研究壁厚对 PFA 超声波流量传感器接收信号的影响

IF 1.6 4区 工程技术 Q3 INSTRUMENTS & INSTRUMENTATION Sensor Review Pub Date : 2024-03-14 DOI:10.1108/sr-03-2023-0055
Liang Hu, Chengwei Liu, Rui Su, Weiting Liu
{"title":"研究壁厚对 PFA 超声波流量传感器接收信号的影响","authors":"Liang Hu, Chengwei Liu, Rui Su, Weiting Liu","doi":"10.1108/sr-03-2023-0055","DOIUrl":null,"url":null,"abstract":"<h3>Purpose</h3>\n<p>In a coaxial ultrasonic flow sensor (UFS), wall thickness is a vital parameter of the measurement tube, especially those with small inner diameters. The paper aims to investigate the influence of wall thickness on the transient signal characteristics in an UFS.</p><!--/ Abstract__block -->\n<h3>Design/methodology/approach</h3>\n<p>First, the problem was researched experimentally using a series of measurement tubes with different wall thicknesses. Second, a finite element method–based model in the time domain was established to validate the experimental results and further discussion. Finally, the plane wave assumption and oblique incident theory were used to analyze the wave propagation in the tube, and an idea of wave packet superposition was proposed to reveal the mechanism of the influence of wall thickness.</p><!--/ Abstract__block -->\n<h3>Findings</h3>\n<p>Both experimental and simulated results showed that the signal amplitude decreased periodically as the wall thickness increased, and the corresponding waveform varied dramatically. Based on the analysis of wave propagation in the measurement tube, a formula concerning the phase difference between wave packets was derived to characterize the signal variation.</p><!--/ Abstract__block -->\n<h3>Originality/value</h3>\n<p>This paper provides a new and explicit explanation of the influence of wall thickness on the transient signal in a co-axial UFS. Both experimental and simulated results were presented, and the mechanism was clearly described.</p><!--/ Abstract__block -->","PeriodicalId":49540,"journal":{"name":"Sensor Review","volume":"24 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2024-03-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation on the influence of wall thickness on the reception signal in a PFA-made ultrasonic flow sensor\",\"authors\":\"Liang Hu, Chengwei Liu, Rui Su, Weiting Liu\",\"doi\":\"10.1108/sr-03-2023-0055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<h3>Purpose</h3>\\n<p>In a coaxial ultrasonic flow sensor (UFS), wall thickness is a vital parameter of the measurement tube, especially those with small inner diameters. The paper aims to investigate the influence of wall thickness on the transient signal characteristics in an UFS.</p><!--/ Abstract__block -->\\n<h3>Design/methodology/approach</h3>\\n<p>First, the problem was researched experimentally using a series of measurement tubes with different wall thicknesses. Second, a finite element method–based model in the time domain was established to validate the experimental results and further discussion. Finally, the plane wave assumption and oblique incident theory were used to analyze the wave propagation in the tube, and an idea of wave packet superposition was proposed to reveal the mechanism of the influence of wall thickness.</p><!--/ Abstract__block -->\\n<h3>Findings</h3>\\n<p>Both experimental and simulated results showed that the signal amplitude decreased periodically as the wall thickness increased, and the corresponding waveform varied dramatically. Based on the analysis of wave propagation in the measurement tube, a formula concerning the phase difference between wave packets was derived to characterize the signal variation.</p><!--/ Abstract__block -->\\n<h3>Originality/value</h3>\\n<p>This paper provides a new and explicit explanation of the influence of wall thickness on the transient signal in a co-axial UFS. Both experimental and simulated results were presented, and the mechanism was clearly described.</p><!--/ Abstract__block -->\",\"PeriodicalId\":49540,\"journal\":{\"name\":\"Sensor Review\",\"volume\":\"24 1\",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-03-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Sensor Review\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1108/sr-03-2023-0055\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sensor Review","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1108/sr-03-2023-0055","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

