采用集成光环谐振器的光学MEMS压力和振动传感器

P. Pattnaik, B. Vijayaaditya, Talabattula Srinivas, A. Selvarajan
{"title":"采用集成光环谐振器的光学MEMS压力和振动传感器","authors":"P. Pattnaik, B. Vijayaaditya, Talabattula Srinivas, A. Selvarajan","doi":"10.1109/ICSENS.2005.1597779","DOIUrl":null,"url":null,"abstract":"In this paper we propose and analyse novel optical MEMS based pressure and vibration sensors utilising integrated optical ring resonators. The wavelength shift of light propagating in the resonator, located over the micro-mechanical structure, due to stress induced refractive change because of applied pressure or vibration, provides the desired sensor output. In the case of pressure sensor, as the circular diaphragm deflects due to the differential pressure, stress induced refractive index change in the waveguide lead to change in the wavelength shift providing the measure of pressure. For 1mm radius circular diaphragm with 65mum thickness, wavelength shift of 0.78 pm/kPa is obtained with a pressure range of 300 kPa. In the case of vibration sensor, the straight portion a race track resonator is located at the foot of a cantilever beam with proof mass. As the beam deflects due to vibration, stress induced refractive change in the waveguide located over the beam lead to the wavelength shift providing the measure of vibration. A wavelength shift of 3.19 pm/g in the range of 280 g for a cantilever beam of 1750 mum times 450 mum times 20 mum has been obtained. Since the wavelength of operation is around 1.55 mum, hybrid integration of source and detector is possible on the same substrate Also it is less amenable to noise as wavelength shift provides the sensor signal. This type of sensors can be used for precession instrumentation, aerospace application and other harsh environments with suitable design","PeriodicalId":119985,"journal":{"name":"IEEE Sensors, 2005.","volume":"12 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"18","resultStr":"{\"title\":\"Optical MEMS pressure and vibration sensors using integrated optical ring resonators\",\"authors\":\"P. Pattnaik, B. Vijayaaditya, Talabattula Srinivas, A. Selvarajan\",\"doi\":\"10.1109/ICSENS.2005.1597779\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this paper we propose and analyse novel optical MEMS based pressure and vibration sensors utilising integrated optical ring resonators. The wavelength shift of light propagating in the resonator, located over the micro-mechanical structure, due to stress induced refractive change because of applied pressure or vibration, provides the desired sensor output. In the case of pressure sensor, as the circular diaphragm deflects due to the differential pressure, stress induced refractive index change in the waveguide lead to change in the wavelength shift providing the measure of pressure. For 1mm radius circular diaphragm with 65mum thickness, wavelength shift of 0.78 pm/kPa is obtained with a pressure range of 300 kPa. In the case of vibration sensor, the straight portion a race track resonator is located at the foot of a cantilever beam with proof mass. As the beam deflects due to vibration, stress induced refractive change in the waveguide located over the beam lead to the wavelength shift providing the measure of vibration. A wavelength shift of 3.19 pm/g in the range of 280 g for a cantilever beam of 1750 mum times 450 mum times 20 mum has been obtained. Since the wavelength of operation is around 1.55 mum, hybrid integration of source and detector is possible on the same substrate Also it is less amenable to noise as wavelength shift provides the sensor signal. This type of sensors can be used for precession instrumentation, aerospace application and other harsh environments with suitable design\",\"PeriodicalId\":119985,\"journal\":{\"name\":\"IEEE Sensors, 2005.\",\"volume\":\"12 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE Sensors, 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICSENS.2005.1597779\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Sensors, 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICSENS.2005.1597779","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

在本文中,我们提出并分析了一种基于集成光学环形谐振器的新型光学MEMS压力和振动传感器。由于施加压力或振动引起的应力引起的折射率变化,在谐振器中传播的光的波长位移位于微机械结构上,从而提供所需的传感器输出。在压力传感器的情况下,当圆膜片由于压差而偏转时,波导中应力引起的折射率变化导致波长位移的变化,从而提供压力的测量。对于半径为1mm、厚度为65mum的圆膜片,在压力范围为300 kPa时,波长位移为0.78 pm/kPa。在振动传感器的情况下,赛道谐振器的直线部分位于具有证明质量的悬臂梁的底部。当光束由于振动而偏转时,位于光束上方的波导中的应力诱导折射变化导致波长位移,从而提供振动测量。在280 g范围内,1750 μ m × 450 μ m × 20 μ m的悬臂梁的波长位移为3.19 pm/g。由于工作波长约为1.55 μ m,因此可以在同一衬底上实现源和检测器的混合集成。此外,由于波长移位提供了传感器信号,因此不易受噪声的影响。这种类型的传感器可以用于进动仪器,航空航天应用和其他恶劣的环境,适当的设计
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optical MEMS pressure and vibration sensors using integrated optical ring resonators
In this paper we propose and analyse novel optical MEMS based pressure and vibration sensors utilising integrated optical ring resonators. The wavelength shift of light propagating in the resonator, located over the micro-mechanical structure, due to stress induced refractive change because of applied pressure or vibration, provides the desired sensor output. In the case of pressure sensor, as the circular diaphragm deflects due to the differential pressure, stress induced refractive index change in the waveguide lead to change in the wavelength shift providing the measure of pressure. For 1mm radius circular diaphragm with 65mum thickness, wavelength shift of 0.78 pm/kPa is obtained with a pressure range of 300 kPa. In the case of vibration sensor, the straight portion a race track resonator is located at the foot of a cantilever beam with proof mass. As the beam deflects due to vibration, stress induced refractive change in the waveguide located over the beam lead to the wavelength shift providing the measure of vibration. A wavelength shift of 3.19 pm/g in the range of 280 g for a cantilever beam of 1750 mum times 450 mum times 20 mum has been obtained. Since the wavelength of operation is around 1.55 mum, hybrid integration of source and detector is possible on the same substrate Also it is less amenable to noise as wavelength shift provides the sensor signal. This type of sensors can be used for precession instrumentation, aerospace application and other harsh environments with suitable design
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Batch fabrication of micro-coils for MR spectroscopy on silicon Iridium oxide reference electrodes for neurochemical sensing with MEMS microelectrode arrays Emissions sensors for high temperature fuel cell applications Device level vacuum packaged micromachined infrared detectors on flexible substrates A CMOS time-of-flight range image sensor with gates on field oxide structure
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1