{"title":"450兆赫频率下测定植入式心脏起搏器电磁兼容性的体内与体外试验方法的评价","authors":"R. Schlentz, Kristina L. Larson, K. Exworthy","doi":"10.1109/ISEMC.1976.7568729","DOIUrl":null,"url":null,"abstract":"This study evaluates two systems for measuring the susceptibility to EMI of implant able cardiac pacemakers. Each system consist ed of four parts: the pacemaker; a 450 MHz electromagnetic field; the instrumentation for monitoring pacemaker function; and the medium in which the pacemaker is placed for test. The two systems differed in the medium used; one was an empirically derived solution and the second was a canine.","PeriodicalId":296335,"journal":{"name":"IEEE 1976 International Symposium on Electromagnetic Compatibility","volume":"27 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"1976-07-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of In Vivo Versus In Vitro Test Methods for the Determination of Electromagnetic Compatibility of Implantable Cardiac Pacemakers at 450 MHz\",\"authors\":\"R. Schlentz, Kristina L. Larson, K. Exworthy\",\"doi\":\"10.1109/ISEMC.1976.7568729\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study evaluates two systems for measuring the susceptibility to EMI of implant able cardiac pacemakers. Each system consist ed of four parts: the pacemaker; a 450 MHz electromagnetic field; the instrumentation for monitoring pacemaker function; and the medium in which the pacemaker is placed for test. The two systems differed in the medium used; one was an empirically derived solution and the second was a canine.\",\"PeriodicalId\":296335,\"journal\":{\"name\":\"IEEE 1976 International Symposium on Electromagnetic Compatibility\",\"volume\":\"27 1\",\"pages\":\"0\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1976-07-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE 1976 International Symposium on Electromagnetic Compatibility\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.1976.7568729\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE 1976 International Symposium on Electromagnetic Compatibility","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.1976.7568729","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Evaluation of In Vivo Versus In Vitro Test Methods for the Determination of Electromagnetic Compatibility of Implantable Cardiac Pacemakers at 450 MHz
This study evaluates two systems for measuring the susceptibility to EMI of implant able cardiac pacemakers. Each system consist ed of four parts: the pacemaker; a 450 MHz electromagnetic field; the instrumentation for monitoring pacemaker function; and the medium in which the pacemaker is placed for test. The two systems differed in the medium used; one was an empirically derived solution and the second was a canine.