{"title":"Electromigration Effects in Power Grids Characterized Using an On-Chip Test Structure with Poly Heaters and Voltage Tapping Points","authors":"Chen Zhou, R. Wong, S. Wen, C. Kim","doi":"10.1109/VLSIT.2018.8510638","DOIUrl":null,"url":null,"abstract":"A 65nm test chip to study electromigration (EM) effects in power grids was taped-out and tested. A 9×9 grid was implemented using M3 and M4 metal layers which was stressed under constant current and constant voltage modes. On-chip poly heaters were employed to raise the die temperature to 350°C without damaging the chip package. A bank of transmission gates based on IO transistors were used to tap out the M3 and M4 voltages at each intersection point of the power grid. Using the test structure, we could observe for the first time, subtle behaviors of EM such as mechanical stress dependent failure locations and self-healing due to redundant current paths.","PeriodicalId":6561,"journal":{"name":"2018 IEEE Symposium on VLSI Technology","volume":"17 1","pages":"19-20"},"PeriodicalIF":0.0000,"publicationDate":"2018-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 IEEE Symposium on VLSI Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/VLSIT.2018.8510638","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
A 65nm test chip to study electromigration (EM) effects in power grids was taped-out and tested. A 9×9 grid was implemented using M3 and M4 metal layers which was stressed under constant current and constant voltage modes. On-chip poly heaters were employed to raise the die temperature to 350°C without damaging the chip package. A bank of transmission gates based on IO transistors were used to tap out the M3 and M4 voltages at each intersection point of the power grid. Using the test structure, we could observe for the first time, subtle behaviors of EM such as mechanical stress dependent failure locations and self-healing due to redundant current paths.