{"title":"Harmonizing CT Images via Physics-based Deep Neural Networks.","authors":"Mojtaba Zarei,&nbsp;Saman Sotoudeh-Paima,&nbsp;Cindy McCabe,&nbsp;Ehsan Abadi,&nbsp;Ehsan Samei","doi":"10.1117/12.2654215","DOIUrl":null,"url":null,"abstract":"<p><p>The rendition of medical images influences the accuracy and precision of quantifications. Image variations or biases make measuring imaging biomarkers challenging. The objective of this paper is to reduce the variability of computed tomography (CT) quantifications for radiomics and biomarkers using physics-based deep neural networks (DNNs). With the proposed framework, it is possible to harmonize the different renditions of a single CT scan (with variations in reconstruction kernel and dose) into an image that is in close agreement with the ground truth. To this end, a generative adversarial network (GAN) model was developed where the generator is informed by the scanner's modulation transfer function (MTF). To train the network, a virtual imaging trial (VIT) platform was used to acquire CT images, from a set of forty computational models (XCAT) serving as the patient model. Phantoms with varying levels of pulmonary disease, such as lung nodules and emphysema, were used. We scanned the patient models with a validated CT simulator (DukeSim) modeling a commercial CT scanner at 20 and 100 mAs dose levels and then reconstructed the images by twelve kernels representing smooth to sharp kernels. An evaluation of the harmonized virtual images was conducted in four different ways: 1) visual quality of the images, 2) bias and variation in density-based biomarkers, 3) bias and variation in morphological-based biomarkers, and 4) Noise Power Spectrum (NPS) and lung histogram. The trained model harmonized the test set images with a structural similarity index of 0.95±0.1, a normalized mean squared error of 10.2±1.5%, and a peak signal-to-noise ratio of 31.8±1.5 dB. Moreover, emphysema-based imaging biomarkers of LAA-950 (-1.5±1.8), Perc15 (13.65±9.3), and Lung mass (0.1±0.3) had more precise quantifications.</p>","PeriodicalId":74505,"journal":{"name":"Proceedings of SPIE--the International Society for Optical Engineering","volume":"12463 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10149034/pdf/nihms-1893883.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of SPIE--the International Society for Optical Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1117/12.2654215","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/7 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

The rendition of medical images influences the accuracy and precision of quantifications. Image variations or biases make measuring imaging biomarkers challenging. The objective of this paper is to reduce the variability of computed tomography (CT) quantifications for radiomics and biomarkers using physics-based deep neural networks (DNNs). With the proposed framework, it is possible to harmonize the different renditions of a single CT scan (with variations in reconstruction kernel and dose) into an image that is in close agreement with the ground truth. To this end, a generative adversarial network (GAN) model was developed where the generator is informed by the scanner's modulation transfer function (MTF). To train the network, a virtual imaging trial (VIT) platform was used to acquire CT images, from a set of forty computational models (XCAT) serving as the patient model. Phantoms with varying levels of pulmonary disease, such as lung nodules and emphysema, were used. We scanned the patient models with a validated CT simulator (DukeSim) modeling a commercial CT scanner at 20 and 100 mAs dose levels and then reconstructed the images by twelve kernels representing smooth to sharp kernels. An evaluation of the harmonized virtual images was conducted in four different ways: 1) visual quality of the images, 2) bias and variation in density-based biomarkers, 3) bias and variation in morphological-based biomarkers, and 4) Noise Power Spectrum (NPS) and lung histogram. The trained model harmonized the test set images with a structural similarity index of 0.95±0.1, a normalized mean squared error of 10.2±1.5%, and a peak signal-to-noise ratio of 31.8±1.5 dB. Moreover, emphysema-based imaging biomarkers of LAA-950 (-1.5±1.8), Perc15 (13.65±9.3), and Lung mass (0.1±0.3) had more precise quantifications.

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
通过基于物理的深度神经网络协调CT图像。
医学图像的再现影响定量的准确性和准确性。图像变化或偏差使得测量成像生物标志物具有挑战性。本文的目的是使用基于物理的深度神经网络(DNN)来减少放射组学和生物标志物的计算机断层扫描(CT)定量的可变性。利用所提出的框架,可以将单个CT扫描的不同呈现(重建核和剂量的变化)协调为与基本事实非常一致的图像。为此,开发了一个生成对抗性网络(GAN)模型,其中生成器由扫描仪的调制传递函数(MTF)通知。为了训练网络,使用虚拟成像试验(VIT)平台从作为患者模型的一组40个计算模型(XCAT)中获取CT图像。使用了具有不同程度肺部疾病的Phantoms,如肺结节和肺气肿。我们用经验证的CT模拟器(DukeSim)扫描患者模型,该模拟器模拟了20和100 mAs剂量水平的商用CT扫描仪,然后通过代表平滑到尖锐内核的12个内核重建图像。以四种不同的方式对协调的虚拟图像进行了评估:1)图像的视觉质量,2)基于密度的生物标志物的偏差和变化,3)基于形态学的生物标志器的偏差和变异,以及4)噪声功率谱(NPS)和肺直方图。训练后的模型使测试集图像的结构相似性指数为0.95±0.1,归一化均方误差为10.2±1.5%,峰值信噪比为31.8±1.5dB。此外,基于肺气肿的LAA-950(-1.5±1.8)、Perc15(13.65±9.3)和肺部质量(0.1±0.3)的成像生物标志物具有更精确的定量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 去求助
相关文献
Automated vessel segmentation in lung CT and CTA images via deep neural networks.
IF 3 3区 医学Journal of X-Ray Science and TechnologyPub Date : 2021-01-01 DOI: 10.3233/XST-210955
Wenjun Tan, Luyu Zhou, Xiaoshuo Li, Xiaoyu Yang, Yufei Chen, Jinzhu Yang
Liver Segmentation in CT Images Using Deep Neural Networks
IF 0 2020 28th Iranian Conference on Electrical Engineering (ICEE)Pub Date : 2020-08-04 DOI: 10.1109/ICEE50131.2020.9260809
Fatemeh Ghofrani, H. Behnam, Hamid Didari Khamseh Motlagh
A Physics-Informed Deep Neural Network for Harmonization of CT Images
IF 4.4 2区 医学IEEE Transactions on Biomedical EngineeringPub Date : 2024-07-16 DOI: 10.1109/TBME.2024.3428399
Mojtaba Zarei;Saman Sotoudeh-Paima;Cindy McCabe;Ehsan Abadi;Ehsan Samei
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
0
期刊最新文献
Errors Induced by Partial Pathlength Variations Due to Mammographic Compression in Dynamic Diffuse Optical Breast Imaging. Exploring advanced 2D acquisitions in breast tomosynthesis: T-shaped and Pentagon geometries. CDPNet: a radiomic feature learning method with epigenetic application to estimating MGMT promoter methylation status in glioblastoma. Feature Extraction of Ultrasound Radiofrequency Data for the Classification of the Peripheral Zone of Human Prostate. Assessing variability in non-contrast CT for the evaluation of stroke: The effect of CT image reconstruction conditions on AI-based CAD measurements of ASPECTS value and hypodense volume.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1