心电图偏移校正对室性早搏起源定位的重要性

IF 1 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION Measurement Science Review Pub Date : 2022-10-13 DOI:10.2478/msr-2022-0031
J. Svehlíková, A. Přibilová, J. Zelinka, Beáta Ondrusová, K. Kromkova, P. Hlivak, R. Hatala, M. Tysler
{"title":"心电图偏移校正对室性早搏起源定位的重要性","authors":"J. Svehlíková, A. Přibilová, J. Zelinka, Beáta Ondrusová, K. Kromkova, P. Hlivak, R. Hatala, M. Tysler","doi":"10.2478/msr-2022-0031","DOIUrl":null,"url":null,"abstract":"Abstract In this study, the inverse solution with a single dipole was computed to localize the premature ventricular contraction (PVC) origin from long term multiple leads ECG measurements on fourteen patients. The stability of the obtained results was studied with respect to the preprocessing of signals used as an input to the inverse solution and the complexity of the torso model. Two methods were used for the baseline drift removal. After an averaging of the heartbeats, the influence of the retention or elimination of the remaining offset at the beginning of the PVC signal was examined. The inverse computations were performed using both homogeneous and inhomogeneous patient-specific torso models. It was shown that the remaining offset in the averaged signals at the beginning of the PVC signal had the most significant impact on the stability of the resulting position within the ventricles. Its elimination stabilizes the location of the results, decreases the sensitivity to the torso model complexity and decreases the sensitivity to the primary baseline drift removal method. The additional offset correction decreased the mean distance between the results for all patients from 17-18 mm to 1-2 mm, regardless of the baseline drift removal method or the torso model complexity.","PeriodicalId":49848,"journal":{"name":"Measurement Science Review","volume":"22 1","pages":"246 - 252"},"PeriodicalIF":1.0000,"publicationDate":"2022-10-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"The Importance of ECG Offset Correction for Premature Ventricular Contraction Origin Localization from Clinical Data\",\"authors\":\"J. Svehlíková, A. Přibilová, J. Zelinka, Beáta Ondrusová, K. Kromkova, P. Hlivak, R. Hatala, M. Tysler\",\"doi\":\"10.2478/msr-2022-0031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract In this study, the inverse solution with a single dipole was computed to localize the premature ventricular contraction (PVC) origin from long term multiple leads ECG measurements on fourteen patients. The stability of the obtained results was studied with respect to the preprocessing of signals used as an input to the inverse solution and the complexity of the torso model. Two methods were used for the baseline drift removal. After an averaging of the heartbeats, the influence of the retention or elimination of the remaining offset at the beginning of the PVC signal was examined. The inverse computations were performed using both homogeneous and inhomogeneous patient-specific torso models. It was shown that the remaining offset in the averaged signals at the beginning of the PVC signal had the most significant impact on the stability of the resulting position within the ventricles. Its elimination stabilizes the location of the results, decreases the sensitivity to the torso model complexity and decreases the sensitivity to the primary baseline drift removal method. The additional offset correction decreased the mean distance between the results for all patients from 17-18 mm to 1-2 mm, regardless of the baseline drift removal method or the torso model complexity.\",\"PeriodicalId\":49848,\"journal\":{\"name\":\"Measurement Science Review\",\"volume\":\"22 1\",\"pages\":\"246 - 252\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2022-10-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement Science Review\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2478/msr-2022-0031\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science Review","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2478/msr-2022-0031","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 4