目的 在同轴超声波流量传感器(UFS)中,壁厚是测量管的一个重要参数,尤其是那些内径较小的测量管。本文旨在研究壁厚对 UFS 瞬态信号特性的影响。首先,使用一系列不同壁厚的测量管对该问题进行了实验研究。其次,建立了基于有限元法的时域模型,以验证实验结果和进一步讨论。最后,利用平面波假设和斜入射理论分析了波在管内的传播,并提出了波包叠加的思想,揭示了壁厚的影响机理。实验和模拟结果都表明,随着壁厚的增加,信号幅度呈周期性下降,相应的波形也发生了很大变化。基于对测量管中波传播的分析,推导出了一个有关波包之间相位差的公式,以描述信号变化的特征。文中给出了实验和模拟结果,并清楚地描述了其中的机理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Investigation on the influence of wall thickness on the reception signal in a PFA-made ultrasonic flow sensor

Purpose

In a coaxial ultrasonic flow sensor (UFS), wall thickness is a vital parameter of the measurement tube, especially those with small inner diameters. The paper aims to investigate the influence of wall thickness on the transient signal characteristics in an UFS.

Design/methodology/approach

First, the problem was researched experimentally using a series of measurement tubes with different wall thicknesses. Second, a finite element method–based model in the time domain was established to validate the experimental results and further discussion. Finally, the plane wave assumption and oblique incident theory were used to analyze the wave propagation in the tube, and an idea of wave packet superposition was proposed to reveal the mechanism of the influence of wall thickness.

Findings

Both experimental and simulated results showed that the signal amplitude decreased periodically as the wall thickness increased, and the corresponding waveform varied dramatically. Based on the analysis of wave propagation in the measurement tube, a formula concerning the phase difference between wave packets was derived to characterize the signal variation.

Originality/value

This paper provides a new and explicit explanation of the influence of wall thickness on the transient signal in a co-axial UFS. Both experimental and simulated results were presented, and the mechanism was clearly described.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Sensor Review
Sensor Review 工程技术-仪器仪表
CiteScore
3.40
自引率
6.20%
发文量
50
审稿时长
3.7 months
期刊介绍: Sensor Review publishes peer reviewed state-of-the-art articles and specially commissioned technology reviews. Each issue of this multidisciplinary journal includes high quality original content covering all aspects of sensors and their applications, and reflecting the most interesting and strategically important research and development activities from around the world. Because of this, readers can stay at the very forefront of high technology sensor developments. Emphasis is placed on detailed independent regular and review articles identifying the full range of sensors currently available for specific applications, as well as highlighting those areas of technology showing great potential for the future. The journal encourages authors to consider the practical and social implications of their articles. All articles undergo a rigorous double-blind peer review process which involves an initial assessment of suitability of an article for the journal followed by sending it to, at least two reviewers in the field if deemed suitable. Sensor Review’s coverage includes, but is not restricted to: Mechanical sensors – position, displacement, proximity, velocity, acceleration, vibration, force, torque, pressure, and flow sensors Electric and magnetic sensors – resistance, inductive, capacitive, piezoelectric, eddy-current, electromagnetic, photoelectric, and thermoelectric sensors Temperature sensors, infrared sensors, humidity sensors Optical, electro-optical and fibre-optic sensors and systems, photonic sensors Biosensors, wearable and implantable sensors and systems, immunosensors Gas and chemical sensors and systems, polymer sensors Acoustic and ultrasonic sensors Haptic sensors and devices Smart and intelligent sensors and systems Nanosensors, NEMS, MEMS, and BioMEMS Quantum sensors Sensor systems: sensor data fusion, signals, processing and interfacing, signal conditioning.
期刊最新文献
Multi-sensor integration on one microfluidics chip for single-stranded DNA detection Advances in drift compensation algorithms for electronic nose technology A novel Au-NPs/DBTTA nanocomposite-based electrochemical sensor for the detection of ascorbic acid (AA) A step length estimation method based on frequency domain feature analysis and gait recognition for pedestrian dead reckoning Liquid viscosity measurement based on disk-shaped electromechanical resonator
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1