用湿法化学染色识别种植体低产量问题的案例研究

Yi-Chen Lin, Sheng-Min Chen
{"title":"用湿法化学染色识别种植体低产量问题的案例研究","authors":"Yi-Chen Lin, Sheng-Min Chen","doi":"10.1109/IPFA.2014.6898131","DOIUrl":null,"url":null,"abstract":"Ion implant is very important process in semiconductor manufacturing. In this study, we discuss a problem of low yield caused by an implant related defect on a specific location and structure in the device. The paper explains how general Failure Analysis (FA) techniques such as top view analysis by Scanning Electron Microscope (SEM), Passive Voltage Contrast (PVC) and cross section by Focused Ion Beam (FIB) coupled with Transmission Electron Microscopy (TEM) are unable to identify the defect which causes the gate driver failure which in turn leads to the implantation related low yield issue. It was found that Emission Microscopy (EMMI) analysis for global isolation, followed by nano-probing for electrical characterization of the gate driver was needed. Cross section wet chemical stain technique was then used to identify the localized implant junction failure.","PeriodicalId":409316,"journal":{"name":"Proceedings of the 21th International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)","volume":"6 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2014-09-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Case study of wet chemical stain to identify implant related low yield issue\",\"authors\":\"Yi-Chen Lin, Sheng-Min Chen\",\"doi\":\"10.1109/IPFA.2014.6898131\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ion implant is very important process in semiconductor manufacturing. In this study, we discuss a problem of low yield caused by an implant related defect on a specific location and structure in the device. The paper explains how general Failure Analysis (FA) techniques such as top view analysis by Scanning Electron Microscope (SEM), Passive Voltage Contrast (PVC) and cross section by Focused Ion Beam (FIB) coupled with Transmission Electron Microscopy (TEM) are unable to identify the defect which causes the gate driver failure which in turn leads to the implantation related low yield issue. It was found that Emission Microscopy (EMMI) analysis for global isolation, followed by nano-probing for electrical characterization of the gate driver was needed. Cross section wet chemical stain technique was then used to identify the localized implant junction failure.\",\"PeriodicalId\":409316,\"journal\":{\"name\":\"Proceedings of the 21th International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)\",\"volume\":\"6 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of the 21th International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IPFA.2014.6898131\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of the 21th International Symposium on the Physical and Failure Analysis of Integrated Circuits (IPFA)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IPFA.2014.6898131","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

离子注入是半导体制造中非常重要的工艺。在这项研究中,我们讨论了由于植入物在特定位置和结构上的缺陷而导致的低成品率问题。本文解释了一般的失效分析(FA)技术,如扫描电子显微镜(SEM)的俯视图分析、无源电压对比(PVC)和聚焦离子束(FIB)结合透射电子显微镜(TEM)的横截面分析,如何无法识别导致栅极驱动器失效的缺陷,从而导致植入相关的低成品率问题。发现需要发射显微镜(EMMI)分析全局隔离,然后使用纳米探针对栅极驱动器进行电学表征。然后使用横截面湿化学染色技术来识别局部种植体连接失效。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Case study of wet chemical stain to identify implant related low yield issue
Ion implant is very important process in semiconductor manufacturing. In this study, we discuss a problem of low yield caused by an implant related defect on a specific location and structure in the device. The paper explains how general Failure Analysis (FA) techniques such as top view analysis by Scanning Electron Microscope (SEM), Passive Voltage Contrast (PVC) and cross section by Focused Ion Beam (FIB) coupled with Transmission Electron Microscopy (TEM) are unable to identify the defect which causes the gate driver failure which in turn leads to the implantation related low yield issue. It was found that Emission Microscopy (EMMI) analysis for global isolation, followed by nano-probing for electrical characterization of the gate driver was needed. Cross section wet chemical stain technique was then used to identify the localized implant junction failure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
On-chip device and circuit diagnostics on advanced technology nodes by nanoprobing Study and mechanism of static scanning laser fault isolation on embed SRAM function fail Detailed package failure analysis on short failures after high temperature storage Hot carrier injection on back biasing double-gate FinFET with 10 and 25-nm fin width Gate oxide rupture localization by photon emission microscopy with the combination of Lock-in IR-OBIRCH
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1