摘要

摘要在本研究中,通过计算单偶极子的逆解来定位14名患者的长期多导联心电图测量中的室性早搏(PVC)起源。关于用作反解输入的信号的预处理和躯干模型的复杂性,研究了所获得结果的稳定性。基线漂移去除采用了两种方法。在平均心跳之后,检查在PVC信号开始时保留或消除剩余偏移的影响。使用均质和非均质患者特定躯干模型进行反向计算。结果表明,在PVC信号开始时平均信号中的剩余偏移对心室内最终位置的稳定性具有最显著的影响。它的消除稳定了结果的位置,降低了对躯干模型复杂性的敏感性,并降低了对主要基线漂移去除方法的敏感性。无论基线漂移消除方法或躯干模型的复杂性如何,额外的偏移校正都将所有患者的结果之间的平均距离从17-18 mm降低到1-2 mm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
The Importance of ECG Offset Correction for Premature Ventricular Contraction Origin Localization from Clinical Data
Abstract In this study, the inverse solution with a single dipole was computed to localize the premature ventricular contraction (PVC) origin from long term multiple leads ECG measurements on fourteen patients. The stability of the obtained results was studied with respect to the preprocessing of signals used as an input to the inverse solution and the complexity of the torso model. Two methods were used for the baseline drift removal. After an averaging of the heartbeats, the influence of the retention or elimination of the remaining offset at the beginning of the PVC signal was examined. The inverse computations were performed using both homogeneous and inhomogeneous patient-specific torso models. It was shown that the remaining offset in the averaged signals at the beginning of the PVC signal had the most significant impact on the stability of the resulting position within the ventricles. Its elimination stabilizes the location of the results, decreases the sensitivity to the torso model complexity and decreases the sensitivity to the primary baseline drift removal method. The additional offset correction decreased the mean distance between the results for all patients from 17-18 mm to 1-2 mm, regardless of the baseline drift removal method or the torso model complexity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
相关文献
二甲双胍通过HDAC6和FoxO3a转录调控肌肉生长抑制素诱导肌肉萎缩
IF 8.9 1区 医学Journal of Cachexia, Sarcopenia and MusclePub Date : 2021-11-02 DOI: 10.1002/jcsm.12833
Min Ju Kang, Ji Wook Moon, Jung Ok Lee, Ji Hae Kim, Eun Jeong Jung, Su Jin Kim, Joo Yeon Oh, Sang Woo Wu, Pu Reum Lee, Sun Hwa Park, Hyeon Soo Kim
具有疾病敏感单倍型的非亲属供体脐带血移植后的1型糖尿病
IF 3.2 3区 医学Journal of Diabetes InvestigationPub Date : 2022-11-02 DOI: 10.1111/jdi.13939
Kensuke Matsumoto, Taisuke Matsuyama, Ritsu Sumiyoshi, Matsuo Takuji, Tadashi Yamamoto, Ryosuke Shirasaki, Haruko Tashiro
封面:蛋白质组学分析确定IRSp53和fastin是PRV输出和直接细胞-细胞传播的关键
IF 3.4 4区 生物学ProteomicsPub Date : 2019-12-02 DOI: 10.1002/pmic.201970201
Fei-Long Yu, Huan Miao, Jinjin Xia, Fan Jia, Huadong Wang, Fuqiang Xu, Lin Guo
来源期刊
Measurement Science Review
Measurement Science Review INSTRUMENTS & INSTRUMENTATION-
CiteScore
2.00
自引率
11.10%
发文量
37
审稿时长
4.8 months
期刊介绍: - theory of measurement - mathematical processing of measured data - measurement uncertainty minimisation - statistical methods in data evaluation and modelling - measurement as an interdisciplinary activity - measurement science in education - medical imaging methods, image processing - biosignal measurement, processing and analysis - model based biomeasurements - neural networks in biomeasurement - telemeasurement in biomedicine - measurement in nanomedicine - measurement of basic physical quantities - magnetic and electric fields measurements - measurement of geometrical and mechanical quantities - optical measuring methods - electromagnetic compatibility - measurement in material science
期刊最新文献
Accurate Solution of Adjustment Models of 3D Control Network Metamaterial Inspired Stub-Incorporated Quad-Band Diamond Shaped Monopole Antenna for Satellite and Wireless Application Influence of the Electrical Test Setup on the Voltage Gain Measurement of an Unloaded Rosen-Type Piezoelectric Transformer Vibrating in the First Three Modes ECG Arrhythmia Measurement and Classification for Portable Monitoring Adaptive Proportional Derivative Control for Magnetic Bearing in Full Maglev Left Ventricular Assist Device
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1