Impact of adhesive application errors on dentin bond strength of resin composite.

Biomaterial investigations in dentistry Pub Date : 2022-11-07 eCollection Date: 2022-01-01 DOI:10.1080/26415275.2022.2138405
Benjamin Michael Schärer, Anne Peutzfeldt
{"title":"Impact of adhesive application errors on dentin bond strength of resin composite.","authors":"Benjamin Michael Schärer,&nbsp;Anne Peutzfeldt","doi":"10.1080/26415275.2022.2138405","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objectives</b>: To investigate the impact of adhesive application errors on dentin bond strength of resin composite. <b>Material and Methods</b>: 165 extracted permanent human molars were ground to mid-coronal dentin. The dentin specimens were treated with one of three adhesive systems (OptiBond FL, Clearfil SE, Scotchbond Universal) either according to manufacturer's instructions or with systematic errors in the application procedure and before application of resin composite (Filtek Z250). After storage (37 °C, 100% humidity, 24 h) shear bond strength (SBS) was measured and data analysed with either one-way ANOVA followed by Tukey tests (OptiBond FL, Scotchbond Universal, control groups) or Kruskal-Wallis followed by Wilcoxon tests (Clearfil SE). Finally, the failure mode of all specimens was assessed. <b>Results</b>: With OptiBond FL and Clearfil SE omitted application (<i>p</i> ≤ 0.0001) as well as no evaporation (<i>p</i> ≤ 0.001) of the solvents in the primer significantly reduced the SBS. Omitted application of the adhesive, respectively the bond, had a negative influence on the SBS of Clearfil SE (<i>p</i> < 0.0001), but not of OptiBond FL (<i>p</i> = 0.776). With Scotchbond Universal, no evaporation of the solvents (<i>p</i> < 0.0001) as well as no light-cure (<i>p</i> = 0.0004) had a significant negative influence on the SBS. Using the adhesive systems according to manufacturer's instructions, Clearfil SE achieved significantly lower SBS than OptiBond FL and Scotchbond Universal (<i>p</i> = 0.0027). Adhesive failure at the dentin surface was generally the most frequent failure mode observed. <b>Conclusion</b>: All three adhesive systems tested were sensitive to application errors. For optimal result and longest possible durability of resin restorations, clinicians should strictly adhere to the manufacturer's instructions.</p>","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":" ","pages":"101-109"},"PeriodicalIF":0.0000,"publicationDate":"2022-11-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9648378/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/26415275.2022.2138405","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Objectives: To investigate the impact of adhesive application errors on dentin bond strength of resin composite. Material and Methods: 165 extracted permanent human molars were ground to mid-coronal dentin. The dentin specimens were treated with one of three adhesive systems (OptiBond FL, Clearfil SE, Scotchbond Universal) either according to manufacturer's instructions or with systematic errors in the application procedure and before application of resin composite (Filtek Z250). After storage (37 °C, 100% humidity, 24 h) shear bond strength (SBS) was measured and data analysed with either one-way ANOVA followed by Tukey tests (OptiBond FL, Scotchbond Universal, control groups) or Kruskal-Wallis followed by Wilcoxon tests (Clearfil SE). Finally, the failure mode of all specimens was assessed. Results: With OptiBond FL and Clearfil SE omitted application (p ≤ 0.0001) as well as no evaporation (p ≤ 0.001) of the solvents in the primer significantly reduced the SBS. Omitted application of the adhesive, respectively the bond, had a negative influence on the SBS of Clearfil SE (p < 0.0001), but not of OptiBond FL (p = 0.776). With Scotchbond Universal, no evaporation of the solvents (p < 0.0001) as well as no light-cure (p = 0.0004) had a significant negative influence on the SBS. Using the adhesive systems according to manufacturer's instructions, Clearfil SE achieved significantly lower SBS than OptiBond FL and Scotchbond Universal (p = 0.0027). Adhesive failure at the dentin surface was generally the most frequent failure mode observed. Conclusion: All three adhesive systems tested were sensitive to application errors. For optimal result and longest possible durability of resin restorations, clinicians should strictly adhere to the manufacturer's instructions.

Abstract Image

Abstract Image

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
胶粘剂应用误差对树脂复合材料牙本质结合强度的影响。
目的:探讨胶粘剂应用错误对树脂复合材料牙本质结合强度的影响。材料与方法:将165颗摘出的恒磨牙磨成中冠牙本质。根据制造商的说明,或者在应用树脂复合材料(Filtek Z250)之前,使用三种粘合剂系统(OptiBond FL, Clearfil SE, Scotchbond Universal)中的一种对牙本质样品进行处理。储存(37°C, 100%湿度,24 h)后,测量剪切粘接强度(SBS),并采用单向方差分析,然后采用Tukey检验(OptiBond FL, Scotchbond Universal,对照组)或Kruskal-Wallis检验,然后采用Wilcoxon检验(Clearfil SE)对数据进行分析。最后对各试件的破坏模式进行评估。结果:OptiBond FL和Clearfil SE省略应用(p≤0.0001)以及引物中溶剂不蒸发(p≤0.001)均显著降低SBS。遗漏粘合剂的应用对Clearfil SE的SBS有负面影响(p p = 0.776)。对于Scotchbond Universal,不蒸发溶剂(p p = 0.0004)对SBS有显著的负影响。根据制造商的说明使用粘合剂系统,Clearfil SE的SBS明显低于OptiBond FL和Scotchbond Universal (p = 0.0027)。牙本质表面的粘接剂失效是观察到的最常见的失效模式。结论:三种胶粘剂体系均对应用误差敏感。为了获得最佳效果和树脂修复体尽可能长时间的耐久性,临床医生应严格遵守制造商的说明。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
期刊最新文献
Root-filling materials for endodontic surgery: biological and clinical aspects. Silane and acid etch cross contamination of dentin and composite reduced µ-tensile bond strength. Recipient of Biomaterial Investigations in Dentistry's Young Author Award 2023. Reliability and agreement of root length measurements during orthodontic treatment in images from different CBCT machines using multiplanar reconstruction. The sealing ability of different endodontic biomaterials as an intra-orifice barrier: evaluation with high-performance liquid chromatography.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1