shift as a cause of incomplete interpolation in man.

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
窦房起搏器移位引起的不完全内插。报告两个病例。
过早心房刺激(PAS)后返回周期缩短通常被称为窦房入口阻滞和窦房结或窦房结再入的窦房出口延迟。在2例报告的病例中,PAS在临界耦合时间间隔后,返回周期缩短,其特征是右高电图改变(1例为表面P波),心房激活序列正常,心房传导未改变。这些变化持续了一些心跳,同时观察到心房周期长度变短或变长。电生理事件提供了窦房起搏器移位作为不完全内插的原因的间接证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Plasma pancreatic polypeptide and gastrin in the assessment of autonomic activity in acute myocardial infarction. Effects of intrinsic sympathetic activity of beta-blockers on SA and AV nodes in man. Coronary arterial stenosis and subclavian steal in Takayasu's arteritis. Changes in 86-rubidium uptake in erythrocytes of digoxin-treated patients, in heart failure with sinus rhythm. Relationship to clinical effects. Digoxin in the elderly and in renal failure. Contribution of erythrocyte 86-rubidium uptake tests.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1