用于MEMS微电极阵列神经化学传感的氧化铱参考电极

R. K. Franklin, Matthew D. Johnson, Katharine A. Scott, J. Shim, H. Nam, D. Kipke, Richard B. Brown
{"title":"用于MEMS微电极阵列神经化学传感的氧化铱参考电极","authors":"R. K. Franklin, Matthew D. Johnson, Katharine A. Scott, J. Shim, H. Nam, D. Kipke, Richard B. Brown","doi":"10.1109/ICSENS.2005.1597971","DOIUrl":null,"url":null,"abstract":"We report for the first time a micromachined, silicon neural probe with an integrated iridium oxide (IrO) quasi reference electrode for neurochemical recordings. The probes have a 1.5 times 103 mum2 IrO reference electrode, a 1.5 times 103 mum2 Pt counter electrode, three circular Pt working electrodes, and three circular IrO electrodes for electrical recording. Several different electrode sizes (4 to 50 mum radius) were fabricated in order to study the effects of electrode size. In vitro evaluation of the probes demonstrated close correlation between results obtained using a Ag/AgCl reference electrode and the on-chip IrOx reference electrode","PeriodicalId":119985,"journal":{"name":"IEEE Sensors, 2005.","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2005-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"15","resultStr":"{\"title\":\"Iridium oxide reference electrodes for neurochemical sensing with MEMS microelectrode arrays\",\"authors\":\"R. K. Franklin, Matthew D. Johnson, Katharine A. Scott, J. Shim, H. Nam, D. Kipke, Richard B. Brown\",\"doi\":\"10.1109/ICSENS.2005.1597971\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report for the first time a micromachined, silicon neural probe with an integrated iridium oxide (IrO) quasi reference electrode for neurochemical recordings. The probes have a 1.5 times 103 mum2 IrO reference electrode, a 1.5 times 103 mum2 Pt counter electrode, three circular Pt working electrodes, and three circular IrO electrodes for electrical recording. Several different electrode sizes (4 to 50 mum radius) were fabricated in order to study the effects of electrode size. In vitro evaluation of the probes demonstrated close correlation between results obtained using a Ag/AgCl reference electrode and the on-chip IrOx reference electrode\",\"PeriodicalId\":119985,\"journal\":{\"name\":\"IEEE Sensors, 2005.\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Sensors, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2005.1597971\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2005.1597971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

我们首次报道了一种带有集成氧化铱(IrO)准参考电极的微机械硅神经探针,用于神经化学记录。探针具有1.5倍103 mum2 IrO参比电极,1.5倍103 mum2 Pt对电极,三个圆形Pt工作电极和三个用于电记录的圆形IrO电极。为了研究电极尺寸的影响,制作了几种不同尺寸的电极(4 ~ 50 μ m半径)。对探针的体外评价表明,使用Ag/AgCl参比电极和片上IrOx参比电极获得的结果密切相关
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Iridium oxide reference electrodes for neurochemical sensing with MEMS microelectrode arrays
We report for the first time a micromachined, silicon neural probe with an integrated iridium oxide (IrO) quasi reference electrode for neurochemical recordings. The probes have a 1.5 times 103 mum2 IrO reference electrode, a 1.5 times 103 mum2 Pt counter electrode, three circular Pt working electrodes, and three circular IrO electrodes for electrical recording. Several different electrode sizes (4 to 50 mum radius) were fabricated in order to study the effects of electrode size. In vitro evaluation of the probes demonstrated close correlation between results obtained using a Ag/AgCl reference electrode and the on-chip IrOx reference electrode
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Batch fabrication of micro-coils for MR spectroscopy on silicon Iridium oxide reference electrodes for neurochemical sensing with MEMS microelectrode arrays Emissions sensors for high temperature fuel cell applications Device level vacuum packaged micromachined infrared detectors on flexible substrates A CMOS time-of-flight range image sensor with gates on field oxide structure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1