Boogyo Sim, Keunwoo Kim, Taein Shin, Hyunwook Park, Seongguk Kim, Daehwan Lho, Keeyoung Son, Kyubong Kong, Seungtaek Jeong, Seonguk Choi, Jihun Kim, Joungho Kim
{"title":"Intra-pair Skew Impact Analysis of High-speed Cables for HDMI Interface","authors":"Boogyo Sim, Keunwoo Kim, Taein Shin, Hyunwook Park, Seongguk Kim, Daehwan Lho, Keeyoung Son, Kyubong Kong, Seungtaek Jeong, Seonguk Choi, Jihun Kim, Joungho Kim","doi":"10.1109/EPEPS53828.2022.9947140","DOIUrl":null,"url":null,"abstract":"In this paper, the coaxial and shielded-twisted pair (STP) cables with intra-pair skew was analyzed by frequency domain analysis method by the equations in close-to-real intra-pair skew setup for high definition multimedia interface (HDMI) interface. For the high-speed interface, the intra-pair skew has become critical factor in terms of signal integrity. Heretofore, the intra-pair skew has not been commonly investigated in frequency domain for the high-speed data rate. To verify the intra-pair skew impact on the high-speed interface, the intra-pair skew location was distributed in the coaxial and STP cable assemblies for the real cable setup. Next, the skew impact was verified using frequency domain analysis and the eye-diagram. As the result, by the frequency-domain analysis, the differential loss and the mode conversion of coaxial cable assembly deteriorated due to the intra-pair skew, but STP did not deteriorate. Furthermore, the eye-diagram of the coaxial cable assembly with skew had smaller opening than without any skew, but of STP had little change.","PeriodicalId":284818,"journal":{"name":"2022 IEEE 31st Conference on Electrical Performance of Electronic Packaging and Systems (EPEPS)","volume":"54 1","pages":"0"},"PeriodicalIF":0.0000,"publicationDate":"2022-10-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 IEEE 31st Conference on Electrical Performance of Electronic Packaging and Systems (EPEPS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EPEPS53828.2022.9947140","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
In this paper, the coaxial and shielded-twisted pair (STP) cables with intra-pair skew was analyzed by frequency domain analysis method by the equations in close-to-real intra-pair skew setup for high definition multimedia interface (HDMI) interface. For the high-speed interface, the intra-pair skew has become critical factor in terms of signal integrity. Heretofore, the intra-pair skew has not been commonly investigated in frequency domain for the high-speed data rate. To verify the intra-pair skew impact on the high-speed interface, the intra-pair skew location was distributed in the coaxial and STP cable assemblies for the real cable setup. Next, the skew impact was verified using frequency domain analysis and the eye-diagram. As the result, by the frequency-domain analysis, the differential loss and the mode conversion of coaxial cable assembly deteriorated due to the intra-pair skew, but STP did not deteriorate. Furthermore, the eye-diagram of the coaxial cable assembly with skew had smaller opening than without any skew, but of STP had little change.